COMMERCE BUSINESS DAILY ISSUE OF JUNE 30,1997 PSA#1877VA Medical Center (04-90C), 1201 N.W. 16th Street, Miami, FL 33125 73 -- TITLE: FREEZER AND COOLER COMBINATION SOL 546-09-97 DUE 072197
POC Linda Banko, 305-324-3296 E-MAIL: LEAD, PURCHASING AGENT,
BANKO.LINDA@MIAMI.VA.GOV. THE FREEZER AND COOLER COMBINATION RFQ 546-
09 -97 This is a combined synopsis/solicitation for commercial items
prepared in accordance with the format in subpart 12.6, as supplemented
with additional information included in this notice. This announcement
constitutes the only solicitation; proposals are being requested.
Solicitation RFQ 546-09 -97 is issued as a request for proposal and
incorporates provisions and clauses that are in effect through Federal
Acquisition Circular 46. The Standard Industrial Classification Code
(SIC) is 3585 Small Business Size Standard is 500 Employees Replacement
equipment: 1 Vendor will supply all parts,labor and material for the
complete installation of s combination freezer/Cooler. 2. The freezer
and cooler combination provided under this specification shall be
prefabricated of modular design. Panels shall be constructed to allow
for easy, accurate field assembly with provisions to facilitate future
enlargement or relocation. Equipment shall meet or exceed current
requirements of the following specifications: electrical components
shall meet the requirements of the national electrical code (NEC);
refrigeration components shall meet the specifications established by
the American Society of Heating, Refrigeration and Air Conditioning
Engineers (ASHRAE). Standard panels must be a maximum widths of 48" and
fully interchangeable for ease of installation. Corner panels are in
accordance with the floor plan. Tongue and groove perimeter edge of
panels for proper alignment. All panels shall be provided with cam-
action panel fasteners. Locks shall be in plastic locks with access
hole for hex wrench. Access holes shall be covered with snap caps.
Freezer: insulation shall be a 4" thick class 1, rigid urethane foam,
1.9 to 2.2 lb. Cu.ft. Polystyrene 1.0 lb./cu ft.density. The thermal
conductivity factor ("k") shall not exceed 0.24 btu/h/sq.ft. /degree
f/in. Installation shall be a 97 closed cell structure, UL classified
10 flame spread, 130 smoked developed. The "r" factor for "4"
insulation is 16.4. The exterior wall, and ceiling finish shall be 26
guage, white embossed galvanized steel.and ceiling finish shall be
mill, smooth, stainless steel, no.304,3 finish. The existing building
floor is to remain with no new floor being installed. Door: freezer:
one (1) 5'x7', infitting door, switch with pilot light, electric door
heater, heavy duty chrome hardware, inside safety release handle and
padlock provision on single point latch. Cooler: one (1) 5'x7',
infitting door, switch with pilot light, heavy duty chrome hardware,
inside safety release handle and padlock provision on single point
latch. 2 freezer: 38,800 total btu/h one (1) complete remote mount
system to include: one (1) water cooled condensing unit, 208-230v/ 3
phase/ 60 hz, using r-22 freon balanced with two (2) standard velocity
electric defrost evaporators; sight glass, dryer, pressure control,
expansions valve, industrial thermostat, solenoid, coil, drain heater,
heat exchanger, timer, vibration eliminator; (5) year compressor
warranty (by contractor), and one (1) year parts warranty. Evap units
are 208-230v/ single phase. 3 cooler: 28,600 total btu/h one (1)
complete remote mount system to include: one (1) water cooled
condensing unit, 208-230v/ 3 phase/ 60 hz, using r-22 freon) balanced
with two (2) standard velocity air defrost evaporators; sight glass,
dryer, pressure control, expansion valve, industrial thermostat,
solenoid, coil, vibration eliminator; five (5) year compressor warranty
(by contractor), And one (1) year parts warranty. New installation of
lights in cooler and freezer. 4 misc. Equipment: 0ne (1) remote dial
thermometer per room. Aluminum angle to affix to floor. Mastic sealant
for panel joints. Metal clad ceiling stringer. 0ne (1) presure relief
vent shall be provided to equalize the difference to pressure between
the interior and exterior of the frezer. Optional water regulating
valves for condensing units. 5 Disassemble and remove
refrigerator/freezer structure and all of its components. Installation
of new refrigerator/freezer to include all connections to existing
utilities. These connections need to be coordinated with the VA's
Purchasing Agent technical represenative. Contractor is required to
provide operation/service (maintenance) manuals with each piece of
equipment. The provision at 852.210-70, Service Data Manuals,
852-210-75, Technical Industry Standards (APR 1984), 52.212-1,
Instruction to Offerors-Commercial items; 52.212-2,
Evaluation-Commercial items, the following factors shall be used to
evaluate offers: (1) Price. (2) Warranty. (3) On-site training. (4)
Delivery time. A completed copy of the provision at 52.212-3, Offers
Representations and Certifications-Commericial items, 52.212.-4,
Contract Terms and Conditions -- Commericial Items. 52.212-5 Contract
Terms and Conditions Required to Implement Statutes or Executive
Orders-Commercial Items also apply. 52.222-26, Equal Opportunity (E.O.
11246). 52.222.-35, Affirmative Action for Special disabled and
Vietnam Era Veterans (38 U.S.C.4212). 52.222-36, Affirmative Action for
Handicapped Workers (29U.S.C.793). 52.222-37, Employment Reports on
Special disabled Veterans and Veterans of the Vietnam Era (38
U.S.C4212). 52.225-3, Buy American Act-Supplies (41 U.S.C.10).
52.225-18, European Union Sanction for End Products (E.O. 12849). and
52.232-33 Mandatory Information for Electronic Funds Transfer Payment
(Aug. 1996), Warranty Consideration on parts and labor, Service Manual.
Please submit proposal to Linda Banko, Purchasing Agent at FRMS (90F),
V.A. Medical Center, 1201 N.W. 16th Street, Miami, Florida 33125 on or
before 7/15/97. Faxed proposals will be accepted fax number
305-324-3234. Government will NOT be responsible for any failure
attributed to the transmission or receipt of their proposal. This RFQ
is 100% set-aside for small business concerns. (0177) Loren Data Corp. http://www.ld.com (SYN# 0368 19970630\73-0001.SOL)
73 - Food Preparation and Servicing Equipment Index Page
|
|