Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF JUNE 25,1997 PSA#1874

DIRECTORATE OF CONTRACTING, ATZC-DOC, 1733 PLEASONTON ROAD, FORT BLISS, TX 79916-6816

54 -- THIS IS A COMBINED SYNOPSIS/SOLICITATION FOR ELEVEN (11) HAZARDOUS MATERIAL STORAGE UNITS. SOL DABT51-97-Q-0614 DUE 070297 POC Purchasing Agent WILSON, SHARRY (915) 568-3423 (Site Code DOCSUP) This is a combined synopsis/solicitation for commercial items prepared in accordance with the format in Subpart 12.6, as supplemented with additional information included in this notice. This announcement constitutes the only solicitation; proposals are being requested and a written solicitation will not be issued. Solicitation DABT51-97-Q-0614 is being issued as a request for quotation. This solicitation document incorporates provisions and clauses are those in effect through Federal Acquisition Circular 90-46. This acquisition is restricted to small business. Standard Industrial Classification code is 3448. Items are to be delivered and accepted at Fort Bliss, Texas. Exact location to be made available at time of award. The following FAR Provisions are applicable to this acquisition: FAR 51.212-1, Introduction of Offerors-Commercial, applies to this acquisition and no additional addenda applies. FAR 51.212-2 Evaluation-Commercial Items is applicable as follows: The following factors shall be used to evaluate offers: Technical, Delivery, Past Performance and Price. The lowest price, technically acceptable product which meets the Government requirements as listed in Line Items 1 through 9 will be considered. Delivery will be evaluated on the contractors ability to initiate delivery within 30 days after receipt of order. Past Performance will be considered as it related to the contractors inability to provide similar items. FAR clause 52.212-3 Offeror Representations and Certifications-Commercial Items (provide with offer). FAR clause 52.212-4 Contract Terms and Conditions-Commercial Items. FAR 52.212-5 Contract Terms and Conditions Required to Implement Statutes Or Executive Orders-Commercial Items. The contractor will be asked to provide a warranty for the structures that are consistent with customary commercial practices. The solicitation is for Hazmat Storage Structures, in the configurations as listed, using the Basic Structure Specifications (BSS) and Optional Equipment Required (OER) descriptions located at the end of the line item descriptions. LI0001 2 each8'x10', Fire rated BSS 1a, 2a, 3, 4(230 GL Sump), 5a, 6 through 13. OER Item 1-1 ea, 2-1 ea, 3-1ea, 4-48 lineal ft, 5-80 sq ft. LI0002-1 each 8'x10', Fire rated, BSS 1a, 2a, 3, 4(230 GL Sump), 5a, 6 through 13. OER Item 1-1 ea, 2-1 ea, 3-1 ea, 5-80 sq ft. LI0003 1 each 10'x12', Fire rated, BSS 1a, 2a, 3, 4(380 GL Sump, 5a, 6 through 13. OER Item 1-1ea, 2-1 ea, 3-1 ea, 5-120 sq ft. LI0004 2 each- 8' x 10' Not Fire rated, BSS 1b, 2b, 3, 4(230 GL Sump) 5b, 6 through 13. OER Item 1-1 ea, 2-1 ea, 3-1 ea, 4-48 lineal ft. LI0005 1 each 10' x 20', Fire rated. BSS 1a, 2a, 3, 4(670 GL Sump) 5a, 6 through 13. OER Items 1 1-ea, 2-2 ea, 6, 9 and 10. LI0006 1 each 10'x12', Fire rated, BSS 1a, 2a, 3, 4(380 L Sump), 5a, 6 through 13. OER Items 1-1 ea, 2-1 ea, 4-66 lineal ft. 6 and 10. LI0007 1 each 10'x12', Fire rated, BSS 1a, 2a, 3, 4(380 GL Sump) 5a, 6 through 13. OER Items 1-2 ea, 2-1 ea, 3-1 ea, 4-66 lineal ft. LI0008 1 each 10'x20', Fire rated, BSS 1a, 2a, 3, 4(670 GL Sump), 5a, 6 through 13. OER Item 1-2 ea, 2-2 ea, 3-2 ea, 4-122 lineal ft (61' in each compartment) and 5-200 sq ft. LI0009 1 each 10'x20', Fire rated, BSS 1a, 2a, 3, 4(670 GL Sump), 5a, 6 through 13. OER Items 1-2 ea, 2-2 ea, 3-2 ea, 4-61 linealft (in only one compartment) 6, 7 and 8. LI0010 Delivery and Off-Loading Charges in connection with the above items 1-9. Specifications for Prefabricted Hazmat Storage Units. Basic Structure Specifications: Free Standing, 9 ft high, re-locatable chemical storage and containment structure. Must meet NFPA 30-1993 Fire Code for storage of flammable and combustible liquids. Must meet Factory Mutual (FM) approved 2-hour fire rating per ASTM E119 (ANSI/UL 263, NFPA 251)test standard. One and one-half hour fire-damper on both intake and exhaust of ventilation systems per NFPA requirements. UL classified; fuse links to provide automatic closure in the event of fire. Includes the following components for storage of flammable or combustible liquids and other hazardous materials: 1a. Two (2) hour fire-rated gypsum on interior walls and ceiling, protected by non-rusting, "galvannealed" steel siding consisting of 12 gauge steel sheathing with 16 gauge formed steel studs. 1b. Non-combustible walls consisting of 12 gauge steel sheathing with 16 gauge formed steel studs. 2a. Two (2) hour fire-rated roof structure consisting of 12 gauge steel deck with 16 gauge formed steel joists. 2b. Non-combustible roof structure consisting of 12 auge steel deck with 16 gauge formed steel joists. 3. 1 1/8" thick coated plywood APA rated drum platform in removable sections for easy access to the spill containment sump. Black enamel painted 6" wide steel grating mount across the wall. 4. A (size as specified on each LI listed above)gallon capacity, 2-hour fire rated sump, continuously seam welded on interior and exterior; surpasses regulatory and Factory Mutual (FM) requirements for spill containment. 5a. One (1) 54"x80" two hour fire-rated double steel wall door. Door hardware includes a 3-pointlocking hardware includes a 3-point locking system. 5b. One (1) 54"x80" steel door. Door hardware includes a 3-point locking system. 6. Natural draft ventilation. Each vent opening is equipped with 1 1/2 hour UL Classified fire dampers. The vent openings are arranged to provide air movement and prevent accumulation of hazardous vapors. 7. Interior surfaces protected with a white chemical-resistant epoxy coated finish. 8. Exterior surfaces finished with satin finish urethane coating for high impact, corrosion, and abrasion resistance. 9. Static grounding and bonding angles for prevention on explosive sparking hazards. 10. Eight (8) ft grounding rod and cable shipped loose for installation by owner. 11. Hazard labeling (DOT "Flammable" Placard, NFPA 704 rating signs). 12. Four (4) inch riser for forklift and/or crane slings and under sump inspections. 13. Four (4) hold-down angles for bolting to owner's foundation for seismic and wind load anchoring. Optional Equipment Required: 1. Removeable steel loading ramp (see LI for quantity required). 2. Explosion-proof light, 150 watt (see LI for quantity required). 3. Explosion-proof 350 cfm mechanical ventilator (see LI for quantity required). 4. Steel shelving, 15" wide, in 3 tiers, on side and back walls (and partitions, where applicable) adjustable (see LI for lineal ft required). 5. Sump line (see LI for SQ FT required). 6. Exterior mounted dry chemical fire suppression system with bell alarm system to central Fire Department (RF signal fire alarm to be installed by owner). 7. Two (2) hour fire-rated partition to divide structure in two compartments. 8. Additional two (2) hour fire-rated 54"x80" double steel wall door, with a 3-point locking system hardware. 9. R-11 insulation on walls and ceiling. 10. Explosion-proof air conditioning unit rated at 14,500 BTU. The offers against this solicitation are due 02 July 1997. Offers should be addressed as follows: Regular mail: Directorate of Contracting, ATTN: Sharry L. Wilson, ATZC-DOC-B(DOE), 1733 Pleasonton Rd., Fort Bliss, TX 79916. If sent FEDEX or UPS use Directorate of Environment, ATTN: Sharry L. Wilson, Bldg 624S, RM 131, Fort Bliss, TX 79916. The outside of your offer must be marked with the RFQ number and indicate that it is only to be opened by Sharry L. Wilson. No FAX or EDI offers will be accepted. POC Sharry L. Wilson TEL (915) 568-3423. (0174)

Loren Data Corp. http://www.ld.com (SYN# 0257 19970625\54-0003.SOL)


54 - Prefabricated Structures and Scaffolding Index Page