Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JANUARY 7,1997 PSA#1756

Commander, Naval Air Warfare Center Weapons Division, Code 230000E, 521 N. 9th Street (Building 65), Point Mugu, CA 93042-5001

14 -- COUNTDOWN GENERATORS AND DISPLAY UNITS FOR MISSILE/TARGET LAUNCH SEQUENCER SYSTEM SOL N68936-97-R-0075 DUE 022097 POC Willa Welch, Contract Specialist, (805) 989-8136; Maria Miller, Contracting Officer, (805) 989-0557. The Naval Air Warfare Center Weapons Division, Point Mugu CA, intends to procure a Launch Countdown System that includes Countdown Display Units and Countdown Generators (with spare boards). The primary function of the Countdown System is to provide countdown displays to all desired control spaces. The following specifications apply: COUNTDOWN GENERATOR (Initial requirement 8 units; Option quantity 2 units): Accuracy of 1/36,000 (1 sec for 10 hr countdown); Code Output: Modified IRIG-B3 (Open DATUM Standard) (seconds, minutes, hours, +/-, Hold, OP#); Carrier frequency 1,000 Hz; Code amplitude 0 to 5V p-p, adjustable; Modulation ratio 2:1 to 6:1, adjustable. Countdown: Range -9:59:59 to +9:59:59 (hrs: min: sec). Countdown Manual Preset: Countdown time and Operation Number are preset via thumb-wheel switches. Stop/Enter/Run: Stop, Enter, Run Functions are enabled through push-buttons on the front panel. Local/Remote: Local/Remote switch shall Enable/Disable all of the functions on the front panel. RS-232Interface: This Serial Interface shall provide the capability of remotely presetting time and operation number and controlling Stop (HOLD), Enter and Run. Display: +/- time direction, H for HOLD, Operation Number (0000 to 9999), Range -9:59:59 to +9:59:59 (hrs: min: sec). Power: 115 VAC, 60 Hz, 30 Watts max. Dimensions: (1"- 2") H x 19"W x (less than 18") D (19" Rack mountable). At least 0.4" LED lights. Environment: Operating Temperature 0-50 Degrees C; Humidity 0-95% non-condensing. Other Requirements: No jumping in either up or down counting mode; all external connectors shall be mounted on the rear panel; all mating connectors shall be furnished by the Contractor. COUNTDOWN DISPLAY UNIT, Type 1 (Initial requirement 30 units; Option quantity 10 units): Code Input: Pseudo IRIG-B (Open DATUM Standard) (seconds, minutes, hours, +/- Sign, hold, OP#) via BNC; Carrier frequency 1 kHz; Mark to space ratio: 2:1 to 6:1. Amplitude (Mark): From 0.25 volts to 10 volts peak-to-peak; Impedance: 600 ohms or 10,000 ohm bridging; Common mode rejection: Greater than 59db at 50Hz and 100 volts peak-to-peak. Input Level: 0.5Vp-p. Power Input: 115 Vac. Dimensions: (Less than 2")H x 19"W x (less than 18")D (19" Rack mountable); LED size: at least 0.56" high -- RED; LED Intensity: Automatic level set. Display: +/- time direction, H for HOLD, Operation Number (0000 to 9999), Range -9:59:59 to +9:59:59 (hrs: min: sec). Environment: Operating Temperature 0-50 Degrees C; Humidity 0-95% non-condensing. Other Requirements: No jumping in either up or down counting mode; all external connectors shall be mounted on the rear panel; all mating connectors shall be furnished by the contractor. COUNTDOWN DISPLAY UNIT, Type 2 (Initial requirement, 6 units; Option quantity, 2 Units): Code Input: Pseudo IRIG-B (Open DATUM Standard)(seconds, minutes, hours, +/- Sign, hold, OP#) via BNC; Carrier frequency 1 kHz; Mark to space ratio: 2:1 to 6:1; Amplitude (Mark): From 0.25 volts to 10 volts peak-to-peak; Impedance: 600 ohms or 10,000 ohm bridging; Common mode rejection: Greater than 59db at 50Hz and 100 volts peak-to-peak. Input Level: 0.5Vp-p. Power Input: 115 VAC (60Hz), 20W max. Dimensions: (Less than 4")H x 19"W x (less than 18")D (19" Rack mountable); LED size: at least 1.5" high -- RED; LED Intensity: Automatic level set. Display: +/- time direction, H for HOLD, Operation Number (0000 to 9999), Range -9:59:59 to +9:59:59 (hrs: min: sec); Environment: Operating Temperature 0-50 Degrees C; Humidity 0-95% non-condensing. Other Requirements: No jumping in either up or down counting mode; all external connectors shall be mounted on the rear panel; all mating connectors shall be furnished by the Contractor. COUNTDOWN DISPLAY UNIT, Type 3 (Initial requirement 18 units; Option quantity 2 units): Code Input: Pseudo IRIG-B (Open DATUM Standard)(seconds, minutes, hours, +/- Sign, Hold, OP#) via BNC; Carrier frequency 1kHz; Mark to space ratio: 2:1 to 6:1; Amplitude (Mark): From 0.25 volts to 10 volts peak-to-peak; Impedance: 600 ohms or 10,000 ohm bridging; Common mode rejection: Greater than 59db at 50Hz and 100 volts peak-to-peak. Input Level: 0.5Vp-p. Power Input: 115 VAC (60 Hz), 30W max. Dimensions: (Less than 7")H x (less than 50")W x (less than 12")D (Wall mount)(Max. dimensions 7"H x 50"W x 12" D); LED size: at least 4" high -- RED; LED Intensity: Automatic level set. Display: +/- time direction, H for HOLD, Operation Number (0000 to 9999), Range -9:59:59 to +9:59:59 (hrs: min: sec). Environment: Operating Temperature 0-50 Degrees C; Humidity 0-95% non-condensing. Other Requirements: No jumping in either up or down counting mode; all external connectors shall be mounted on the rear panel; all mating connectors shall be furnished by the Contractor. SPARE BOARDS for Countdown Generators (Option item; 3 complete sets). Operations, maintenance and troubleshooting manuals for Countdown Generators and Countdown Display units shall be provided by the Contractor for all initial units. Standards: Two Industry Standards are applicable. The first Standard isthe Pseudo IRIG-B (Open DATUM Standard) used for the Time Code Generators and the Countdown Displays. The second standard is the EIA Standard RS232C used for serial transmission, required between the Remote Sequencer Computer and the Time Code Generators. Delivery of all units included in the initial requirement is required 140 days after contract award. Requests for solicitation should be submitted in writing to the above address no later than 15 days after publication of this notice. All responsible offerors may submit proposals which will be considered by the agency. (0003)

Loren Data Corp. http://www.ld.com (SYN# 0070 19970107\14-0001.SOL)


14 - Guided Missiles Index Page