COMMERCE BUSINESS DAILY ISSUE OF APRIL 25,1997 PSA#1832374th Contracting Squadron/LGCS, Unit 5228, APO AP 96328-5228 61 -- GENERATOR SOL F62562-97-T3041 DUE 050697 POC Point of
Contact-Yoshiko Takeda, Contract Specialist, 011-81-425-52-3495(Comm
Ph) or 011-81-425-53-7786(Fax), Contracting Officer -- Merry K.
Sargent-Green, 011-81-425-52-3495 E-MAIL: 374th Contracting
Squadron/LGCS, takeday@emh.yokota.af.mil. This is a combined
synopsis/solicitation for commercial items prepared in accordance with
the format in Subpart 12.6, as supplemented with additional
information included in this notice. This announcement constitutes the
only solicitation; proposals are being requested and a written
solicitation will not be issued. Therefore, this synopsis shall serve
as a Request for Quotation, numbered F62562-97-T3041 which seeks
quotations based on the informaiton contained in this synopsis. This
synopsis and incorporated provisions/clauses are those in effect
through Federal Acquisition Circular 90-42. It is the Government's
intent to purchase Line Item 0001: 3 each of generator, diesel
generator sysem. To replace generator. 240/416 volts, 3-phase, 50hz.
Model 4S9, Standby ratings-85KW/106KVA. Radiator Model, DEC-3 control,
12 lead, P/N: PA-189616. To include: Weather Housing (installed), P/N:
PA-254481. Industrial/Critical Silencer Mounting Hardware Kit
(installed), P/N: PA-222858. Silencer-Industrial, 4" slip, side in/end
out (installed), P/N: PA-253616. Tail Pipe and Rain Cap (installed),
P/N: PA-273921. Block Heater, 110-120 Volts, 1500 Watts (installed),
P/N: PA-275585. Battery Rack and Cables (installed), P/N: PA-273642.
Battery Charger-Equalize Float, 12-Volts, P/N: PAC-292862. Flexible
Fuel Lines, (2 with kit) (installed), P/N: PA-273628. Line Item 0002:
1 each of Diesel Generator System. To replace generator and ATS. P/N:
PA-132814, 120/208 Volts, 60Hz 3-phase, 4-wire, Radiator Model: DEC-3
control, 12 lead (4M4019). To include: Block Heater, 2500 Watts, P/N:
PA-279963, Flexible Fuel Lines, (installed), P/N: 274740. Flexible
Exhaust Connector, P/N: PA-272720. Silencer Critical, 8"NPT Flange,
Side-in/end-out, P/N: 274294. Adapter Bushing, 6"NPT-8"NPT, P/N:
PA-274900. Battery-Charger-Equalize/Float. 24 Volts, P/N: PAC-292846.
Battery Rack and Cables (installed), P/N: PA-274283. Series M340 ATS
4-Pole, P/N: K-568541-1200. MFR BY: Kohler Co. Delivery is required
within 30 days ARO. FOB Point is Travis, CA. Responses to this notice
will be considered for award to the responsible offeror submitting the
lowest overall cost to the government. The following provision/clauses
apply to this acquisition FAR 52.212-1, Instruction to
Offerors-Commercial (Oct. 1995), 52.212-3, Offeror Respresentations and
Certifications-Commercial Items (Mar 1996). 52.212-4 Contract Terms and
Conditions-Commercial Items (Oct. 1995), 52.212-5, Contract Terms and
Conditions Required to Implement Statutes or Executive
Orders-Commercial Items (Aug. 1996). Submit with proposal, a completed
copy of provisin 52.212-3. Facsimile offers will be accepted. POC for
information regarding the solicitation is Ms. Takeda at
011-81-425-52-3495 (Comm Ph) or 011-81-425-53-7786(FAX). All responses
from responsible sources will be fully considered. Award will be made
without discussion. Only written requests submitted no later than 15
calender days after the publication date of this notice will be
considered. (0113) Loren Data Corp. http://www.ld.com (SYN# 0236 19970425\61-0007.SOL)