Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF MAY 23,1997 PSA#1852

DHHS, PHS, CDC, NIOSH, ALOSH, 1095 Willowdale Rd., Morgantown, WV 26505-2888

66 -- LOGIC ANALYZER MAINFRAME FOR THE APPALACHIAN LABORATORY FOR OCCUPATIONAL SAFETY AND HEALTH,M MORGANTOWN, WV SOL 97-008 DUE 061697 POC Brenda Goodwin, 304/285-5882/Contracting Officer, Rex S. Wolfe, Jr., 304/285-5883 THIS IS A COMBINED SYNOPSIS/SOLICITATION FOR COMMERCIAL ITEMS PREPARED IN ACCORDANCE WITH THE FORMAT IN SUBPART 12.6, AS SUPPLEMENTED WITH ADDITIONAL INFORMATION INCLUDED IN THIS NOTICE. THIS ANNOUNCEMENT CONSTITUTES THE ONLY SOLICITATION; QUOTES ARE BEING REQUESTED AND A WRITTEN SOLICITATION WILL NOT BE ISSUED. This solicitation is issued as Request for Quotation No. 97-008. This procurement is being issued unrestricted. The Standard Industrial Classification is 3829 with a size standard of 500 employees. This solicitation document and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 90-46. Contract Line Item 001 -- 1 EACH -- Logic Analyzer Mainframe System similar to Tektronix Models TLA704; TLA7L1 andTLA7D1 with various options to provide high quality logic analysis capability to the ECTB lab. Equipment offered shall meet the following detailed specifications: (1) The unit shall have at least 34 channels with 128KB of memory; (2) The unit shall time stamp the data acquisition without any memory degradation; (3) The unit shall provide at least 16 independent trigger states with 4 independent if-then conditions per each 16 states. Each if-then construct shall be able to qualify on up to 8 events/actions; (4) The unit shall have at least 100 MHz state acquisition capability and 2 Ghz timing resolution on all channels available at all times; (5) The unit shall provide simultaneous state and timing analysis through the same probe; (6) The unit shall include a 2 channel 500 MHz oscilloscope with 2.0 Ghz/sec sampling on both channels. Each oscilloscope channel shall have at least 8 KB of memory; (7) The unit shall have at least 3- years repair and calibration services. The Government will evaluate based on F.O.B. Destination (Morgantown, West Virginia) and the requirements at FAR 52.214.21 "Descriptive Literature" apply. Information provided must demonstrate the unit's ability to meet the specification or your offer may be rejected. The following FAR provisionsapply to this solicitation: FAR 52.212-1, Instructions to Offerors -- Commercial Items; 52.212-4, Contract Terms and Conditions -- Commercial Items and 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders -- Commercial Items. Additionally, the following FAR clauses cited in Clause 52.212-5 are also applicable to this acquisition as follows: 52.222.26 "Equal Opportunity"; 52.222-35 "Affirmative Action for Special Disabled and Vietnam Era Veterans"; 52.222-36 "Affirmative Action for Handicapped Workers"; 52.222-37 "Employment Reports on Special Disabled Veterans and Veterans of Vietnam Era"; 52.225-3 "Buy American Act -- Supplies"; 52.225-18 "European Community Sanctions for End Products." Quotes are due June 16, 1997, 2:00 p.m. local prevailing time. Fascimile submissions are not authorized. Submit the following to DHHS, PHS, CDC, NIOSH, ALOSH, Attn: Brenda Goodwin, 1095 Willowdale Road, Morgantown, WV 26505: (1) one original of a completed SF 1449, signed by an individual authorized to bind the organization; (2) a Schedule of Supplies/Services and Pricing for the system being offered, including any optional accessories separately priced; (3) completed Representations and Certifications -- Commercial Items, FAR 52,212-3; (4) descriptive literature for evaluation purposes; and (5) acknowledgment of solicitation amendments, if any. Offers that fail to furnish the required information, or reject the terms and conditions of the solicitation may be excluded from consideration. Award of a purchase order will be made on or before June 30, 1997. Information regarding this notice can be obtained from Brenda Goodwin at (304)285-5882 or by fax at (304) 285-6083. All responsible sources may submit a response, which shall be considered by the Agency. (0141)

Loren Data Corp. http://www.ld.com (SYN# 0355 19970523\66-0008.SOL)


66 - Instruments and Laboratory Equipment Index Page