COMMERCE BUSINESS DAILY ISSUE OF DECEMBER 12,1996 PSA#1740Navy Public Works Center Code 846 2730 McKean St Ste 1 San Diego CA
92136-5294 W -- RENTAL OF A.P.E. GROUT HANDLING EQUIPMENT SOL N63387-97-Q-M040
DUE 122795 POC Charles McNeill, Contracting Officer, (619)556-7631,
Jessie Bermudez, Purchasing Branch Supervisor, (619)556-7244, FAX:
(619)556-7806. Navy Public Works Center San Diego intends to negotiate
on a sole source basis with Masters Builders Inc., 23700 Chagrin
Blvd., Cleveland, Ohio 44122. 1 LOT Provide all labor, materials,
supplies, training, equipment, transportation and supervision required
to rent an air powered A.P.E. grout handling unit (Complete with 200
feet of dual hose grout umbilical and grout final mixing unit). 4 EACH
Jacket, fiber reinforced polymer 3/16 inch for encapsulation of 21
inch outside diameter steel pier vertical members. Length: 7.59 feet.
2 EACH Jacket, fiber reinforced polymer 3/16 inch for encapsulation of
21 inch outside diameter steel pier vertical members. Length: 8.59
feet. 2 EACH Jacket, fiber reinforced polymer 3/16 inch for
encapsulation of 21 inch outside diameter steel pier vertical members.
Length: 9.42 feet. 2 EACH Jacket, fiber reinforced polymer 3/16 inch
for encapsulation of 21 inch outside diameter steel pier vertical
members. Length: 10.75 feet. 2 EACH Jacket, fiber reinforced polymer
3/16 inchfor encapsulation of 21 inch outside diameter steel pier
vertical members. Length: 9.25 feet. 2 EACH Jacket, fiber reinforced
polymer 3/16 inch for encapsulation of 21 inch outside diameter steel
pier vertical members. Length: 10.25 feet. 2 EACH Jacket, fiber
reinforced polymer 3/16 inch for encapsulation of 21 inch outside
diameter steel pier vertical members. Length: 11.25 feet. 2 EACH
Jacket, fiber reinforced polymer 3/16 inch for encapsulation of 21 inch
outside diameter steel pier vertical members. Length: 11.67 feet. 2
EACH Jacket, fiber reinforced polymer 3/16 inch for encapsulation of
12.75 inch outside diameter steel pier horizontal members. Length:
12.11 feet. 1 EACH Jacket, fiber reinforced polymer 3/16 inch for
encapsulation of 12.75 inch outside diameter steel pier horizontal
members. Length: 12.53 feet. 1 EACH Jacket, fiber reinforced polymer
3/16 inch for encapsulation of 12.75 inch outside diameter steel pier
horizontal members. Length: 12.86 feet. 1 EACH Jacket, fiber reinforced
polymer 3/16inch for encapsulation of 12.75 inch outside diameter steel
pier horizontal members. Length: 13.45 feet. 1 EACH Jacket, fiber
reinforced polymer 3/16 inch for encapsulation of 12.75 inch outside
diameter steel pier horizontal members. Length: 13.99 feet. 1 EACH
Jacket, fiber reinforced polymer 3/16 inch for encapsulation of 12.75
inch outside diameter steel pier horizontal members. Length: 14.24
feet. 2 EACH Jacket, fiber reinforced polymer 3/16 inch for
encapsulation of 12.75 inch outside diameter steel pier horizontal
members. Length: 14.49 feet. 2 EACH Jacket, fiber reinforced polymer
3/16 inch for encapsulation of 12.75 inch outside diameter steel pier
diagonal members. Length: 13.36 feet. 1 EACH Jacket, fiber reinforced
polymer 3/16 inch for encapsulation of 12.75 inch outside diameter
steel pier diagonal members. Length: 14.16 feet. 1 EACH Jacket, fiber
reinforced polymer 3/16 inch for encapsulation of 12.75 inch outside
diameter steel pier diagonal members. Length: 14.84 feet. 1 EACH
Jacket, fiber reinforced polymer 3/16 inch for encapsulation of 12.75
inch outside diameter steel pier diagonal members. Length: 15.99 feet.
1 EACH Jacket, fiber reinforced polymer 3/16 inch for encapsulation of
12.75 inch outside diameter steel pier diagonal members. Length: 15.67
feet. 1 EACH Jacket, fiber reinforced polymer 3/16 inch for
encapsulation of 12.75 inch outside diameter steel pier diagonal
members. Length: 16.35 feet. 1 EACH Jacket, fiber reinforced polymer
3/16 inch for encapsulation of 12.75 inch outside diameter steel pier
diagonal members. Length: 17.07 feet. 6 GALLONS Adhesive, hydrocote
3061. 7 GALLONS Fillet, hydrocote 1063-SZ. 18 EACH Gaskets, bottom
seal. For horizontal fiber reinforced polymer jackets. 13.75 Inch. 21
EACH Gaskets, bottom seal. For vertical fiber reinforced polymer
jackets. 22 Inch. 32 UNITS Grout, A.P.E. part A&B liquid components.
For encapsulation of steel pier members. 10 Gallons per unit. 192 BAGS
Grout, A.P.E. Part C. 50 LB bag. 6 PAILS Lubricant, brutem grout
line-used to aid in pumping grout. This is a sole source requirement
because of existing patents. See Numbered Note(s): 22. (0345) Loren Data Corp. http://www.ld.com (SYN# 0084 19961212\W-0003.SOL)
W - Lease or Rental of Equipment Index Page
|
|