Beach, CA 90740 J -- REFURBISHMENT OF SHIELDED ANECHOIC CHAMBER SOL N00244-97-Q-DR001
DUE 052897 POC Fax solicitation requests to Bid Branch (562) 626-7877;
Contract Specialist, Deborah Reid, (562) 626-7865 E-MAIL: Click here to
request an RFQ via e-mail, dkr6028@eagle.sbeach.navy.mil. Chamber built
by Emerson & Cuming, Inc. Refurbishment shall meet requirement for
antenna and EMI testing. Refurbishment shall be in compliance with all
local building and safety codes. Materials to be used for refurbishing
the chamber shall have self extinguishing burning characteristics,
i.e., the material will not burn by itself, and will not sustain
flaming once flame source is removed. Anechoic absorber material shall
cover ceiling, four walls and floor of the chamber. Absorber on the
floor shall be removable. As a min, walk-on absorber shall be provided
from door to and around the "Quiet Zone"and to opp. end of chamber
where typically a transmitting source might be positioned. If the
entire floor not covered with walk-on absorber can be rearranged as
needed. If the walk-on absorber is not at same level as shielded door
threshold, then a ramp shall be provided inside the chamber; the ramp
shall not degrade the chamber performance. Requirement includes
installation of new shielded door for enclosure. The new door shall
provide shielding effectiveness of a least 80 dB from 1 MHz to 10 GHz.
Complete SOW will be provided in RFQ. Place of performance Seal Beach,
CA. All responsible sources may submit an offer which shall be
considered. (0092) Loren Data Corp. http://www.ld.com (SYN# 0059 19970407\J-0001.SOL)