COMMERCE BUSINESS DAILY ISSUE OF JUNE 4,1997 PSA#1859USDA-ARS-MWA, Contracting Office, 1815 N. University Street, Peoria, IL
61604 66 -- BRUKER INSTRUMENTS UPGRADE TO NMR SYSTEM SOL 5114-7-3060 DUE
070397 POC Lori J. Houghton (309) 681-6616 The U.S. Department of
Agriculture, Agricultural Research Service, Midwest Area has a
requirement to purchase a High Performance Digital NMR Spectrometer
Console; an AVANCE 360 Console in exchange for AMX 360 console less
BVT-2000, VT dewar/transfer line, probes, rt shims, and SGI
computer/monitor. The above is an upgrade to the existing Bruker NMR at
the US Dairy Forage Research Center, Madison, WI. This is a combined
synopsis/solicitation for commercial items prepared in accordance with
the format in FAR Subpart 12.6, as supplemented with additional
information included in this notice. This announcement constitutes the
only solicitation; proposals are being requested and a written
solicitation will not be issued. Solicitation No. 5114-7-3060 is being
issued as a Request for Proposal. This solicitation document and
incorporated provisions and clauses are those in effect through Federal
Acquisition Circular 90-46. This solicitation is a sole source
procurement to Bruker Instruments, Inc. CLIN 0001 HighPerformance
Digital NMR Spectrometer Console, 1 The salient characteristics that
the AVANCE 360 Console possesses are as follows: Magnet Control System:
Bruker Sample Transport upper shim stack enables high flow rates for VT
gas and includes integral sensors for Bruker Smart Magnet System in
exchange for existing shim stack. Bruker Smart Magnet System shim and
Digital Lock control unit, including: Digital lock frequency
generation, Digital quadrature lock receiver, Fast-field adjustments
with sample and hold, Flexible computer controlled lock regulation
system, Shim Control Boards with ultra-stable high precision, low noise
shim current sources. Bruker Smart Magnet System keyboard control unit,
for full manual and computer automated control of lock, sample spinning
and room temperature shims. Provides extensive flexibility for
customization of shim ranges, magnetic field offset, sample lift rate
and many other parameters. Spectrometer Cabinet: Double width, 19" rack
mounted cabinet with rf shielding and fullfront access to all
sub-assemblies and cabling. RF Section: BLAXH50 transmitter system,
including: 1H, 19F transmitter (3H on request) for observe and
homo/heteronuclear decoupling, 50 Watt pulse power with 10 Watt CW, all
operations under computer control; X-frequency (6-162 MHZ) broadband
transmitter system for X-frequency observe and decoupling; for both CW
and high power pulse operations; 100 Watt pulse power with 25 Watt
linear CW, all operations under computer control; Multilink (tm)
preamplifier, including: 1H preamplifier (BH0240), 2D preamplifier for
lock and 2D observe (BH0243), BB preamplifier (BH0249), Control unit,
Built-in tune/match display; ATR Quadrature detection receiving system
with high dynamic range, 22 MHZ intermediate frequency and inverse
capability; Router (tm) for automated high speed configuration of RF
signals; Frequency synthesizers. Digital Acquisition Control System:
Communication Control Unit with RISC microprocessor, 16 Mbyte buffer
memory, fast dedicated Ethernet link and RS-232 connections for
communications between the spectrometer and the host computer; Timing
Control Unit, ultra fast VME pulse programmer, provides exact timing
and full flexibility in data acquisition with 12.5 nanosec resolution.
Based on Intel i960 RISC co-processor, the TCU allows control of up to
8 FCUs using a master clock frequency of 80 MHZ. Frequency Control Unit
for the F1 channel, interfaced to the VME Bus, for generation of phase,
amplitude, and frequency using Direct Digital Synthesis (DDS). Provides
0.05 degrees phase settability and 0.001 Hz frequency resolution.
Includes 64 Kword wave form memory (256 kW optional) for programming of
experimental sequences (including pulse shaping and composite pulse
decoupling) that are executable synchronously or asynchronously.
Includes Amplitude Shaping Unit for grating and rf amplitude shaping
control of the rf output (BH2070). Frequency Control Unit for the F2
channel, interfaced to the VME Bus, for generation of phase, amplitude,
and frequency using Direct Digital Synthesis. Provides 0.05 degrees
phase settability and 0.001 Hz frequency resolution. Includes 64KWord
wave form memory (256 kW optional) for programming of experimental
sequences (including pulse shaping and composite pulse decoupling) that
are executable synchronously or asynchronously. Includes Amplitude
Shaping Unit for grating and rf amplitude shaping control of the rf
output (BH2070) Receiver Control Unit, interfaced to the VME Bus, for
acquisition of NMR data with oversampling and digital filtering.
Provides > 18 bit effective dynamic range for typical proton
measurement conditions. Includes Intel i960 RISC co-processor and
buffer memory for flexible read time data management and high
throughput acquisition. 16 bit digitizer allowing simultaneous
acquisition with sampling rate of 400 kHz. Industry Standard Host
Workstation: Complete XWIN-NMR software package for acquisition and
processing of 1D, 2D, and 3D NMR data. Includes media, on-line
hypertext manual, and single node-locked license.Also includes printed
manuals for XWIN-NMR general operation, XWIN-NMR pulse programming,
XWINPLOT and ICON-NMR. Probes and Other Features: Gradient Control Unit
interfaced to the VME bus, for simultaneous control of three magnetic
gradient channels with real time generation of gradient shapes. GRASP
(tm) III three axis Gradient Spectroscopy accessory. Includes
ACUSTAR-II (tm) ultra-stable power supply with digital pre-emphasis
adjustment and three channel gradient amplifier (10 amp per channel),
for generation of up to three orthogonal high current gradients.
Requires GCU and GRASP (tm) II or GRASP (tm) III probe with built in
gradient coils. Inverse broadband (BBI) probe (5 mm sample diameter),
1H observe with broadband decoupling coil tunable from 109 AG to 31P
(PH0010). GRASP (tm) III version, including actively shielded X, Y, and
Z-gradient coils for use with GRASP (tm) III accessory. VT range -50 to
+80 C. Receiver upgrade to Digital Quadrature Detection. Virtually
eliminates center spikes, quad images, flicker noise and 60 Hz
interference in all experiments where the spectral width does not
exceed 40 kHz. (BII001) Support and Installation: Two tuitions to
Bruker training courses. Complete set of system documentation and
manuals provided in BASH CDROM format. Complete console installation by
qualified personnel. Standard samples will be provided by Bruker on a
temporary basis for meeting specifications. Delivery to be within 3-6
months after receipt of order to USDA-ARS-MWA, 1815 North University
Street, Peoria, IL 61604. The resultant contract will be FOB
Destination. FAR 52.212-1, Instructions to Offerors -- Commercial, FAR
52.212-2 Evaluation -- Commercial Items, FAR 52.212-3 Offeror
Representations and Certifications -- Commercial Items, FAR 52.212-4
Contract Terms and Conditions -- Commercial Items, and FAR 52.212-5
Contract Terms and Conditions Required to Implement Statutes or
Executive Orders -- Commercial Items apply to this acquisition.
Proposals will be evaluated on price and price related factors. Offer
must include a 45 calendar day acceptance period. Offers are to be
received Not Later than the Close of Business, July 3, 1997 at
USDA-ARS-MWA, Contracting Office, 1815 N. University Street, Peoria, IL
61604. The POC for this acquisition is Lori Houghton, (309) 681-6616.
(0153) Loren Data Corp. http://www.ld.com (SYN# 0216 19970604\66-0001.SOL)