Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JUNE 10,1997 PSA#1863

Oc-Alc/Dir Of Contracting, 3001 Staff Dr Ste 1ag76a, Tinker Air Force Base Ok 73145-3015

28 -- NOZZLE SEGMENT SOL F34601-97-R-53390 DUE 072897 POC For copy, OC-ALC/PKXDA TINKER AFB OK 73145-3015, For additional information contact Larry Tabor/Lpdpb/[405]739-4437 Item 0001 NSN 2840-01-269-9331PL P/N: 6041T55P03, Material: C50tf21 (x40) cobalt Based super alloy Dimension S: Approx 1.9266 inches Wide, approx 8.225 inches long and and approx 1.3266 Thick with an Airfoil starting at 0 inches and. 492 inches. Function: 64 ea of Of the nozzle segments are filteredtogether to form a circle, and direc T gases over the turbine wheel to operate the compressor of the engin 511EA. Applicable to: T64. Destn: Tinker Air Force Base Ok 73145-3015. Delivery: 31 MAR 99 511 ea The approximate issue/response date will be 26 Jun 97. To: General Electric Co, Lynn Ma 01910-0445. No telephone requests. Only written or faxed requests received directly from the requestor are acceptable. All responsible sources solicited may submit a bid, proposal, or quotation which shall be considered. Award will be made only if the offeror, the product/service, or the manufacturer meets qualification requirements at the time of award in accordance with FAR clause 52.209-1. The solicitation identifies the office where additional information can be obtained concerning qualification requirements as cited in each individual solicitation. It is suggested that small business firms or others interested in subcontracting opportunities in connection with the described procurement make contact with the firm(s) listed. Note: While price will be a significant factor in the evaluation of offers, the final contract award decision may be based upon a combination of price and past performance factors as detailed in the solicitation. Note: An Ombudsman has been appointed to hear concerns from offerors or potential Offerors during the proposal development phase of this acquisition. The purpose of the Ombudsman is not to diminish the authority of the program director or contracting officer, but to communicate contractor concerns, issues, disagreements, and recommendations to the appropriate government personnel. When requested, the Ombudsman will maintain strict confidentiality as to source of the concern. The Ombudsman does not participate in the evaluation of proposals or in the source selection process. Interested parties are invited to call the Ombudsman at (405) 736-3273. DO NOT CALL THIS NUMBER FOR SOLICITATION REQUESTS. Note: Faxed solicitation requests can be submitted to OC-ALC/PKXDA, Tinker AFB OK 73145-3015, FAX NUMBER (405)739-5411. See Note (s) 26. (0157)

Loren Data Corp. http://www.ld.com (SYN# 0217 19970610\28-0004.SOL)


28 - Engines, Turbines and Components Index Page