COMMERCE BUSINESS DAILY ISSUE OF MAY 2,1997 PSA#1837NCCOSC RDTE Division, Code D214B, 53570 Silvergate Avenue, Bldg. A33,
San Diego, CA 92152-5113 43 -- COMPRESSORS & VACUUM PUMPS SOL N66001-97-Q-0181 DUE 051797 POC
Purchasing Agent, Ms. Angela King, Code D222, (619)553-5829.
Contracting Officer, Ms. Cindy Frison, (619)524-2354. This is a
requirement for the following items: (1) Oil-free vacuum pump system,
capable of pumping more than 180 cubic feet per minute of nitrogen, and
reaching a base pressure of at least 1.0 X 10 exp (-3) TORR. The pump
system must be fully intergradable with an applied materials P5000
SACVD system including automatic controls for turning the pump on and
off, and signaling an overtemperature condition. The footprint of the
system must not exceed 24 inches by 48 inches, (Qty. 1 each). (2).
Oil-free vacuum pump system, capable of pumping more than 55 cubic feet
per minute of nitrogen, and reaching a base pressure of at least 8.0 x
10 exp (-3) TORR. The pump system must be fully intergradable with an
applied materials P5000 SACVD system including automatic controls for
turning the pump on and off, and signaling an overtemperture
condition. The footprint of the system must not exceed 24 inches by 48
inches, (Qty. 1 each). Delivery: Advise as to the lead time. Delivery
to made FOB Destination to: NCCOSC RDT&E Div., 53605 Hull Street, San
Diego, CA 92152-5410. Quotations sent via the U.S. mail should be
mailed to: NCCSOC RDT&E Div., Code D222, Bldg. 33, Rm. 0601, Attn:
Angela King, 53560 Hull Street, San Diego, CA 92152-5001. All
quotations not sent through the U.S. mail can be faxed to
(619)553-5996. "No RFQ will be prepared or made available for
distribution. Award will be based on evaluation of responsive,
responsible quotations received in response to this CBD advertisement.
Competitive awards may be based on the evaluation criteria stipulated
in the Red, Yellow, Green (RYG) Contractor Evaluation System. The
evaluation criteria is available upon request. Questions may be
directed to Angela King at (619)553-5829. Facsimile quotations are
acceptable and must be received on or before the COB on the closing
date stated above. Facsimile quotations may be sent to (619)553-5996."
See numbered notes: 1. The applicable Standard Industrial Code (SIC)
and size standard is: 3561 -- 500 employees. (0119) Loren Data Corp. http://www.ld.com (SYN# 0231 19970502\43-0002.SOL)
43 - Pumps and Compressors Index Page
|
|