Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF OCTOBER 7,1996 PSA#1695

Naval Air Warfare Center AD, Contracts Dept. Code 233, Bldg 129-2, Lakehurst, NJ 08733-5083.

49 -- GENERATOR TEST STAND SOL N68335-97-R-0015 DUE 111396 POC Lt Mike Hopkins Code 2132MH, (908) 323-1274. Buyer/Contracting Officer Francis Hufnell. NAWCAD intends to procure 1 EA Generator Test Stand Avtron Manufacturing Part Number K838-100 or an equivalent unit meeting or exceeding the following salient characteristics: Drive Motor: DC:100HP, 1750/3100 RPM, 500 VDC Armature, 300 VDC Field, drip proof, 40 Deg. C ambient, forced ventilation, integral blower, isolated over temperature switch, overload 150 HP for 60 seconds 4 times per hour; Gearbox: Speed increaser, ratio 1:5 100 HP continuous 8750 to 15,500 RPM at output shaft. 150% overload for one minute. Reversible. Acceleration rate of 10 to 1000 RPM/sec. Maximum noise level 94 db (''A scale, ref 1 microbar, microphone 36'' away in any direction). Dynamic balance; precision class. Ambient 10 to 50 Deg C.; Gearbox Lube System: 10 micron nominal filter, Oil to air heat exchanger, 5 gallon reservoir, pressure and temperature protection, pressure gauge, temperature guage, oil level guage, clogged filter indicator. Pulse Generator: Zero speed, bi-directional, single ended. Output: 2 phase quadrature square wave, 240 pulses per revolution, 0-20 kilohertz, 0-5000 RPM, -20 to 180 Deg. F ambient. DC Drive System: Embedded controller, three phase four-quadrant power converter which operates at 47 to 63 Hz. Controls: speed, acceleration, direction, and torque. Protection include: motor over current, stall detection, power loss, phase loss, over/under voltage, motor overspeed, motor over acceleration, field loss, motor thermal protection. Speed regulation: within 0.1% of base speed from no load to rated continuous load (after a 30 minute warm up). Drive Isolation Transformer: UL listed, CSA certified, 118 KVA, heavy duty ventilated NEMA 1 enclosure, free-standing, dry-type (may be floor or wall mounted). Voltage tap: 5% FCAN & FCBN. 220 Deg. C insulation. 4-6% impedance. Meets UL and CSA short circuit withstand capacity. System Circuit Breaker: Three-pole, 600 VAC, UL rated enclosure. Thermal trip, magnetic trip and external shunt trip (Emergency Stop). DC Load Bank: 30 VDC, 1000 Amp (30kw). Integral control/metering panel. Cold to hot resistance: 1% Max. Resistors calibrated to +/2%. Cooling air loss protection. Integral Metering: DC Volts, Amps @0.5% of full scale. DC Starter Power Supply. 0-28 VDC, 0-1400 Amps (adjustable). Free standing NEMA 1 enclosure. AC circuit breaker, fused semiconductor protection, overload protection, 150% overload capacity (1minute). Regulation: +/-1% (current and voltage). Output ripple: 1% RMS (at rated load). Integral Meters: DC volts: +/-2% of full scale; DC amps: +/-2% of full scale.Locked Rotor Torque Components: Easy snap-in change from no-load speed to locked rotor test. Torque transducer: 0-50lbs. ft. (0-600 lbs. Inch), 2% of full scale (including meter). Speed metering: 0-9, 999 RPM, +/-2 RPM. Dynamic Torque Components: Hollow Reaction Torque Sensor (no moving parts, no bearings to wear out), 0-500 lbs.in, 2% of full scale (including meter). Analog feedback to DC Drive for Torque Setpoint testing. Testing can be accomplished two waysL set torque setpoint and adjust DC starter voltage, or set DC starter voltage and adjust torque control. Drive Controller and Metering: Microprocessor- based allowing control and/or display of ramp rate, overspeed protective setpoint, speed setpoint, actual speed display (resolution 1 RPM), fault display (drive fault, E-stop), torque setpoint and actual torque display. Aux Frequency: 0-2Khz, 0.1% of reading. Aux AC Volts: 0-200 V, .0.2% of reading. Demag Volts: 0-200 V, 0.2% of reading (Demag 0-40 V Max). Field current: 0-20 A, 0.3% of reading. Field Volts: 0-199.9 V, 0.05% of reading, Aux DC Volts: 0-199.9 V, 0.05% of reading. Temperature: 0-1562 Deg. F, +/-2.7 Deg. F. Portable Cooling: 3 HP motor, 0-16 inches of water pressure guage, butterfly valve. Blower: power cord, 4 foot by 4 inch dia. flexible hose; Generator Mounting: Mounting adapter to interface generator test stand with DC generator; Adapter: Bell Helicopter Textron Inc. P/N 214-175-150-105. As part of this procurement NAWCAD also intends to procure installation, power checks, start-up services, calibration verifications, training, and technical support for the generator test stand to be provided in country Taiwan. Additionally, the NAWCAD intends to procure spare parts for the generator test stand. Request copies in writing or by facsimile (908) 323-2165. (0277)

Loren Data Corp. http://www.ld.com (SYN# 0232 19961004\49-0001.SOL)


49 - Maintenance Repair Shop Equipment Index Page