Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JUNE 2,1997 PSA#1857

Department of Veterans Affairs Medical Center, Chief, Acquisition and Materiel Management (90C), One Veterans Drive, Minneapolis, MN 55417

D -- INSTALLATION OF COMPUTER/COMMUNICATION CABLE SOL RFQ 6-DA-98 DUE 061997 POC Daniel Agrimson 612-725-2178 The VA Medical Center (VAMC), Minneapolis, MN intends to award a contract for cable pulling, faceplate connection, and testing of the cable/faceplate installation. This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in FAR Subpart 12.6, as supplemented with additional information included in this notice. Solicitation #RFQ-6-DA-98 is assigned as Request for Quotes (RFQ) and a written solicitation will not be issued. This announcement constitutes the only solicitation. Solicitation documents and incorporated provisions and clauses are those in effect through Federal Acquisition Circular 90-46. This procurement is a small business set-aside. SIC code is 7373 and the small business size standard is $18.0 million. Contractor shall provide installation of twisted pair cable (category 5, UTP non-plenum) to support data and voice communications at the Minneapolis Veterans Affairs Medical Center, One Veterans Drive, Minneapolis, MN 55417, as follows: Item 1. Install cable drops (twisted pair, category 5, UTP non-plenum) from phone closets to modular faceplate in existing room. Each drop will consist of three (3) 4-pair cables. Two (2) cables will be used for data and one (1) cable will be used for voice. Contractor to use existing cable trays which are located in the interstitial space. Item 2. Install one hundred (100) Modular jacks to 110 Block Patch Panels, in phone closets. Item 3. Punch down 2 data cables to 110 Block Patch Panels and label cables, in phone closet. NOTE: Voice cables will be labeled, but NOT punched down as part of this contract. A tail (minimum of 15 feet), sufficient to reach all walls for future punch down, should be left on each voice cable in the phone closet. Item 4. Install modular faceplate (4 hole); connect 2 data cables (4-pair down to single jack) to 2 separate jacks on faceplate, certify and label; voice cable WILL NOT be connected, but should have a 2 foot coiled tail, with label, placed in wall behind the faceplate. Provide line certification results to medical center technical staff. Specific modular RJ45 jacks will be used as specified below. Voice cable jacks WILL NOT be installed. Item 5: All materials (faceplates, connectors, jacks, blanks, 110-punch down blocks and cable) will be provided by the Medical Center, with the exception of the materials used during installation of cable, as noted in item #10 below. Modular faceplates (4 hole) will be used. 110 Connect Modular RJ45, category 5, jacks will be used. Modular blanks will be used to fill unused modular slots on faceplates (2 per faceplate). Modular jack to 110 Block Patch Panels,category 5, will be used to punch down data cables in phone closets. Hinged wall brackets, provided by the VA, will be used for mounting 110 Block Patch Panels in phone closets. Item 6: Cable installation sites will be marked on a floor plan that will be provided to awarded contractor. Item 7: Average cable pull will be 175 feet. Longest cable pull will be 325 feet. Item 8: A total of 675 cable drops(3 cables to each faceplate) will be pulled. Item 9: All work must comply with the TIA/EIA standards and current low voltage wiring codes. Item 10: Contractor must provide their own tools for cable installation. Items such as cable ties, ceiling ties, ceiling anchors for hanging cables, material to repair firewalls and reseal conduits, and all other items necessary for completion of this job, not mentioned in Item #5 above, are considered installation materials and will be provided by the contractor. Item 11: Contractor must firestop all openings in firewalls, reseal conduits when opened, and perform daily general cleanup. Item 12: This work will be performed over a 30-day period, Monday through Friday (excluding holidays), beginning about June 23, 1997. About 25% of the work may have to be performed between 5:00 pm and 7:00 am. This will be a firm fixed price contract. FOB is Destination. Payment will be made in arrears on certified invoices. Pre-bid site walk will be held on June 5, 1997 at 10:00 am local time. Meet in conference room located in Room 4G-107, VA Medical Center, One Veterans Drive, Minneapolis, MN 55417. Failure to attend this pre-bid conference will not relieve the successful Contractor from compliance with all specifications, terms, and conditions of resultant contract. The following incorporated clauses and provisions are those in effect through FAC 90-46 and are applicable to this acquisition. 52.212-1 Instructions to Offerors -- Commercial Items; 52.212-2 Evaluation -- Commercial Items, 52.212-4 Contract Terms and Conditions -- Commercial Items; 52.212-5 Contract Terms and Conditions Required to Implement Statutes or Executive Orders -- Commercial Items, 52.219-6 Notice of Total Small Business Set-Aside. Evaluation factors include contractor references and pricing. Offerors must include a completed copy of the provision at 52.212-3, Offeror Representations and Certifications -- Commercial Items, with its offer. Original proposals shall be submitted on company letterhead (or on Contracting Officer's preferred form SF-1449) to: Daniel D. Agrimson, Contracting Officer (90C), V.A. Medical Center, Building 70, Room 4G-107, One Veterans Drive, Building 70, Minneapolis, MN 55417 by 4:30 p.m. on June 19, 1997. (0149)

Loren Data Corp. http://www.ld.com (SYN# 0043 19970602\D-0008.SOL)


D - Automatic Data Processing and Telecommunication Services Index Page