COMMERCE BUSINESS DAILY ISSUE OF JANUARY 7,1997 PSA#1756Commander, Naval Air Warfare Center Weapons Division, Code 230000E, 521
N. 9th Street (Building 65), Point Mugu, CA 93042-5001 14 -- COUNTDOWN GENERATORS AND DISPLAY UNITS FOR MISSILE/TARGET LAUNCH
SEQUENCER SYSTEM SOL N68936-97-R-0075 DUE 022097 POC Willa Welch,
Contract Specialist, (805) 989-8136; Maria Miller, Contracting Officer,
(805) 989-0557. The Naval Air Warfare Center Weapons Division, Point
Mugu CA, intends to procure a Launch Countdown System that includes
Countdown Display Units and Countdown Generators (with spare boards).
The primary function of the Countdown System is to provide countdown
displays to all desired control spaces. The following specifications
apply: COUNTDOWN GENERATOR (Initial requirement 8 units; Option
quantity 2 units): Accuracy of 1/36,000 (1 sec for 10 hr countdown);
Code Output: Modified IRIG-B3 (Open DATUM Standard) (seconds, minutes,
hours, +/-, Hold, OP#); Carrier frequency 1,000 Hz; Code amplitude 0
to 5V p-p, adjustable; Modulation ratio 2:1 to 6:1, adjustable.
Countdown: Range -9:59:59 to +9:59:59 (hrs: min: sec). Countdown Manual
Preset: Countdown time and Operation Number are preset via thumb-wheel
switches. Stop/Enter/Run: Stop, Enter, Run Functions are enabled
through push-buttons on the front panel. Local/Remote: Local/Remote
switch shall Enable/Disable all of the functions on the front panel.
RS-232Interface: This Serial Interface shall provide the capability of
remotely presetting time and operation number and controlling Stop
(HOLD), Enter and Run. Display: +/- time direction, H for HOLD,
Operation Number (0000 to 9999), Range -9:59:59 to +9:59:59 (hrs: min:
sec). Power: 115 VAC, 60 Hz, 30 Watts max. Dimensions: (1"- 2") H x
19"W x (less than 18") D (19" Rack mountable). At least 0.4" LED
lights. Environment: Operating Temperature 0-50 Degrees C; Humidity
0-95% non-condensing. Other Requirements: No jumping in either up or
down counting mode; all external connectors shall be mounted on the
rear panel; all mating connectors shall be furnished by the Contractor.
COUNTDOWN DISPLAY UNIT, Type 1 (Initial requirement 30 units; Option
quantity 10 units): Code Input: Pseudo IRIG-B (Open DATUM Standard)
(seconds, minutes, hours, +/- Sign, hold, OP#) via BNC; Carrier
frequency 1 kHz; Mark to space ratio: 2:1 to 6:1. Amplitude (Mark):
From 0.25 volts to 10 volts peak-to-peak; Impedance: 600 ohms or 10,000
ohm bridging; Common mode rejection: Greater than 59db at 50Hz and 100
volts peak-to-peak. Input Level: 0.5Vp-p. Power Input: 115 Vac.
Dimensions: (Less than 2")H x 19"W x (less than 18")D (19" Rack
mountable); LED size: at least 0.56" high -- RED; LED Intensity:
Automatic level set. Display: +/- time direction, H for HOLD, Operation
Number (0000 to 9999), Range -9:59:59 to +9:59:59 (hrs: min: sec).
Environment: Operating Temperature 0-50 Degrees C; Humidity 0-95%
non-condensing. Other Requirements: No jumping in either up or down
counting mode; all external connectors shall be mounted on the rear
panel; all mating connectors shall be furnished by the contractor.
COUNTDOWN DISPLAY UNIT, Type 2 (Initial requirement, 6 units; Option
quantity, 2 Units): Code Input: Pseudo IRIG-B (Open DATUM
Standard)(seconds, minutes, hours, +/- Sign, hold, OP#) via BNC;
Carrier frequency 1 kHz; Mark to space ratio: 2:1 to 6:1; Amplitude
(Mark): From 0.25 volts to 10 volts peak-to-peak; Impedance: 600 ohms
or 10,000 ohm bridging; Common mode rejection: Greater than 59db at
50Hz and 100 volts peak-to-peak. Input Level: 0.5Vp-p. Power Input: 115
VAC (60Hz), 20W max. Dimensions: (Less than 4")H x 19"W x (less than
18")D (19" Rack mountable); LED size: at least 1.5" high -- RED; LED
Intensity: Automatic level set. Display: +/- time direction, H for
HOLD, Operation Number (0000 to 9999), Range -9:59:59 to +9:59:59 (hrs:
min: sec); Environment: Operating Temperature 0-50 Degrees C; Humidity
0-95% non-condensing. Other Requirements: No jumping in either up or
down counting mode; all external connectors shall be mounted on the
rear panel; all mating connectors shall be furnished by the Contractor.
COUNTDOWN DISPLAY UNIT, Type 3 (Initial requirement 18 units; Option
quantity 2 units): Code Input: Pseudo IRIG-B (Open DATUM
Standard)(seconds, minutes, hours, +/- Sign, Hold, OP#) via BNC;
Carrier frequency 1kHz; Mark to space ratio: 2:1 to 6:1; Amplitude
(Mark): From 0.25 volts to 10 volts peak-to-peak; Impedance: 600 ohms
or 10,000 ohm bridging; Common mode rejection: Greater than 59db at
50Hz and 100 volts peak-to-peak. Input Level: 0.5Vp-p. Power Input: 115
VAC (60 Hz), 30W max. Dimensions: (Less than 7")H x (less than 50")W x
(less than 12")D (Wall mount)(Max. dimensions 7"H x 50"W x 12" D); LED
size: at least 4" high -- RED; LED Intensity: Automatic level set.
Display: +/- time direction, H for HOLD, Operation Number (0000 to
9999), Range -9:59:59 to +9:59:59 (hrs: min: sec). Environment:
Operating Temperature 0-50 Degrees C; Humidity 0-95% non-condensing.
Other Requirements: No jumping in either up or down counting mode; all
external connectors shall be mounted on the rear panel; all mating
connectors shall be furnished by the Contractor. SPARE BOARDS for
Countdown Generators (Option item; 3 complete sets). Operations,
maintenance and troubleshooting manuals for Countdown Generators and
Countdown Display units shall be provided by the Contractor for all
initial units. Standards: Two Industry Standards are applicable. The
first Standard isthe Pseudo IRIG-B (Open DATUM Standard) used for the
Time Code Generators and the Countdown Displays. The second standard is
the EIA Standard RS232C used for serial transmission, required between
the Remote Sequencer Computer and the Time Code Generators. Delivery
of all units included in the initial requirement is required 140 days
after contract award. Requests for solicitation should be submitted in
writing to the above address no later than 15 days after publication
of this notice. All responsible offerors may submit proposals which
will be considered by the agency. (0003) Loren Data Corp. http://www.ld.com (SYN# 0070 19970107\14-0001.SOL)
14 - Guided Missiles Index Page
|
|