COMMERCE BUSINESS DAILY ISSUE OF FEBRUARY 28,1997 PSA#1792Naval Surface Warfare Center, Code 1163, 300 Highway 361, Crane, IN
47522-5001 41 -- DUAL MODE COOLING UNIT SOL N00164-97-R-0064 DUE 041597 POC Ms.
Roberta George, Code 1163WK, 812-854-1348, FAX 812-854-3465; Ms. S.R.
Burris, Contract Specialist WEB: click here to review synopsis,
http://www.crane.navy.mil/Webpages/Supply/homepages.htm. E-MAIL: click
here to request copy of solicittion, rhg972@smtp.nwscc.sea06.navy.mil.
<PRE>The Navy requires 1 each Electro Impulse Inc. dual mode
cooling unit, Model Number 51100, for installation on Coast Guard
Cutters to improve water flow and water quality. The requirement
includes four options: Options 1-3, 2 each and Option 4, 1 each.
Therefore, the total possible quantity for the procurement is 9 each.
The equipment definition is as follows: The cooling unit transfers the
heat from the load by means of a liquid to liquid heat exchanger in
the secondary (ships water) coolant line. The cooling unit shall
provide indicator lights for loss of power, coolant over temperature,
low coolant flow, low reservoir level and a meter for measuring water
resistivity. The cooling unit shall also have the built-in test
capability to test the indicators used for over temperature, low
reservoir level and low flow faults. The interface definition is as
follows: The cooling unit shall interface with the AN/SPS-40E Radar
through Unit 32. The Cooling Unit shall provide Unit 32 with 4.5GPM
minimum with a total 60 PSI drop through Units 28, 29 and 32. Utilizing
ships chilled water the cooling unit shall be capable of removing
18,050 BTU/HR. The dissolved oxygen content shall be 0.5 PPM by weight
maximum. The resistivity shall be 0.5 meg OHM/CM minimum. The coolant
pressure should not exceed 125 PSI. Delivery shall commence within 60
days after the effective date of the contract. F.O.B. destination
terms apply with inspection and acceptance at NAVSURFWARCENDIV Crane.
The acquisition of the Electro Impulse Inc. brand name cooling units is
essential to the Government's requirements. Therefore, this acquisition
will be issued on a sole-source basis in accordance with FAR 6.302-1(c)
for the Electro Impulse Inc. cooling units. All responsible sources may
submit an offer which will be considered by this Agency. When calling,
be prepared to state company name, address and solicitation number.
Requests for the solicitation may be made in writing to the above
address or by facsimile. SeeNumbered Note 22.<PRE> (0057) Loren Data Corp. http://www.ld.com (SYN# 0226 19970228\41-0002.SOL)