COMMERCE BUSINESS DAILY ISSUE OF DECEMBER 24,1996 PSA#1748NIH, National Heart, Lung, and Blood Institute, DEA, COB, Procurement
Section, 6701 Rockledge Dr., RKL2 Rm 6150, Bethesda, MD 20892-7902. 65 -- HIGH VOLTAGE BIPOLAR PULSE GENERATOR SOL NHLBI-PS-PS-97-367 DUE
011097 POC Deborah Coulter, Purchasing Agent, (301) 435-0368 Fax
number (301) 480-3345. The National Heart, Lung, and Blood Institute
intends to purchase one (1) each High Voltage Bipolar Pulse Generator
with the following mandatory specifications: (1) able to operate
normally in a static magnetic field up to 50 Gauss; (2) able to
generate bipolar (positive-negative or negative-positive) electrical
pules into a 60ohm to 100ohm resistive or slightly capacitive load,
with peak voltages exceeding +- 4000 volts, and an overall pulse
duration of 1 microsecond; (3) able to generate the above described
pulses at a repetition rate of up to 1000Hz, with external trigger
capability; (4) the duration and voltage level is adjustable; (5)
provide monitoring ports for pulse shape and level monitoring; and (6)
two each (2) 5KV, Power Supply. The National Institute Of Health, must
be allowed to test the central components of the designs in the
magnetic environment area, and make necessary modifications. The
Company must be willing to spend the initial research effort to design
and construct a pulser in accordance with the government specific
requirements. The standard Industrial classification (SIC) Code 3825,
Size Standard 500 employees will be used for this requirement.
Interested vendors capable of furnishing the government with the
equipment specified in this synopsis should submit a Quotation, to the
below address. The quotation shall include the itemized price, the
period of delivery, prompt payment discount terms, taxpayer
identification number (TNN), Dun & Bradstreet Number (DUNs), and
descriptive literature of the equivalent product quoted identifying all
of the specifications. The quotation must reference "Request for
Quotation (RFQ) number #NHLBI-PS-SP-97-367. Quotations will be due
fifteen (15) calendar days from the publication date of this synopsis.
All responsible sources may submit a quotation, which if timely
received, shall be considered by the agency. Quotations must be
submitted in writing to the National Heart, Lung, and Blood, Institute,
Contracts Operation Branch, Procurement Section, Rockledge Building 2,
Room 6143, 6701 Rockledge Drive, Bethesda, MD 20817-7902, Attention:
Ms. Deborah Coulter. Fax quotations will only be accepted if dated and
signed by an authorized representative. (0355) Loren Data Corp. http://www.ld.com (SYN# 0264 19961224\65-0002.SOL)
65 - Medical, Dental and Veterinary Equipment and Supplies Index Page
|
|