COMMERCE BUSINESS DAILY ISSUE OF OCTOBER 7,1996 PSA#1695Naval Air Warfare Center AD, Contracts Dept. Code 233, Bldg 129-2,
Lakehurst, NJ 08733-5083. 49 -- GENERATOR TEST STAND SOL N68335-97-R-0015 DUE 111396 POC Lt Mike
Hopkins Code 2132MH, (908) 323-1274. Buyer/Contracting Officer Francis
Hufnell. NAWCAD intends to procure 1 EA Generator Test Stand Avtron
Manufacturing Part Number K838-100 or an equivalent unit meeting or
exceeding the following salient characteristics: Drive Motor: DC:100HP,
1750/3100 RPM, 500 VDC Armature, 300 VDC Field, drip proof, 40 Deg. C
ambient, forced ventilation, integral blower, isolated over temperature
switch, overload 150 HP for 60 seconds 4 times per hour; Gearbox: Speed
increaser, ratio 1:5 100 HP continuous 8750 to 15,500 RPM at output
shaft. 150% overload for one minute. Reversible. Acceleration rate of
10 to 1000 RPM/sec. Maximum noise level 94 db (''A scale, ref 1
microbar, microphone 36'' away in any direction). Dynamic balance;
precision class. Ambient 10 to 50 Deg C.; Gearbox Lube System: 10
micron nominal filter, Oil to air heat exchanger, 5 gallon reservoir,
pressure and temperature protection, pressure gauge, temperature guage,
oil level guage, clogged filter indicator. Pulse Generator: Zero speed,
bi-directional, single ended. Output: 2 phase quadrature square wave,
240 pulses per revolution, 0-20 kilohertz, 0-5000 RPM, -20 to 180 Deg.
F ambient. DC Drive System: Embedded controller, three phase
four-quadrant power converter which operates at 47 to 63 Hz. Controls:
speed, acceleration, direction, and torque. Protection include: motor
over current, stall detection, power loss, phase loss, over/under
voltage, motor overspeed, motor over acceleration, field loss, motor
thermal protection. Speed regulation: within 0.1% of base speed from no
load to rated continuous load (after a 30 minute warm up). Drive
Isolation Transformer: UL listed, CSA certified, 118 KVA, heavy duty
ventilated NEMA 1 enclosure, free-standing, dry-type (may be floor or
wall mounted). Voltage tap: 5% FCAN & FCBN. 220 Deg. C insulation. 4-6%
impedance. Meets UL and CSA short circuit withstand capacity. System
Circuit Breaker: Three-pole, 600 VAC, UL rated enclosure. Thermal trip,
magnetic trip and external shunt trip (Emergency Stop). DC Load Bank:
30 VDC, 1000 Amp (30kw). Integral control/metering panel. Cold to hot
resistance: 1% Max. Resistors calibrated to +/2%. Cooling air loss
protection. Integral Metering: DC Volts, Amps @0.5% of full scale. DC
Starter Power Supply. 0-28 VDC, 0-1400 Amps (adjustable). Free standing
NEMA 1 enclosure. AC circuit breaker, fused semiconductor protection,
overload protection, 150% overload capacity (1minute). Regulation:
+/-1% (current and voltage). Output ripple: 1% RMS (at rated load).
Integral Meters: DC volts: +/-2% of full scale; DC amps: +/-2% of full
scale.Locked Rotor Torque Components: Easy snap-in change from no-load
speed to locked rotor test. Torque transducer: 0-50lbs. ft. (0-600 lbs.
Inch), 2% of full scale (including meter). Speed metering: 0-9, 999
RPM, +/-2 RPM. Dynamic Torque Components: Hollow Reaction Torque Sensor
(no moving parts, no bearings to wear out), 0-500 lbs.in, 2% of full
scale (including meter). Analog feedback to DC Drive for Torque
Setpoint testing. Testing can be accomplished two waysL set torque
setpoint and adjust DC starter voltage, or set DC starter voltage and
adjust torque control. Drive Controller and Metering: Microprocessor-
based allowing control and/or display of ramp rate, overspeed
protective setpoint, speed setpoint, actual speed display (resolution
1 RPM), fault display (drive fault, E-stop), torque setpoint and actual
torque display. Aux Frequency: 0-2Khz, 0.1% of reading. Aux AC Volts:
0-200 V, .0.2% of reading. Demag Volts: 0-200 V, 0.2% of reading (Demag
0-40 V Max). Field current: 0-20 A, 0.3% of reading. Field Volts:
0-199.9 V, 0.05% of reading, Aux DC Volts: 0-199.9 V, 0.05% of reading.
Temperature: 0-1562 Deg. F, +/-2.7 Deg. F. Portable Cooling: 3 HP
motor, 0-16 inches of water pressure guage, butterfly valve. Blower:
power cord, 4 foot by 4 inch dia. flexible hose; Generator Mounting:
Mounting adapter to interface generator test stand with DC generator;
Adapter: Bell Helicopter Textron Inc. P/N 214-175-150-105. As part of
this procurement NAWCAD also intends to procure installation, power
checks, start-up services, calibration verifications, training, and
technical support for the generator test stand to be provided in
country Taiwan. Additionally, the NAWCAD intends to procure spare parts
for the generator test stand. Request copies in writing or by facsimile
(908) 323-2165. (0277) Loren Data Corp. http://www.ld.com (SYN# 0232 19961004\49-0001.SOL)