Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF APRIL 25,1997 PSA#1832

374th Contracting Squadron/LGCS, Unit 5228, APO AP 96328-5228

61 -- GENERATOR SOL F62562-97-T3041 DUE 050697 POC Point of Contact-Yoshiko Takeda, Contract Specialist, 011-81-425-52-3495(Comm Ph) or 011-81-425-53-7786(Fax), Contracting Officer -- Merry K. Sargent-Green, 011-81-425-52-3495 E-MAIL: 374th Contracting Squadron/LGCS, takeday@emh.yokota.af.mil. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. Therefore, this synopsis shall serve as a Request for Quotation, numbered F62562-97-T3041 which seeks quotations based on the informaiton contained in this synopsis. This synopsis and incorporated provisions/clauses are those in effect through Federal Acquisition Circular 90-42. It is the Government's intent to purchase Line Item 0001: 3 each of generator, diesel generator sysem. To replace generator. 240/416 volts, 3-phase, 50hz. Model 4S9, Standby ratings-85KW/106KVA. Radiator Model, DEC-3 control, 12 lead, P/N: PA-189616. To include: Weather Housing (installed), P/N: PA-254481. Industrial/Critical Silencer Mounting Hardware Kit (installed), P/N: PA-222858. Silencer-Industrial, 4" slip, side in/end out (installed), P/N: PA-253616. Tail Pipe and Rain Cap (installed), P/N: PA-273921. Block Heater, 110-120 Volts, 1500 Watts (installed), P/N: PA-275585. Battery Rack and Cables (installed), P/N: PA-273642. Battery Charger-Equalize Float, 12-Volts, P/N: PAC-292862. Flexible Fuel Lines, (2 with kit) (installed), P/N: PA-273628. Line Item 0002: 1 each of Diesel Generator System. To replace generator and ATS. P/N: PA-132814, 120/208 Volts, 60Hz 3-phase, 4-wire, Radiator Model: DEC-3 control, 12 lead (4M4019). To include: Block Heater, 2500 Watts, P/N: PA-279963, Flexible Fuel Lines, (installed), P/N: 274740. Flexible Exhaust Connector, P/N: PA-272720. Silencer Critical, 8"NPT Flange, Side-in/end-out, P/N: 274294. Adapter Bushing, 6"NPT-8"NPT, P/N: PA-274900. Battery-Charger-Equalize/Float. 24 Volts, P/N: PAC-292846. Battery Rack and Cables (installed), P/N: PA-274283. Series M340 ATS 4-Pole, P/N: K-568541-1200. MFR BY: Kohler Co. Delivery is required within 30 days ARO. FOB Point is Travis, CA. Responses to this notice will be considered for award to the responsible offeror submitting the lowest overall cost to the government. The following provision/clauses apply to this acquisition FAR 52.212-1, Instruction to Offerors-Commercial (Oct. 1995), 52.212-3, Offeror Respresentations and Certifications-Commercial Items (Mar 1996). 52.212-4 Contract Terms and Conditions-Commercial Items (Oct. 1995), 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders-Commercial Items (Aug. 1996). Submit with proposal, a completed copy of provisin 52.212-3. Facsimile offers will be accepted. POC for information regarding the solicitation is Ms. Takeda at 011-81-425-52-3495 (Comm Ph) or 011-81-425-53-7786(FAX). All responses from responsible sources will be fully considered. Award will be made without discussion. Only written requests submitted no later than 15 calender days after the publication date of this notice will be considered. (0113)

Loren Data Corp. http://www.ld.com (SYN# 0235 19970425\61-0006.SOL)


61 - Electric Wire and Power and Distribution Equipment Index Page