COMMERCE BUSINESS DAILY ISSUE OF MAY 1,1997 PSA#183645CONS, 1201 Minuteman St, MS 7200, Patrick AFB, FL 32925-3237 49 -- RECYCLING/RECLAMATION SYSTEM SOL F08650-97-TC-659 DUE 061797 POC
Lear Matus, Contract Specialist (407) 494-9512/Jimmy McDaniel,
Contracting Officer (407) 494-7227 The government has a requirement for
a metal can/oil filter crusher, Enviro Care Kruncher Corp model RS43590
or equal. This is a commercial buy. A. The crusher must meet the
following criteria and perform the following operations: 1) Fully
automatic operation after hopper is filled; 2) Computer controlled
operations and system management; 3) Hold approximately 400 uncrushed
oil filters in a hopper; 4) Must process cans up to 1 gallon in size,
i.e. empty paint cans, food cans, empty aerosol cans, and used oil
filters; 5) Have a 40-gallon capacity minimum holding tank for
collection of liquids; 6) Magnetic separator to remove fine metal
particles from liquid holding tank prior to liquids entering pump; 7)
Have a transfer pump from the liquid holding tank with a standard
2-inch threaded pipe connection with cut off valve; 8) Transfer pump
must pump wet or dry; 9) Outer casing/hood must be power operated for
ease of cleaning interior of machine; 10) Crusher must automatically
discharge metal brick once maximum density is obtained. B. Output
product and average size: 1) Must produce a high density block (not
puck) of metal approximately 3 x 3 x 7 inches; 2) Extremely dense metal
brick must have minimum of 98% liquid removed. C. Power requirements:
3 phase, 208 volts, 60 cycle. D. Electrical motor requirements: 1) 10
horse power minimum; 2) Multi-axis hydraulic compaction; 3) Hydraulic
oil cooler. E. Size requirements: Must not exceed 8 ft long x 5 ft wide
x 5 ft high. Maximum height when outer case open, 9 ft. This
acquisition is unrestricted. The applicable SIC code and size standard
are 3569/500 employees. Solicitation issue date of 19 May 97 and offer
due date of 17 Jun 97 are tentative. Requests for the solicitation must
be faxed to (407) 494-2983 or mailed to 45 CONS/LGCSAL, Attn: L Matus,
1201 Minuteman St M/S 7200, Patrick AFB FL 32925-3237. Phone calls
will not be accepted. All responsible sources may submit an offer which
will be considered by the 45th Space Wing. (0119) Loren Data Corp. http://www.ld.com (SYN# 0234 19970501\49-0003.SOL)
49 - Maintenance Repair Shop Equipment Index Page
|
|