COMMERCE BUSINESS DAILY ISSUE OF MARCH 27,1997 PSA#1811Sa-Alc/Support Equipment Branch, 485 Quentin Roosevelt Rd. St 7, Kelly
Afb, texas 78241-6426 66 -- TEST SET, FLOW RATE SOL F41608-97-R-20383 DUE 051497 POC For
copy, Fax request to LDKS at (210)925-1073, For additional information
contact Brown, C./ldksh/[210]925-4741 Item 0001 NSN 6680-01-380-4797
P/N: 2912BUX1, PART OF THE A/M99T-2 CALIBRATION TRAILER USED FOR ENGINE
TEST CELL CALIBRATION & REPAIR, MANIFOLD CONSISTS OF 2 TURBINE FLOW
TRANSMITTERS, ONE RATED AT 10/261 GPM THE OTHER AT 0.5/20 GPM, A 10K
OHM TRANSMITTER TEMPERATURE AND A SOLENOID VALVE TO DIFFERENTIATE FLOW
TRANSMITTERS. 50 FT CABLE ASSY IS INCLUDED. 120.0 VOLTS NOMINAL & 60.0
HERTZ NOMINAL FREQUENCY RATING. LAP TOP COMPUTER W/MONITOR, COMPUTER
PROGRAM, INTERFACE/AMPLIFIER & TURBINE MANIFOLD. PREDOMINANT MATERIAL:
STEEL SIZE & DIMENSIONS: FLOW RANGE OF 0.5/250 GPM, TEMPERATURE RANGE
OF +40/140 DEGREES F., VISCOSITY RANGE 0.8/50 CENTISTROKES. DELIVERY:
29 AUG 97 1EA. Applicable to: Fuel Flow Calibration. Destn: FMS.
Delivery: 29 AUG 97 1 ea Government specifications and drawings are not
available. Bid sets are not available. The approximate issue/response
date will be 14 Apr 97. The anticipated award date will be 16 JUN 97.
Written procedure will be used for this solicitation. To: FlowDynamics
Inc, Scottsdale Az 85260 0000. No telephone requests. Only written or
faxed requests received directly from the requestor are acceptable.
All responsible sources solicited may submit a bid, proposal, or
quotation which shall be considered. The proposed contract action is
for supplies and services for which the Government intends to solicit
and negotiate with only one, or a limited number of sources under the
authority of FAR 6.302. Interested persons may identify their interest
and capability to respond to the requirement or submit proposals. This
notice of intent is not a request for competitive proposals. However,
all proposals received within forty five-days (thirty days if award is
issued under an existing basic ordering agreement) after date of
publication of this synopsis will be considered by the Government. A
Determination by the Government not to compete this proposed contract
based upon responses to this notice is solely within the discretion of
the Government. Information received will normally be considered
solely for the purpose of determining whether to conduct a competitive
procurement. See Note (s) 22. (0084) Loren Data Corp. http://www.ld.com (SYN# 0265 19970327\66-0005.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|