|
COMMERCE BUSINESS DAILY ISSUE OF MARCH 4,1997 PSA#1794Directorate Of Contracting, Oo-Alc 6050 Gum Lane/Bldg 1215, Hill Air
Force Base, Ut 84056-5825 13 -- CORD ASSY SOL F42630-97-Q-20904 DUE 040997 POC For copy,
PKX-2/Pamala Chaffee/(FAX)801-777-7522, For additional information
contact Genee Ringel/Likm/[801]775-2093 Item 0001 NSN
1377-01-216-5959ES P/N: 816739-93156, Acft ejection sys (life support)
ballistic device. Predom material explosive mix inside plastic wrap
inside steel tube with explosive charge of 0.0010 lbs length 25.40 in,
diameter 0.1875 in and is ball isticallly initiated. 10ea. Applicable
to: B-1b. Destn: Hill Air Force Base, Ut 84056-5825. Delivery: 31 Jul
97 10 ea Item 0002 NSN 1377-01-216-5964ES Cord Assy P/N: 816739-94028,
Acft ejection sys (life support) ballistic device. Predom material
explosive mix inside plastic wrap inside steel tube with explosive
charge of 0.0010 lbs length 19.60 in, diameter 0.1875 in and is
ballistically initiated. 10ea. Applicable to: B1b. Destn: Hill Air
Force Base, Ut 84056-5825. Delivery: 31 Jul 97 10 ea Item 0003 NSN
1377-01-216-6090ES Cord Assy P/N: 816739-93028, Acft ejection sys (life
support) Ballistic device. Predom material explosive mix inside plastic
wrap inside steel tube with explosive charge of 0.0010 lbs length 19.40
In, diameter 0.1875 in and is ballistically initiated. 10ea. Applicable
to: B1b. Destn: Hill Air Force Base, Ut 84056-5825. Delivery: 31 Jul 97
10 ea Item 0004 NSN 1377-01-217-3312ES Cord Assy P/N: 816739-93064,
Acft ejection sys (life support) ballistic device. Predom material
explosive mix inside plastic wrap inside steel tube with explosive
charge of 0.0010 lbs length 22.10 in, diameter 0.1875 in and is
ballistically initiated. 10ea. Applicable to: B1b. Destn: Hill Air
Force Base, Ut 84056-5825. Delivery: 31 Jul 97 10 ea Item 0005 NSN
1377-01-218-0336ES Cord Assy P/N: 816739-93204, Acft ejection sys (life
support) vallistic device. Predom material explosive mix inside plastic
wrap inside steel tube with explosive charge of 0.0007 lbs length 10.10
in, diameter 0.1875 i and is ballistically initiated. 10ea. Applicable
to: B1b. Destn: Hill Air Force Base, Ut 84056-5825. Delivery: 31 Jul
97 10 ea Item 0006 NSN 1377-01-218-0347ES Cord Assy P/N: 816739-93086,
Acft ejection sys (life support) ballistic device. Predom material
explosive mix insideplastic wrap inside steel tube with explosive
charge of 0.0011 lbs length 23.60 in, diameter 0.1875 in and is
ballistically initiated. 10ea. Applicable to: B1b. Destn: Hill Air
Force Base, Ut 84056-5825. Delivery: 31 Jul 97 10 ea There are 43
additional items(s) in FSC(s) 1377 The approximate issue/response date
will be 20 Mar 97. The anticipated award date will be 09 Apr 97.
Written procedure will be used for this solicitation. To: Teledyne
Mccormick Selph, Hollister Ca 95024 0006. No telephone requests. Only
written or faxed requests received directly from the requestor are
acceptable. All responsible sources solicited may submit a bid,
proposal, or quotation which shall be considered. It is suggested that
small business firms or others interested in subcontracting
opportunities in connection with the described procurement make contact
with the firm(s) listed. Specifications, plans, or drawings relating to
the procurement described are incomplete or not available and cannot be
furnished by the Government. Request for copies of solicitations must
reference the entire solicitation number, including purchasing office
identification number. To expedite your request, limit the number of
individual solicitation numbers requested per letter to not more than
10. Don't request information on this requirement until after the issue
date. An Ombudsman has been appointed to hear concerns from offerors or
potential offerors during the proposal development phase of this
acquisition. The purpose of the Ombudsman is not to diminish the
authority of the program director or contracting officer, but to
communicate contractor, concerns, issues, disagreements, and
recommendations to the appropriate government personnel. When
requested, the Ombudsman will maintain strict confidentiality as to the
source of the concern. The Ombudsman does not participate in the
evaluation of proposals or in the source selection process. Interested
parties are invited to call Jack S. Jones if your concerns are not
satisfied by the contracting officer (801)777-6991. The Government
physically does not have in its possession sufficient, accurate, or
legible data to purchase this part from other than the current
source(s). See Note (s) 26. (0059) Loren Data Corp. http://www.ld.com (SYN# 0149 19970304\13-0006.SOL)
13 - Ammunition and Explosives Index Page
|
|