|
COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 10,1996 PSA#1676USMC Regional Contracting Office (Far East), PSC 557, Box 2000, FPO AP
96379-2000 42 -- COMPRESSORS, ATTACHMENTS AND PARTS SOL M67400-96-R-0001 DUE
092396. Contact: Rick Maberry, 011-81-6117-45-1504 or 3974; FAX
011-81-988-93-6024/011-81-988-92-0551/011-81-988-93-3983 Contracting
Officer: P.A. Darrah. This is a combined synopsis/solicitation for
commercial items prepared in accordance with the format in FAR Subpart
12.6, as supplemented with additional information included in this
notice. This announcement constitutes the only solicitation; proposals
are being requested and a written solicitation will not be issued.
This solicitation M67400-96-R-0001 is issued as a Request for Proposal
(RFP). The solicitation document and incorporated provisions and
clauses are those in effect through Federal Acquisition Circular 90-37.
This procurement is unrestricted. CLIN 0001 Compressor, 2 EA, 208 VAC,
3 phase, 60 cycle motor. Configuration for vertical permanent
installation. D.F.M. rating of 20.4.The Compressor will come with a
gauge panel which has individual pressure gauges for all stages and the
oil pressure; and hour meter for logging operational run time and
maintaining a maintenance schedule; a high temperature switch which
will shut down the system if there is a problem with excessive heat; a
low oil pressure switch which will shut down the system due to low oil
pressure; an automatic condensate drain which will automatically dump
condensate as required by the system; an automatic start/stop switch
that will start the system at a specified low pressure and stop the
system at a predetermined high air pressure. Capable of processing a
minimum of 80,000 cubic feet of air between cartridge changes.
Compressor shall have one purification filter system consisting of the
following main components: (1) Coalescing oil and water separator. (2)
Two purification chambers with replaceable purification cartridges. (3)
Electronic moisture monitoring system. (4) Panel for mounting the
system. The high pressure purification chambers must have a working
minimum pressure of 5,000 PSIG. The design of the cartridge pressure
chambers must eliminate the possibility of operating the system without
purification cartridges installed or with improperly installed
cartridges. CLIN 0002 Compressor; 2 EA, 208 VAC, 3 phase, 60 cycle
motor, deployable, self contained, with heavy duty locking wheels,
lifting rings, a flexible high pressure air line, an electric power
cord, heavy duty frame. Compressors must be capable of being readily
configured for operation in a lag/lead configuration with compressors
listed in (CLIN 0001). Minimum C.F.M. rating of 20.4. The compressor
shall have a gauge panel which has individual pressure gauges for all
stages and the oil pressure; an hour meter for logging operational run
time and maintaining a maintenance schedule; a high temperature switch
which will shut down the system if there is a problem with excessive
heat; a low oil pressure switch which will shut down the system due to
low oil pressure; an automatic condensate drain which will
automatically dump condensate as required by the system; an automatic
start/stop switch that will start the system at a predetermined low air
pressure and stop the system at a predetermined high air pressure.
Capable of processing a minimum of 80,000 cubic feet of air between
cartridge changes. The compressor shall have one purification system.
The system shall come with the following minimum main components: (1)
Coalescing oil and water separator. (2) Two purification chambers with
replaceable purification cartridges. (3) Electronic moisture
monitoring system. (4) Panel for mounting the system. The high pressure
purification chambers must have a working minimum pressure of 5,000
PSIG. the design of the cartridge pressure chambers must prevent the
possibility of operating the system without purification cartridges
installed or with improperly installed cartridges. CLIN 0003 Fill
station; 4 EA, capable of filling six air bottles simultaneously. Two
separate distribution systems shall consist of 2 fill station panels
each with the following minimum features: (1) Inlet/supply pressure
gauge. (2) Adjustable pressure reducing regulator. (3) Outlet pressure
gauge. (4) 6 control valves, one for each fill whip. (5) 6 individual
pressure gauges. All control valves are on the panel next to
corresponding gauge. Each 4 foot whip comes with a scuba yoke and bleed
valve so that the whip pressure is relieved between tank fills. The
pressure reducing regulator adjusts from 0 to 4500 PSI with an
operation set pressure relief valve set. CLIN 0004 Four storage vessel
racks wall mounted, each capable of holding (4) vertical storage
vessels (total of 16 vessels). Storage vessels shall conform to
American Society of Mechanical Engineers (ASME) with a minimum of 439
cubic foot and 5250 PSI.. The vessels desired sizes are 55'' tall with
a diameter of 9.5''. The system shall include all cylinder valves,
safety relief valves, and all necessary plumbing, hardware, and
mounting racks. The storage vessels shall never require hydrostatic
testing. This system shall be capable of receiving a minimum of 3500
cubic feet of air in storage for immediate distribution. CLIN 0005
Oxygen booster system with pump, 2 EA, capable of completely draining
the oxygen supply bottles. The system shall come with the following
minimum components: (1) An air drive supply adjustable reducing
regulator with pressure gauges. (2) oxygen booster. (3) Pump. The
booster shall pump from high or medium pressure sources. (4) Mounted in
a deluxe roll cage assembly. The booster shall be rated for a minimum
continuous compression ratios of over 15:1, and intermittent to 40:1.
It shall have a pneumatic control package which continually monitors
both inlet and outlet receiver pressure, stopping the booster
automatically when desired outlet or minimum inlet pressure is reached.
The supply drive air will come from the high pressure system after
purification. CLIN 0006 Oil, 20 GAL, manufacturer's standard, for
maintenance of the air system. CLIN 0007 Provide preventative
maintenance components parts for a period of 2 years ensuring
compatibility with all system components of offered products and
compliance with United States Navy NAVSEA and 3M (Material Maintenance
Management) directive and orders. Final marking instructions will be
provided at the time of award. All commodities shall come with the
standard commercial warranty, and any extended warranty offered to the
general public shall also be offered to the Government. FAR 52.212-1,
Instructions to Offerors - Commercial Items (Oct 1995) applies to this
acquisition as does FAR 52.212-2, Evaluation - Commercial Items (Oct
1995). The following factors will be used to evaluate offers: (1)
Technical Compliance with Specifications. Offerors shall submit
descriptive literature of the items being offered in sufficient detail
to evaluate compliance with the requirements in the technical
specifications. (2) Past Performance. Offeror shall submit the
following information concerning similar services furnished during the
past two (2) years: Name, address, telephone number, point of contact,
total dollar amount of contracts or orders from Federal, State, Local
Government agencies or private companies in which the offer has
performed similar services. Specific information pertaining to
experience with United States Military Diving, Closed Circuit Oxygen
rebreathers (DRAGER) diving, and Naval/Marine Special Operations is
encouraged while performing those contractors or orders and offerors'
corrective action used to resolve those difficulties. (3) Price. The
Government intends to evaluate proposals and may award a contract
without discussions, therefore, offerors are encouraged to submit their
best offer from a cost or price standpoint. Price is an important
evaluation factor for award; however, technical compliance with
specification and past performance factors, when combined, are
significantly more important than price. The offeror is required to
submit a completed copy of the provision at FAR 52.212-3, Offeror
Representations and Certifications - Commercial Items (Oct 1995), with
its offer. FAR 52.212-5, Contract Terms and Conditions Required to
Implement Statutes or Executive Orders - Commercial Items (JAN 1996) is
incorporated in this solicitation. The following additional clauses
apply to this acquisition. FAR Clause 52.212-4, Contract Terms and
Conditions - Commercial Items (Oct 1995); FAR 52.203-6, Restrictions on
Subcontractor Sales to the Government, with Alternate I (41 U.S.C. 253g
and 10 U.S.C. 2402); FAR 52.203-10, Price or Fee Adjustment for Illegal
or Improper Activity (41 U.S.C. 423); FAR 52.222-35, Affirmative Action
for Special Disabled and Vietnam Era Veterans (38 U.S.C, 4212); FAR
52.222-37, Employment Reports on Special Disabled Veterans and Veterans
of the Vietnam Era (38 U.S.C. 4212). FAR 52.211-17, Delivery of Excess
Quantities (Sep 1989), FAR 52.214-21 Descriptive Literature (APR
1984), and FAR 52.215-18 Facsimile Proposals (DEC 1989) are also
incorporated in this solicitation. CLINS 0001 through 0007 must be
approved products in accordance with Operations, Naval Instruction
(OPNAVINST) 3150.27A by the Naval Sea Support Center, Pacific Code 910,
P.O. Box 85548, San Diego, CA 92186-5548 or the Naval Sea Support
Center, Atlantic code 922B St. Juliens Creek Annex, Portsmouth, VA
23702-5098. Offerors shall ensure all products provided meet UNITED
STATES NAVY NAVSEA Standards. The Naval Sea Systems Command (NAVSEA) in
conjunction with the Naval Safety Center will have final technical
approval on the products offered in response to this solicitation.
Required delivery time is thirty (30) days after notification of award
to Lathrop, California. Proposals will be accepted by either U.S. or
foreign mail and sent to The Regional Contracting Office, PSC 557 Box
2000, FPO AP 96379-2000 or by facsimile. There is no overnight delivery
from the United States to Okinawa, Japan available through the United
States postal service. Offerors are advised to take this into
consideration when mailing their offers. Offers must arrive NLT 1500
hours, Japan Standard Time on September 23, 1996. For additional
information, contact Rick Maberry at 011-81-6117-45-1504 or FAX
011-81-988-93-6024/011-81-988-92-0551/011-81-988-93-3983. All
responsible sources may submit an offer which will be considered.
(249) Loren Data Corp. http://www.ld.com (SYN# 0231 19960909\42-0001.SOL)
42 - Firefighting, Rescue and Safety Equipment Index Page
|
|