|
COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 20,1997 PSA#1786US Army Armament and Chemical Acquisition and Logistics Activity
(ACALA) Attn: AMSTA-AC-PCC (HRA), Rock Island, IL 61299-7630 43 -- ROTARY PUMP SOL DAAE20-97R0079 DUE 050897 POC Contract
Specialist: Cindy Ahrens (309) 782-4947, PCO: Robert C. Tedell (309)
782-3811 4320-01-288-6736, Part Number 5-45-5019. Rotary Pump consists
of Rotary vane pump with 1/4 inch BSP inlet and outlet ports.
Requirements are 29 ea Rotary Pump. For use on the M17 Decon Apparatus.
FOB is Origin. All or part of this action is an unfunded FY97
requirement. Proposed contract is a 100 percent small business
set-aside. ANSI/ISO/ASQC Q9002 or equivalent inspection criteria
required. First Article Test is required. A license agreement with
Engineered Air Systems & Karl H Hoie A/S requires that the items
procured be manufactured in the US, Canada, & U.S. Territories. U.S.
means the 50 states and the District of Columbia. Estimated issue date
of this solicitation is 032797. Any award resulting from this
solicitation will be a five-year indefinite quantity contract, with a
minimum quantity of 29 ea and a maximum quantity of 250 ea Rotary Pump
(PN 5-45-5019). It will also include a minimum of 0 with a maximum of
400 ea Photocell and Tee Assy (NSN: 4230-01-294-6871, PN: 5-45-5052)
and a minimum of 0 with a maximum of 350 ea Water Inlet Assy (NSN:
4230-01-293-3353, PN: 5-45-5180). The Photocell and Tee Assy consists
of tee, photocell, soldered; photocell assy; elbow, male 0.18 OD tube
by 0.12 NPT; nipple, hex, brass; screw, machine; and tube, air vent.
The Water Inlet Assy consists of a positive water displacement pump,
hose assy, and elbows. Pump must be purchased from the approved source.
Contractors are hereby notified of the following requirement: In order
to receive the solicitation/technical data package, all contractors
are required to execute a Nondisclosure Agreement binding contractors
to the terms and conditions of the agreement. Copies of the
Nondisclosure Agreement shall be requested from the following address:
Director, ACALA, ATTN: AMSTA-AC-PCH-A/Cindy Ahrens, Rock Island, IL
61299-7630. The Nondisclosure Agreement must be signed by an official
authorized to legally bind the company. Upon execution of the
Nondisclosure Agreement, return an original copy, certified mail to the
above address. Nondisclosure statements will be available prior to the
issuance of the solicitation and contractors are encouraged to request
and complete the above requirement as soon as possible. Failure to
properly address requests for solicitations in accordance with this CBD
notice will result in non-receipt of the solicitation package. Failure
to properly address bids/offers in accordance with solicitation
instructions may result in a late bid which cannot be considered.
Written, fax or electronic requests for solicitation packages are
accepted. No telephone requests will be honored. Requests for copies of
this solicitation should include your commercial and government entity
(CAGE) (if a CAGE code has been assigned to you) along with your name,
address, datafax number, and solicitation number. The fax number for
requests is (309)782-4728. Electronic requests may be accepted through
the Automated Acquisition Information System (AAIS). All ACALA
solicitations are available for viewing/downloading, in addition to
procurement history, via the AAIS. The AAIS can be accessed
electronically, 24 hours a day, using a modem set to dial
(309)782-7648. Terminal emulation should be VT100, no parity, 8 data
bits and 1 stop bit. Once connected, enter "aais" at the "LOGIN"
prompt. At the "PASSWORD" prompt depress the "ENTER" key. If electronic
means is not possible, procurement history will be provided
telephonically at (309)782-8094 on a limited basis. See Note(s): 1, 26.
(0049) Loren Data Corp. http://www.ld.com (SYN# 0232 19970220\43-0002.SOL)
43 - Pumps and Compressors Index Page
|
|