Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF MAY 16,1997 PSA#1847

Commander, Naval Air Warfare Center Weapons Division, Code 230000D, 1 Administration Circle, China Lake, CA 93555-6100

41 -- SELF-CONTAINED PACKAGED AIR-TO-AIR HEAT PUMP SOL N68936-97-Q-1836 DUE 062497 POC Phyllis Jenkins, Purchase Agent, 760-939-4277. The Naval Air Warfare Center, Weapons Division, China Lake, CA intends to procure Competitively a Self-Contained Packaged Air-to-Air Heat Pump. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation, quotations are being requested and a written solicitation will not be issued. The Solicitation number is N68936-97-Q-1836 and is issued as a Request For Quote (RFQ). This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 90-37. This is a small purchase, small business set-aside, the SIC Code is 3585, Size Standard is 750. Following are the specifications for each Item: Item Number 0001, 16 Each -- Self-Contained Packaged Air-to-Air Heat Pump (our Unit HP-2), designed for through the wall installation, provided with non-corrosive wall sleeve -- Maximum size 42-inches wide X 16-inches high. To fit existing openings. To include standard aluminum outdoor grille, front enclosure, external drain, operating and safety controls with a two-stage thermostat. Unit to be ready for installation and operation. To have standard cord connected to chassis. 208/230 volt, single phase, 60 hertz. Unit to have 5.0 K.W. heat strip (electrical heater size). Cooling and heating capacities as follows (rated in accordance with ARI Standard 310/380-93): Minimum cooling capacity -- 13,100 BTUH, minimum reverse cycle heating capacity -- 12,000 BTUH, minimum electric heating capacity -- 13,600. Energy efficiency Ratio -- 8.8/8.8 (EER), coefficient of performance at 47 degrees -- Fahrenheit. Outdoor ambient temperature -- 2.6/2.6 (COP); 6.9/7.4 cooling amps, 22.6/19.9 heating amps. 1,530/1,500 cooling watts, 5,210/4, 170 heating watts. Unit to be UL and CSA Certified. Unit to have a cleanable type air supply filter. Minimum circuit -- 28 AMPS, Maximum fuze size—30 AMPS. Site elevation is 2,250 feet. Manufacturer "Carrier" Model 52SQC514-3 or Equal. Item Number 0002 -- 12 Each, Self-contained packaged air-to-air heat pump (our unit HP-1), designed for through the wall installation provided with non-corrosive wall sleeve -- Maximum size 42-inches wide x 16-inches high to fit existing openings. To include standard aluminum outdoor grille, front enclosure, external drain, operating and safety controls with a two-stage thermostat. Unit to be ready for installation and operation. To have standard cord connected to chassis. 208/230 Volt, Single Phase, 60 Hertz. Unit to have a 3.0 K.W. heat strip (electrical heater size). Cooling and heating capacities as follows (rated in accordance with ARI Standards 310/380-93): Minimum cooling capacity -- 11,300 BTUH, minimum reverse cycle heating capacity -- 10,700 BTUH, minimum electric heating capacity -- 9,500 BTUH. Energy efficiency ratio -- 9.0/9.0 (EER), coefficient of performance at 47 degrees Fahrenheit outdoor ambient temperature -- 2.8/2.8 (COP); 5.9/6.3 cooling AMPS, 15.8/14.4 heating AMPS. 1,333/1,311 cooling WATTS, 3,601/3,000 heating WATTS. Unit to be UL and CSA Certified. Unit to have a cleanable type air supply filter. Minimum circuit -- 18.0 AMPS. Maximum fuze size -- 20 AMPS. Site elevation is 2,250 feet. Each unit to have installation, operating and parts manuals, and warranty information. Manufacturer "Carrier" Model 52SQD312-3 or Equal. All units must be the same Model number. All bids of Equals must have Manufacturer Literature and Specifications included. No End-of-Production units or Out-of-Production units will be accepted. Delivery is required on or before 16 June (PARTIAL DELIVERY REQUIRED) to NAWS China Lake, CA, FOB Destination. Provision 52.212-1, Instructions to Offerors -- Commercial, applies to this acquisition and there are no addendums to the provision. Offeror must include a completed copy of Provision 52.212-3, Offeror Representations and Certifications -- Commercial Items with his offer. Clause 52.212-4, Commercial Terms and Conditions -- Commercial Items applies to this acquisition and there are no addendums to this clause. Clause 52.212-5, Contract Terms and Conditions Required to Implement Statutes or Executive Orders -- Commerical Items, Clause 52.222-26, Equal Opportunity, Clause 52.222-35, Affirmative Action for Special Disabled and Vietnam ERA Vetrans, Clause 52.222-36, Affirmative Action for Handicapped Workers, 52.222-37, Employment Reports on Special Disabled Veterans and Veterans of the Vietnam ERA applies to this acquisition and there are no addendums to these clauses. All responsible sources which comply with the criteria above may submit a quotation which will be considered by the agency. Respondents shall submit their quotation on or before 24 Jun by 4:30pm Pacific time, to Phyllis Jenkins, NAWCWPNS, Code 230000D, China Lake, CA 93555-6100 or fax to 760-939-4290. This acquisition is being awarded under FAR Part 12 procedures. Award will be made on or about 30 June. (0134)

Loren Data Corp. http://www.ld.com (SYN# 0323 19970516\41-0002.SOL)


41 - Refrigeration, Air Condition and Air Circulating Equipment Index Page