COMMERCE BUSINESS DAILY ISSUE OF MAY 5,1997 PSA#18387th Contracting Squadron, 381 Third Street, Dyess AFB, TX 79607-1581 Z -- CONSTRUCT METAL AWNING SOL F41652-97-Q0243 DUE 051697 POC SrA
Michael Holder 915-696-2360 or Mr Ron McGuire 915-696-2679 The
contractor shall furnish all plant, labor, materials, equipment and
performance of operations required to construct a metal awning at Dyess
AFB, TX. The contractor shall perform to the standards in this contract
and all current industry standards. The contract shall construct a
Southwestern Style roof at facility 11955. The canopy shall be 84 feet
by 16 feet and have at least 3 feet of rise. Metal screen shall be
constructed to hide framing from the second floor windows. The portion
of the screen visible from the from the interior shall be painted to
match interior paint; use off white (FSC 27778). The portion of the
metal screen visible from underneath the canopy shall be painted to
match the underside of the canopy; use off white (FSC 27778). The
height of the awning shall be sufficient to provide at least 8 feet of
clearance from the patio deck to the lowest part of the awning. The
canopy will be free standing and supported by columns placed in pairs
16 feet apart, with bays to be 12 feet apart (to match structural grid
already in place). The columns shall be 4 inch by 4 inch metal posts,
painted to match canopy (FSC 26044). Use 8 inch C purling rafters, 4
inch C purling attached to roof panels, U panel roofing with exposed
screws. Paint framework off white (FSC 27778) before attaching roofing
panels. Install 3 light fixtures, wiring in conduit. Existing awning
must be torn down and disposed of off base, at the contractor's
expense. The canopy must resist normal leakage and wind loads of 80
mph/Gust upto 100 mph. The canopy exterior metal shall be constructed
of at least 22 gauge metal paneling and fascia. The paneling and fascia
shall be colored either MBCI Charcoal Gray, (FSC 26044) with Dexstar
850 Finish or SSR Patrician Bronze (FSC 26044) with KXL Kynar Finish or
equivalent. The canopy must be lighted with light fixtures meeting the
following specifications: 12 inch X 12 inch 2 and 1/4" standard drop
in prismatic diffusers (equal or equivalent to RUUD model MCL0405-D),
50 watt metal halide direct mount. The contractor must provide shop
drawings to the Contracting Officer and received approval before
proceeding on the project. A pre-bid site visit is scheduled for 09 May
97. Bid opening will be on or about 16 May 97. This is a combined
synopsis/solicitation for commericial items prepared in accordance with
the format in FAR Subpart 12.6, as supplemented with additional
information included in this notice. This announcement constitutes the
only solicitation; proposals are being requested and a writen
solicitation will not be issued. (0120) Loren Data Corp. http://www.ld.com (SYN# 0118 19970505\Z-0005.SOL)