|
COMMERCE BUSINESS DAILY ISSUE OF DECEMBER 5,1996 PSA#1735Fluor Daniel Fernald, P.O. Box 538704, Cincinnati, Ohio 45253-8704 Z -- DEMOLITION SOL FSC 605 DUE 010697 POC Randy Ector, (513)
648-5170. Fluor Daniel Fernald (FDF), RFP No. FSC 605 is re-scheduled
for release on or about January 6, 1997 for the dismantling of Plant 9
and ancillary structures and Building Nos. 32A, 32B, 34, 64, 65, 78
and 81 (PLANT 9/THORIUM PROJECT) at the Department of Energy's
Environmental Management Project in Fernald, Hamilton County, Ohio.
NOTE: DUE TO UNCERTAINTIES REGARDING THE FEDERAL BUDGET, FUNDING IS
CURRENTLY NOT AVAILABLE FOR THIS PROJECT, HOWEVER, IT IS EXPECTED TO BE
AUTHORIZED FOR AN ANTICIPATED AWARD IN MID 1997. These buildings were
used to process, refine, and store uranium and thorium bearing products
during the production of metals for use in government defense programs.
The complete buildings, interior components and equipment, and
exterior equipment shall be dismantled, removed, segregated, cut,
containerized, and moved to specified project locations. Removal items
shall include the following: HVAC units, duct, process piping, service
piping, valves, gauges, instrumentation panels, electrical trays,
troughs, hangers, insulation, electrical control panels, process
equipment, doors, shelves, friable asbestos, asbestos transite siding,
sheet metal panels, gutters, exhaust vent, structural steel, cast
in-place concrete, steel decking, interior and exterior above ground
tanks, concrete equipment foundations, bridge cranes, and other
associated equipment. To be qualified to submit a proposal and receive
award for this work, a prospective offeror must: (A) provide a list
of ALL contracts meeting Criteria 1 through 6 whether successfully
performed or not. The list shall include (a) type of job (brief
description of work performed), (b) location, (c) point of contact and
telephone number of the project owner, (d) dollar value of work
performed by the prime contractor or lower tier subcontractor, as
applicable, and (e) identity of lower tier subcontracts, where
applicable. CRITERIA 1 -- Successful performance (quality, technical
and schedule) by the prime contractor of at least one (1) federal
government contract within the last five (5) years, in which the prime
contractor's contract amount was greater than $3 million and at least
45% of the work was performed directly by the prime contractor.
CRITERIA 2 -- Successful performance (quality, technical and schedule)
by the prime contractor of single or multiple contracts in remedial
de-construction/demolition work, in the last five (5) years, on
projects governed by OSHA/CERCLA or OSHA/RCRA in which the aggregate
prime contractor's contract value was greater than $5 million and at
least 45% of the work was performed directly by the prime contractor.
CRITERIA 3 -- Successful performance (quality, technical and schedule)
by the prime contractor or the named lower tier subcontractor of
asbestos abatement over the past five (5) years with an aggregate value
greater than $5 million. At least one (1) abatement project must have
been performed in exposed height conditions greater than 30 feet.
(Identify on list submitted.) This work must have been performed
directly by the prime contractor or the named subcontractor. CRITERIA
4 -- Successful performance (technical expertise and safe competent
execution) by the prime contractor or the named lower tier
subcontractor of rigging design and rigging for at least two (2)
engineered lifts of 10 tons or greater during the last five (5) years.
The rigging design and execution must be by the same firm. CRITERIA 5
-- Successful dismantlement (quality and schedule) by the prime
contractor or the named lower tier subcontractor of at least two (2)
structures greater than 30 feet in height in the past five (5) years
using mechanical shearing techniques. This work must have been
performed directly by the prime contractor or the named subcontractor.
CRITERIA 6 -- Successful performance (quality and schedule) by the
prime contractor on at least two (2) projects with an aggregate
contract value greater than $5 million where greater than 50% of the
work was directly performed wearing anti-contamination clothing and 50%
of the work was performed wearing respirators because of chemical and
radiological hazards. At least 25% of the experience shall be
radiological. (B) Provide documentation or statement for Criteria 7 and
8. CRITERIA 7 -- The prime contractor and the lower tier subcontractors
must be able to demonstrate to the satisfaction of FDF that it has a
record of safe construction performance as demonstrated by a current
workers compensation insurance experience modification rate (EMR) of
less than or equal to 1.05 or the trend for the past three (3) years
in downward and none of the past three (3) years has an EMR greater
than 1.25. CRITERIA 8 -- The prime contractor must be able and willing
to perform at least 45% of the work with their own forces. Prime
contractor may include wholly owned subsidiaries if the work was
performed or is to be performed as one integral project team. If the
prime subcontractor is a joint venture, the prime contractor criteria
may be met by one or a combination of the venturers. Estimated cost
$5,000,000 to $10,000,000; Bid Guarantee required; non-refundable
charge for solicitation documents to be determined. Interested firms
should send a LETTER OF QUALIFICATION referencing RFP No. FSC 605 and
including shipping address, contact, and telephone and fax numbers to
the attention of Randy Ector at FDF, P.O. Box 538704, Mail Stop 44,
Cincinnati, Ohio 45253-8704 no later than December 11, 1996. Checks
will not be accepted at this time. Qualified firms will be notified
approximately December 20, 1996 and requested to submit a check for the
solicitation documents at that time. The exact proposal due date will
be established by the RFP. All pre-qualified sources may submit a
proposal which will be considered. Any firm interested as a lower tier
subcontractor or supplier may obtain a copy of the solicitation by
sending a check to the above address, however, proposals will only be
accepted by FDF from pre-qualified ``PRIME'' offerors. (0338) Loren Data Corp. http://www.ld.com (SYN# 0115 19961205\Z-0012.SOL)
Z - Maintenance, Repair or Alteration of Real Property Index Page
|
|