COMMERCE BUSINESS DAILY ISSUE OF DECEMBER 23,1996 PSA#1747Commercial Acquisition Department, Bldg. 11, Naval Undersea Warfare
Center Division, Newport, Code 59, Simonpietri Dr., Newport, RI
02841-1708 58 -- SOURCES SOUGHT FOR DUAL CHANNEL, 1 KVA PER CHANNEL POWER
AMPLIFIER POC Contact Carol Gorman, Contracting Officer at (401)
841-2442 X203. . Fax number (401) 841-4820. WEB: Naval Undersea Warfare
Center Division, Newport, http://www.npt.nuwc.navy.mil/contracts/.
E-MAIL: Carol R. Gorman, Contracting Officer,
GORMAN@CODE59.NPT.NUWC.NAVY.MIL. This is not an advertisement of a
solicitation at this time. Information only from potential sources as
requested below is being sought by the Naval Undersea Warfare Center,
Division Newport. We are looking for sources for a Dual Channel, 1KVA
per Channel, low distortion Power Amplifier for use on the Acoustic
Augmentation Support Program (see specification below). Please review
this information and provide factual supporting documentation,
including technical data sufficient to permit meaningful evaluation by
the requirer, and a description of your relevant corporate experience
(include applicable contract numbers and names of contract
administrators with their telephone number). Provide this information
to Carol Gorman, Commercial Acquisition Department, Building 11, Naval
Undersea Warfare Center Division Newport, Code 5913, Simonpietri
Drive, Newport, RI 02841-1708; or facsimile number 401-841-4820.
Responses before 17 January 1997 will be appreciated. Specification:
The followingdescribes t he electrical, physical, and environmental
requirements of a high power, very low distortion, Class B/AB, two
channel, solid state power amplifier. The amplifier will be used to
drive high power ceramic sonar transducers, with their associated
tuning and impedance matching transformers. Rated power into resistive
and reactive loads, low distortion, high reliability, and minimum
weight are key amplifier characteristics. Amplifier Requirements --
Number of Channels: Two (2). Operating Class: Class B/AB; ('s witch
mode' amplifiers are NOT acceptable). Output Power Per Channel: 1 KVA
min, single tone (sinusoidal), continuous duty, 20 Hz to 20 kHz. Load
Configuration: (GFE) Transformer plus resistive and reactive sonar
transducers. Load Impedance: (1) AC impedance magnitude, 8.0 Ohms min,
20 Hz to 20 kHz; (2) AC Impedance Phase Angle, (-)88 deg. to (+)88
deg.; (3) DC resistance, 0.1 Ohms min, (GFE transformer primary
winding). Damping Factor: 100 min, 20 Hz to 20 kHz. Voltage Gain &
Tolerance: 26 dB +/- 0 .5 dB, 8 Ohm load or higher; 20 Hz to 20 kHz.
Input Impedance: 10 K Ohms min, differential, 20 Hz to 20 kHz. Common
Mode Rejection: 40 dB min, 20 Hz to 20 kHz. Input Connectors: One (1)
isolated BNC connector per channel. Total Harmonic Distortion: 0.1%THD
max, lVA to lKVA output per channel, 20Hz to 20kHz. Self Protection:
Amplifier shutdown for output over-current or over-temperature. Prime
Power: 440V, +/- 10%, 3 Phase, 60 Hz, delta connected. Monitor
Features: Scaled replicas of output voltage an d current for each
channel. Weight: Minimum practical. Mounting Configuration: 19 inch
rack mountable. Depth behind front panel: 20.5 inches max, including
connectors, handles, etc. Depth in front of front panel: 2.5 inches
max, including handles, grills, etc. Height: Minimum practical.
Cooling: Internal forced air. Operational Ambient Temp.: 50 to 95
degrees F. The GFE transformer will be rack mounted with the power
amplifier, but not in the same enclosure (current equipment
configuration prohibits this). In light of this, size and weight
characteristics of the GFE transformer should not be a consideration.
(0354) Loren Data Corp. http://www.ld.com (SYN# 0285 19961223\58-0011.SOL)
58 - Communication, Detection and Coherent Radiation Equipment Index Page
|
|