|
COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 19,1997 PSA#1785Phillips Laboratory/PKOV, Directorate of Contracting, Operational
Contracting Div, 2000 Wyoming Blvd SE, Kirtland AFB NM 87117-5606 99 -- CATHODIC PROTECTION AND GAS LINE LEAK DETECTION SURVEY SOL
F29650-97-QV137 DUE 031797 POC POC: Jim Sullenberger, Contract
Specialist, 505-846-2201; Contracting Officer, Kenneth G. West,
505-846-4190. Cathodic protection and gas line leak detection survey.
Sol: F29650-97-QV137. POC: Jim Sullenberger. The Operational
Contracting Division at Kirtland AFB, NM is seeking sources who can
provide a Cathodic Protection and Gas Line Leak Detection Survey. The
survey shall include performance testing and gas line leak survey. All
personnel conducting Cathodic Protection testing and measurements
shall be National Association of Corrosion Engineers (NACE) certified.
Proof of certification shall be provided prior to award of contract.
The period of performance is from date of award through 30 Sep 97. See
Note 26. An Ombudsman has been appointed to hear concerns from
offerors or potential offerors during the proposal development phase of
the acquisition. The purpose of the Ombudsman is not to diminish the
authority of the project director or contracting officer, but to
communicate contractor concerns, issues, disagreements, and
recommendations to the appropriate government personnel. Before
contacting the Ombudsman, potential offerors should first communicate
with the contracting officer. In those instances where offerors cannot
obtain resolution from the contracting officer, they are invited to
contact the PL Ombudsman, Col James D. Ledbetter, Phillips Laboratory
Vice Commander, at (505)846-4964, or 3550 Aberdeen Ave SE, Kirtland AFB
NM 87117-5776. When requested, the Ombudsman will maintain strict
confidentiality as to the source of the concern. The Ombudsman does not
participate in the evaluation of proposals or in the source selection
process. For contracting issues, contact Jim Sullenberger,
(505)846-2201. Firms responding to this announcement should indicate
whether they are or are not a Small Business, an 8(a) firm, a Socially
and Economically Disadvantaged firm, and/or a Woman-owned business.
The Government reserves the right to set aside this requirement for the
8(a) program, based on responses to the synopsis. Contractor must
indicate their size qualifications under SIC code 1799, Size standard
$7 million.Responses shall be received on or before 15 days after date
of this announcement. The Performance Work Statement for this
acquisition may be found a WWW.PLK.AF.MIL. Comments or questions should
be addressed to: Jim Sullenberger, Operational Contracting
Division/PKOV, 2000 Wyoming Blvd SE, Kirtland AFB, NM 87117-5777. Other
inquiries should be directed to Jim Sullenberger at (505) 846-2201.
(0045) Loren Data Corp. http://www.ld.com (SYN# 0280 19970219\99-0001.SOL)
99 - Miscellaneous Index Page
|
|