COMMERCE BUSINESS DAILY ISSUE OF MARCH 5,1997 PSA#1795VA MEDICAL CENTER, 2300 RAMSEY STREET, FAYETTEVILLE, NC 28301 J -- J INSPECT FIRE ALARM EQUIPMENT SOL RFP 565-16-97 DUE 031897 POC
Candi Wood, Contract Specialist, (910) 822-7943 The VA Medical Center,
Fayetteville, NC, is requesting proposals to conduct quarterly
preventive maintenance inspections (in Dec, Mar, Jun, Sep) on the fire
alarm equipment installed at the VAMC. The base period will be from
date of award through September 30, 1997, and will include only three
inspections. There will be four one-year options to extend which will
cover the period of October 1 through September 30 for each year and
will include four inspections each year. Award will be made for the
base period with four option years. The system is a FAST multiplexed,
redundant CCS-1 fire alarm system including, but not limited to, the
following components: 28 IRC-1 remote panels; 3 annunciator panels; 160
smoke detectors (approximate count); 31 duct detectors; 7 heat
detectors; 34 water flow switches; 4 tamper/PIV switches; 39 tamper/OSY
switches; 92 pull stations; 150 indicator devices (approximate count);
2 terminals; and 5 printers. The contractor is responsible for
ensuring inspections encompass the complete inventory of the system.
Prints/schematics are available from Engineering Service. The equipment
shall be inspected and function in conformance with manufacturer's
specifications, the latest published editions of NFPA-13A, NFPA-25,
NFPA-72, NFPA-99, NFPA-101, and OSHA regulations. PM services shall
include, but need not be limited to, inspection, cleaning and any
adjustments necessary to maintain the equipment in good operating
condition. Contractor shall furnish all tools, test equipment, and
cleaning materials required. PM services not performed during the time
specified may result in a contract cost deduction. The VAMC shall not
provide service manuals to the contractor. The contractor shall
provide to the Contracting Officer's Technical Representative at the
completion of each inspection a service report indicating work
performed, actual values obtained (as applicable), detailed description
of work performed, condition of the system, and repairs or parts
needed. Such documentation shall be consistent with NFPA-72, Chapter 7,
Figure 7-5.1, Inspection and Testing Form. The Contractor shall
immediately, but not later than 24 hours after discovery, notify the
Contracting Officer and COTR in writing of the existence or the
development of any defects in, or repairs required, to the scheduled
equipment which the contractor considers he is not responsible for
under the terms of the contract. The contractor shall furnish the CO
and COTR with a written estimate of the cost to make necessary repairs.
Inspections shall be scheduled in advance with the Engineering Service
(910) 822-7041. There will be no additional charge for time spent at
the site during or after normal hours of coverage. Any additional
charges claimed must be approved by the Contracting Officer or designee
before service is completed. All work shall be performed by service
personnel who meet the requirements of NFPA-72, chapter 7, section
7-1.2.2, 1993. If subcontractors are used, they must be approved by the
CO. The contractor shall furnish a certificate of insurance indicating
workman's compensation and general liability insurance. Coverage may
not be changed or canceled without 30 days advance written notice.
Payment will be made monthly in arrears upon receipt of proper invoice
in accordance with the payment clauses of this solicitation. Invoices
should be submitted to Chief, Fiscal Service (04), VA Medical Center,
2300 Ramsey Street, Fayetteville, NC 28301. This is a combined
synopsis/solicitation for commercial items prepared in accordance with
the format in Subpart 12.6, as supplemented with additional
information included in this notice. This announcement constitutes the
only solicitation; proposals are being requested and a written
solicitation will not be issued. The following provisions apply to this
acquisition: 52.212-1, Instructions to Offerors -- Commercial Items;
52.212-3, Offeror Representations and Certifications -Commercial Items
(MUST BE RETURNED WITH OFFER). The following clauses apply to this
acquisition: 52.212-4, ContractTerms and Conditions -- Commercial
Items; 52.212-5, Contract Terms and Conditions Required to Implement
Statutes or Executive Orders -- Commercial Items; 52.222-3, Convict
Labor; 52.233-3, Protest After Award; 52.222-26, Equal Opportunity;
52.222-35, Affirmative Action for Special Disabled and Vietnam Era
Veterans; 52.222-36, Affirmative Action for Handicapped Workers;
52.222-37, Employment Reports on Special Disabled Veterans and Veterans
of the Vietnam Era; 52.217-5, Evaluation of Options; 52.217-9, Option
to Extend the Term of the Contract; 852.203-70, Ethics in Government
Act; 852.210-75, Technical Industry Standards; 852.210-70,
Veteran-owned Small Business (MUST BE RETURNED WITH OFFER); 852.237-70,
Contractor Responsibilities; 852.270-1, Representatives of Contracting
Officers; 852.270-4, Commercial advertising. Quotes are due by 2:00
p.m. March 18, 1997, and may be faxed to Candi Wood at (910) 822-7900.
Questions may be directed to (910) 822-7943. SIC Code 7382 applies.
Size standard is $9 million. (0059) Loren Data Corp. http://www.ld.com (SYN# 0044 19970305\J-0003.SOL)