COMMERCE BUSINESS DAILY ISSUE OF MARCH 31,1997 PSA#1813Supply Department Indian Head Division, Naval Surface Warfare Center,
101 Strauss Ave, Indian Head, MD 20640-5035 60 -- FIBER OPTIC CABLE SOL N0017497-R-0031 DUE 042897 POC Kay V
Proctor (301) 743-6680 This is a COMBINED SYNOPSIS/SOLICITATION for
commercial items prepared in accordance with the format in FAR Subpart
12.6, as supplemented with additional information included in this
notice. This announcement constitutes the only solicitation;proposals
are being requested and a written solicitation will not be issued. This
SOLICITATION NUMBER N00174-97-R-0031 is issued as a request for
proposal (RFP). The solicitation document and incorporated provisions
and clauses are those in effect through FEDERAL ACQUISITION CIRCULAR
#33. This solicitation is unrestricted. SIC is 3357 Description of
Requirements: Item Characteristics 1. Aerial Fiber Cable (12 Fibers)
Quantity : 52,000 ft Cable Characteristics The cable must be usable in
aerial and direct bury applications. It must be moisture and UV
resistant. . The cable must be all dielectric with the exception of the
integrated messenger. The cable must be self-supporting figure 8 cable,
with an integrated messenger of at least 1/4" diameter. Buffertubes
must be 2.4 mm in diameter and contain 6 fibers each. The operating
temperature range for the cable must be -40'C to +70'C or better. .
Cable sheath should be marked every foot with sequential length
markings in feet. . 6 of the fibers must be multimode and 6 of the
fibers must be single mode. Multimode Fiber Characteristics The
multimode fibers must have a core of 62.5 +/- 3.0 microns and a
cladding of 125 +/- 2.0 microns. The multimode fibers must also have a
core non-circularity of < 6.0% and a cladding non-circularity of
< 2.0%. The numerical aperture of the multimode fiber must be 0.275
+/- 0.015. Minimum bandwidth for multimode fiber is >= 160 MHz.km
@ 850nm and >=500 MHz.km @ 1300nm. Maximum attenuation for multimode
fiber is 3.5 dB/km @ 850nm and 1.0 dB/km @ 1300nm. Singlemode Fiber
Characteristics The singlemode fibers must have a core of 8.3 microns
and a cladding of 125 +/- 1.0 microns. The singlemode fibers must have
a cladding non-circularity of < 2.0%. The numerical aperture of the
singlemode fiber must be 0.13. The core-clad offset must be <= 1.0
micron. Maximum attenuation for singlemode fiber is 0.5 dB/km @ 131Onm
and 0.4 dB/km @ 1550nm. 2. Aerial Fiber Cable (24 Fibers) Quantity :
20,000 ft Cable Characteristics The cable must be usable in aerial and
direct bury applications. It must be moisture and UV resistant. The
cable must be all dielectric with the exception of the integrated
messenger. The cable must be self-supporting figure 8 cable, with an
integrated messenger of at least 1/4" diameter. . Buffer tubes must be
2.4 mm in diameter and contain 6 fibers each. The operating
temperature range for the cable must be -40'C to +70'C or better. Cable
sheath should be marked every foot with sequential length markings in
feet. . 12 of the fibers must be multimode and 12 of the fibers must be
single mode. Multimode Fiber Characteristics The multimode fibers must
have a core of 62.5 +/- 3.0 microns and a cladding of 125 +/- 2.0
microns. The multimodefibers must also have a core non-circularity of
< 6.0% and a cladding noncircularity of < 2.0%. The numerical
aperture of the multimode fiber must be 0.275 +/- 0.015. Minimum
bandwidth for multimode fiber is >= 160 MHz.km @ 850nm and >=500
MHz.km @ 1300nm. Maximum attenuation for multimode fiber is 3.5 dB/km
@ 850nm and 1.0 dB/km @ 1300nm. Singlemode Fiber Characteristics The
singlemode fibers must have a core of 8.3 microns and a cladding of 125
+/- 1.0 microns. The singlemode fibers must have a cladding
non-circularity of < 2.0%. The numerical aperture of the singlemode
fiber must be 0.13. The core-clad offset must be <= 1.0 micron.
Maximum attenuation for singlemode fiber is 0.5 dB/km @ 131Onm and 0.4
dB/km @ 1550nm. 3. Aerial Fiber Cable (48 Fibers) Quantity : 20,000 ft
Cable Characteristics . The cable must be usable in aerial and direct
bury applications. It must be moisture and UV resistant. . The cable
must be all dielectric with the exception of the integrated messenger.
. The cable must be self-supporting figure 8 cable, with an integrated
messenger of at least 1/4" diameter. . Buffer tubes must be 2.4 mm in
diameter and contain 6 fibers each. . The operating temperature range
for the cable must be -40'C to +70'C or better. . Cable sheath should
be marked every foot with sequential length markings in feet. . 24 of
the fibers must be multimode and 24 of the fibers must be single mode.
Multimode Fiber Characteristics The multimode fibers must have a core
of 62.5 +/- 3.0 microns and a cladding of 125 +/- 2.0 microns. The
multimode fibers must also have a core non-circularity of < 6.0% and
a cladding noncircularity of < 2.0%. The numerical aperture of the
multimode fiber must be 0.275 +/- 0.015. Minimum bandwidth for
multimode fiber is >= 160 MHz.km @ 850nm and >=500 MHz.km @
1300nm. Maximum attenuation for multimode fiber is 3.5 dB/km @ 850nm
and 1.0 dB/km @ 1300nm. Singlemode Fiber Characteristics The singlemode
fibers must have a core of 8.3 micronsand a cladding of 125 +/- 1.0
microns. . The singlemode fibers must have a cladding non-circularity
of < 2.0%. The numerical aperture of the singlemode fiber must be 0.
13. The core-clad offset must be <@ 1.0 micron. Maximum attenuation
for singlemode fiber is 0. 5 dB/km @ 13 1 Onm and 0.4 dB/km @ 1550nm.
4. Aerial Fiber Cable (96 Fibers) Quantity : 20,000 ft Cable
Characteristics . The cable must be usable in aerial and direct bury
applications. It must be moisture and UV resistant. . The cable must be
all dielectric with the exception of the integrated messenger. . The
cable must be self-supporting figure 8 cable, with an integrated
messenger of at least 1/4" diameter. . Buffer tubes must be 3.0 mm in
diameter and contain 12 fibers each. . The operating temperature range
for the cable must be -40'C to +70'C or better. . Cable sheath should
be marked every foot with sequential length markings in feet. . 48 of
the fibers must be multimode and 48 of the fibers must be single mode.
Multimode Fiber Characteristics The multimode fibers must have a core
of 62.5 +/- 3.0 microns and a cladding of 125 +/- 2.0 microns. The
multimode fibers must also have a core non-circularity of < 6.0% and
a cladding noncircularity of < 2.0%. . The numerical aperture of the
multimode fiber must be 0.275 +/- 0.015. Minimum bandwidth for
multimode fiber is >= 160 MHz.km @ 850nm and >=500 MHz.km @
1300nm. Maximum attenuation for multimode fiber is 3.5 dB/km @ 850nm
and 1.0 dB/km @ 1300nm. Singlemode Fiber Characteristics . The
singlemode fibers must have a core of 8.3 microns and a cladding of 125
+/- 1.0 microns. . The singlemode fibers must have a cladding
non-circularity of < 2.0%. . The numerical aperture of the
singlemode fiber must be 0. 13. . The core-clad offset must be <=
1.0 micron. . Maximum attenuation for singlemode fiber is 0.5 dB/km @
13 1 Onm and 0.4 dB/km @ 1550nm. 5. Aerial Fiber Cable (144 Fibers)
Quantity : 20,000 ft Cable Characteristics . The cable must be usable
in aerial and direct bury applications. It must be moisture and UV
resistant. . The cable must be all dielectric with the exception of the
integrated messenger. . The cable must be self-supporting figure 8
cable, with an integrated messenger of at least 1/4" diameter. . Buffer
tubes must be 3.0 mm in diameter and contain 12 fibers each. . The
operating temperature range for the cable must be -40'C to +70'C or
better. . Cable sheath should be marked every foot with sequential
length markings in feet. . 72 of the fibers must be multimode and 72 of
the fibers must be single mode. Multimode Fiber Characteristics The
multimode fibers must have a core of 62.5 +/- 3.0 microns and a
cladding of 125 +/- 2.0 microns. The multimode fibers must also have a
core non-circularity of < 6.0% and a cladding noncircularity of
< 2.0%. The numerical aperture of the multimode fiber must be 0.275
+/- 0.015. . Minimum bandwidth for multimode fiber is >= 160 MHz.km
@ 850nm and >=500 MHz.km @ 1300nm. Maximum attenuation for multimode
fiber is 3.5 dB/km @ 850nm and 1.0 dB/km @ 1300nm. Singlemode Fiber
Characteristics The singlemode fibers must have a core of 8.3 microns
and a cladding of 125 +/- 1.0 microns. The singlemode fibers must have
a cladding non-circularity of < 2.0%. The numerical aperture of the
singlemode fiber must be 0.13. . The core-clad offset must be <= 1.0
micron. . Maximum attenuation for singlemode fiber is 0.5 dB/km @
131Onm and 0.4 dB/km @ 1550nm. 6. Interconnect Center, 24 port, wall
mount Quantity : 75 ea. . It must contain a 24 port patch panel
separating the premises (termination) side from the interconnect (user)
side. . Each side must be locking using separate keys. . The premises
side must support standard splice trays including up to 4 . SIECOR
M67-060 trays. . Must have less than a 4" projection from the wall. .
The patch panel sleeves must be ceramic and capable of supporting both
multimode and singlemode ST connectors. . The premises side must have
cable management hardware to ensure the fibers maintain a proper bend
radius. 7. 10baseFL Transceivers Quantity : 75 ea. Transceiver must
meet or exceed all specifications for 10baseFL. Transceiver must have
I male AUI port and I pair of ST fiber optic ports. Transceiver must
have LED to indicate the following conditions : link, receive, jabber,
transmit, and collision. The contract will include option year I and
II with the following items for both years: items Quantity 1. Aerial
Fiber Cable (12 Fibers) 20,000 ft 2. Aerial Fiber Cable (24 Fibers)
10,000 ft 3. Aerial Fiber Cable (48 Fibers) 10,000 ft 4. Aerial Fiber
Cable (96 Fibers) 10,000 ft 5. Aerial Fiber Cable (144 Fibers) 10,000
ft 6. Interconnect Center, 24 port, wall Mount 50 each 7. 10baseFL
Transceivers 50 each FAR 52.212-1 Instructions to Offerors Commercial,
is incorporated by reference and applies to this acquisition FAR
52.212-2 Evaluation Commercial Items,is incorporated by reference and
applies to this acquisition. Addendum 52.212-2, Para. (a) The following
factors shall be used to evaluate offers: price only. Offerors shall
include a completed copy of the provision at FAR 52.212-3 Offeror
Representations and Certifications Commercial Items, with its proposal.
FAR 52.212-4 Contract Terms and Conditions Commercial Items is
incorporated by reference and applies to this acquisition and resulting
contract. The following terms and conditions are added as an addendum
to this clause: Type of contract: The resulting contract will be firm
fixed price. FAR 52.212-5 Contract Terms and Conditions Required To
Implement Statutes Or Executive Orders Commercial Items (Oct 1995) is
incorporated in this contract by reference, however for paragraphs (b)
and (c) only the following provisions apply to this acquisition: FAR
52.219-8 Utilization of small business concerns and small disadvantage
business concerns(15 U.S.C 637 (d)(2) and (3)): FAR 52.222-26 Equal
Opportunity (E>O> 11246). FAR 52.225-3 Buy American Act Supplies(
U.S.C. 10). FAR 52.225-21 Buy American Act North American Free Trade
Agreement Implementation Act Balance of Payments Program The proposal
are due 30 days after initial appearance of this synopsis in the CBD at
2:00 pm Naval Surface Warfare Center Indian Head Division, 101 strauss
ave Indian Head MD 20640-5035 Attn Kay v Proctor 1141w Offerors must
acquaint themselves with the new regulations concerning Commerical Item
acquisitions contained at FAR subpart 12 and must ensure that all
Representations and Certifications are executed and returned as called
in this synopsis/solicitation. For questions regarding this specific
acquisition contact Kay V Proctor by written fax (301) 743-6546.
(0086) Loren Data Corp. http://www.ld.com (SYN# 0287 19970331\60-0001.SOL)
60 - Fiber Optics Materials, Components, Assemblies and Accessories Index Page
|
|