COMMERCE BUSINESS DAILY ISSUE OF JUNE 6,1997 PSA#1861Fleet and Industrial Supply Center, Norfolk Washington Detachment 901
M.Street, S.E. Bldg. 200 4th Flr., Washington Navy Yard, Washington, DC
203 59 -- ELECTRICAL AND ELECTRONIC EQUIPMENT COMPONENTS PURCHASE OF A
HYDROGEN MASER SOL N00600-97-R-2574 POC For a copy of the solicitation,
contact Customer Services Center, 202/433-2951 or you may fax in your
request 202/433-9569; for additional information, contact Ayo H.
Johnson, code 02W1.1F, 202/433-2970; Contracting Officer, Lisa Murtha,
202/685-1864. The Fleet and Industrial Supply Center Norfolk --
Detachment Washington, intends to purchase a Hydrogen Maser, qty 1,
including installation and a minimum 18 month warranty, with an option
for an additional 4 units. Delivery is FOB Destination at the US Naval
Observatory in Washington, DC by 27 March 1999 (see solicitation for
option delivery requirements). The maser shall have a stand alone
frequency standard, with the ability to tune its cavity independently
without the need for input from another standard. The masers must meet
the following minimum requirements: Frequency Drift-less than 1.0E-15
per day; Stability frequency domain; Allan Variance, 2E-13 at one
second going down as t^(-3/5) out to 1000 seconds, less than 3E-15 for
1000 to 10^4 seconds; Power Supply Sensitivity, <1E-14; Frequency
Adjustments-Resolution of better than 1.0E-16 without phase
discontinuity. Remote frequency adjust via RS232 connection; Magnetic
Field Sensitivity -- less than 3E-14 per Gauss; Temperature sensitivity
-- less than 1E-14 per degree Celcius; Barometric sesitivity -- less
than 1E-14 per in. Hg; Power Supply -- AC 110 volt with 150 watt max.
with automatic crossover to its own battery or external 24v DC power;
Instrumentation, remote monitoring and control. Connection made with
RS232 serial link. (0155) Loren Data Corp. http://www.ld.com (SYN# 0319 19970606\59-0017.SOL)