Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF MARCH 7,1997 PSA#1797

U. S. Army Engineer District, Savannah, P.O. Box 889, Savannah, Georgia 31402-0889

C -- INDEFINITE DELIVERY/INDEFINITE QUANTITY (IDIQ) CONTRACT FOR HAZARDOUS, TOXIC AND RADIOACTIVE WASTE (HTRW) ENGINEERING SERVICES WITHIN THE SOUTH ATLANTIC DIVISION SOL DACA21-97-R0028 POC John Rigby (Technical Questions) 912/652-5718, Diane Thomas (Contractual Questions) 912/652-5728 INDEFINITE DELIVERY INDEFINITE QUANTITY (IDIQ) CONTRACT FOR HAZARDOUS, TOXIC AND RADIOACTIVE WASTE (HTRW) ENGINEERING SERVICES WITHIN THE SOUTH ATLANTIC DIVISION POC FOR THIS ANNOUNCEMENT IS JOHN RIGBY AT 912/652-5718(Technical Questions) and Diane Thomas at 912/652-5728(Contracting Questions). 1. CONTRACT INFORMATION: The Savannah District, U.S. Army Corps of Engineers, requires the services of a qualified Architect-Engineer firm for an 8(a) Indefinite Delivery Indefinite Quantity (IDIQ) Contract under SIC code 8711 for Environmental Engineering Services to include but not be limited to environmental site assessments, investigations, feasibility studies and remedial designs. The Contract will be administered by the Savannah District. The contract will consist of a basic ordering period and two option periods, each period not to exceed one year for a total of three years maximum. The total of all task orders during each ordering period may not exceed $1,000,000. However, the Government may exercise acontract option before the expiration of the base contract period (or preceding option period) if the contract amount for the base period (or preceding option period) has been exhausted or nearly exhausted. Individual task orders may not exceed $1,000,000. The total amount of the contract over the three year ordering period may not exceed $3,000,000. This announcement is for A-E 8(a) firms only and limited to Contractors located in SBA Region IV: FL,GA, SC, NC, AL,TN, MS, and KY. **** 2. PROJECT INFORMATION: Firms must have expertise in producing studies, and engineering designs under RCRA, CERCLA, SARA, UST, and other State/Federal environmental regulations. Responding firms must be affiliated with a laboratory that is either currently validated by the US Army Corps of Engineers, Missouri River Division (MRD) or that is capable of gaining the MRD validation prior to contract award. In addition to the MRD validation, where work under the resultant contract requires additional laboratory certification by a State, Territorial, or local Government, the affiliated laboratory must have or be able to obtain a required certification before work commences. Firms must indicate under project information the type of CADD system they employ, and if their system is not Intergraph, describe how they translate drawings into Intergraph. **** 3. SELECTION CRITERIA: See Note 24 for general selection process. The selection criteria are listed below in descending order of importance. Criteria a-d are primary. Criteria e-f are secondary and will only be used as "tie-breakers" among technically equal firms. **** a. Specialized experience in performance of environmental studies and designs conducted under RCRA, CERCLA, SARA, UST programs and regulations as well as other State/Federal environmental laws. Additionally responding firms must have expertise in CADD, risk assessment, regulatory requirements, cost engineering, ordnance & explosive waste (OEW), unexploded ordnance (UXO) and chemical warfare material (CWM), and conducting and participating in public hearings. b. Past Performance on DoD and other contracts with respect to cost control, quality of work and compliance with performance schedules. c. Capacity to perform numerous simultaneous delivery orders and sufficient staffing and/or team to accomplish same. Disciplines include chemical, civil, cost, environmental and geotechnical/soils engineering, geology, hydrogeology, geochemistry, geophysics, radiochemistry, health physics, analytical chemistry and industrial hygiene. Personnel expertise shall include certified industrial hygienist, certified health physicist (CHP) for radiological projects, certified safety professional (CSP) for UST projects, regulatory specialist, risk assessment specialist, Junior engineers, draftsmen, chemical testing technicians, soil and rock drilling and sampling technicians, ground and aerial surveying technicians and project managers. The laboratory must be certified by the State in which the laboratory services are being performed, by all appropriate Federal agencies, and by the U.S Army Corps of Engineers Missouri River Division Laboratory. These disciplines MUST be shown in BLOCK 4 of SF 255. Please disregard the "to be utilized" statement at Block 4 of SF 255 and show the total strength of each discipline; **** d. Professional qualifications to include appropriate professional registrations, certifications and other state licensing as required for personnel in the disciplines listed in 3c above. Firms must have state licensing for all professionals, trade certifications and licenses as required for projects located in, but not restricted to NC, SC, TN, GA, AL, MS, FL, PR, and VI. The states of registration and certification of each team member must be included in each resume in Block 7 of SF 255. **** e. Extent of participation as SB, SDB, WOB, HBCU, or MI as prime contractor, subcontractor or joint venture partner. **** f. Volume of DoD contract awards in the last 12 months. **** **** 4. SUBMISSION REQUIREMENTS: Interested firms having capabilities to perform this work must submit one (1) copy of SF 255 (11/92 edition) for PRIME and one (1) copy of SF 254 (11/92 edition) for prime and all consultants, to the following address: U.S. ARMY ENGINEER DISTRICT, SAVANNAH, ATTN: CESAS-EN-EA, 100 WEST OGLETHORPE AVENUE, SAVANNAH, GA 31401-3640 not later than the close of business the ***** 30th day **** after the DATE of this announcement. If the 30th day is a Saturday, Sunday, or Federal holiday, the deadline is the close of business of the next business day. INCLUDE THE FIRM'S ACASS NUMBER in Block 3b of SF 255. For ACASS information, call 503/326-3459. No faxed submittals will be accepted. Cover letters and extraneous material (Brochures, etc.) are not desired and will not be considered. **** PHONE calls are discouraged unless absolutely necessary. **** PERSONAL visits for the purpose of discussing this announcement will not be scheduled. **** THIS IS NOT A REQUEST FOR A PROPOSAL. (0064)

Loren Data Corp. http://www.ld.com (SYN# 0025 19970307\C-0004.SOL)


C - Architect and Engineering Services - Construction Index Page