COMMERCE BUSINESS DAILY ISSUE OF OCTOBER 21,1996 PSA#1704Defense Supply Center Columbus PO Box 16595 DSCC-PBAB Columbus, OH
43216-6595 59 -- RELAY, ELECTROMAGNETIC SOL SP0930-96-T-9006 DUE 102996 POC
Contact: for copy of solicitation FAX 614-692-2262 or mail request to
Defense Supply Center Columbus, PO Box 1659 5, DSCC-PBAB, Columbus, OH
43216-6595. contact contrac ting officer for info. please use entire
solicitations number when ordering documents. failure to do so may
result in non receipt or delay in receipt. F PR-NO: YPE96012000163 NSN
5945-00-679-1846, CAGE 04361 Part No MEP17 CAGE 04361 Part No
MEP17-28VDC CAGE 18876 Part No 9166041 CAGE 49956 Part No 2711385P1
CAGE 71313 Part No 9166041 CAGE 82415 Part No 6297-11 nonpile-up main
contact arrangement: 1 pole, double throw, one position momentary. Main
contact maximum voltage rating in volts: 115.0 AC main contact load
current rating at maximum rated voltage: 10.0 amperes AC resistive
load. Operating voltage rating and type at specified temp: 28.0 volts
DC 25 deg Celsius single winding 46 -EA Del to Mechanicsburg PA
17055-0789 Del by 15 Feb 96. Full and open competition: complete,
unrestricted data package available. Special provisions for first
article requirements test reports and samples/evaluations and approval.
Where to send samples and test report dscccmbg first article samples
for government evaluation will, upon completion of evaluation. be
returned to the contractot as production standards but shall not be
subm itted for acceptance as part of the order quantity. First article
samplesare to be retained by the contrac tor and disposed of as
follows: 1) sample will be retained as production standards but shall
not be submitted for acceptance as part of the order qty. Conditions
for waiver of first article testing: the government reserves the right
to waive the requireme Nt for first article testing for those offerors
of a product which A) has been previously accepted by the Gov't and has
not been found to be UNSATISFACTORY.B) has previously met the
preproduction testing requirement been accepted by the government and
has not been found to be unsatisfactory. C) has previously been
approved by the original equipment manufacturer (OEM), providing the
offeror can demonstrate approval and will certify HE has no evidence of
subsequent difficulty or disapproval by the CEM or any government
agency. Solicited various increments from: 20 to 79 i-5 first article
approval-contractor testing (X) (A) the contractor shall test 13 unit
(S) of lot/ ITEM____AS specified in this contract. (X) (B) estimated
test TIME_60 days. (X) (C)_60 days will be required for preproduction
test review(does not include mailing time). Engineering support/quality
assurance supplemental information 1) life test: Note 15 of Micom Dwg
# 9166041 shall include loading of N.O. and N.C. contacts with 10 amp
noninductive load at 115.0 volts A.C. with contacts making, but not
breaking the specified load. 2) vibration test: Note 17 of Micom Dwg #
9166041 shall be changed to read: ''vibrate material at 05 inch double
amplitude at 4 cycles per second for a period of 10.0 minutes delivery
schedule: 120 days standard size: 500 set-aside type: unrestricted
(sole source/single source) (no preference) all responsible sources may
submit offer which DESC shall consider.(0291) Loren Data Corp. http://www.ld.com (SYN# 0194 19961018\59-0002.SOL)