COMMERCE BUSINESS DAILY ISSUE OF JANUARY 22,1997 PSA#1766Navy Public Works Center Code 826 Bldg 343 2730 McKean St. Ste 1 San
Diego CA 92136-5294 Y -- PREENGINNERED METAL ROOF SYSTEM SOL N63387-97-Q-Q044 DUE 021497
POC Tony Zamora, Contracting Officer, (519)545-9411, FAX:(619)545-0243.
I LOT Pre-engineered metal roof system. Building size at top of block
-- 49 feet x 99 feet 4 inch from the 50 feet x 100 feet buidling size
on plans. Because of the two different size blocks making up the
exterior walls there will be a 4 inch step-in on each side of the
building. Including 1: Steel trusses with calcs. Include 4 feet
overhang on all sides. 2: Structual metal decking pre-primed. 3: R-19
rigid insulation to go over the decking. 4: Aluminim snap-in type or
crimped standing seam metal roofing with baked on Kynar finish for over
the insulation. 5: Decking to truss fastener. 6: Insulation to decking
fastener. 7: Standing seam roofing to decking fastener. Copies of this
solicitation will be provided in response to written or faxed requests.
Telephone requests will not be honored. (0017) Loren Data Corp. http://www.ld.com (SYN# 0109 19970122\Y-0012.SOL)