COMMERCE BUSINESS DAILY ISSUE OF JULY 7,1997 PSA#1881Commander, Joint Traffic Management Office, 5611 Columbia Pike, Nassif
Bldg, Rm 621, Contracts Support Division, Falls Church, VA 22041-5050 81 -- MODIFICATION OF CONTAINERS, REFRIGERATED AND RELATED EQUIPMENT
SOL N00033-97-R-6731 DUE 070397 POC E. Gregory Dawson (703) 681-5625,
Sarah Wiley (703) 681-9770 The description of the requirement in item
17 of the pre-solicitation notice issued under this number on 1 July
1997 is deleted in its entirety. Substitute the following: 17. (I) THIS
IS A COMBINED SYNOPSIS/SOLICITATION for the lease of commercial items
prepared in accordance with (IAW) the format in Subpart 12.6, as
supplemented with additional information included in this notice. This
announcement constitutes the only solicitation; proposals are being
requested and a written solicitation will not be issued. (ii) This
SOLICITATION NUMBER N62387-97-R-6731 is issued as a request for
proposals (RFP). (iii) The solicitation document and incorporated
provisions and clauses are those in effect through FEDERAL ACQUISITION
CIRCULAR (FAC) #36, and DEFENSE FEDERAL ACQUISITION CIRCULAR (DFAC)
#9. (iv) This solicitation is unrestricted. This SIC code is 3443. (v)
A list of CONTRACT LINE ITEM NUMBER(S) (CLIN(S)) and items are: CLIN
0001 REFRIGERATED ISO CONTAINER 20' ISO FREIGHT RATING
CONTAINERDESIGNATION 1CC ISO SIZE/TYPE CODE 2232 CODE 2232 ALUMINUM
AND/OR STEEL VOLTAGE SYSTEM. CLIN 0001AA LEASE OF CLIN 0001 FOR 180
DAYS. CLIN 0001AB CONTAINER REPLACEMENT PRICE. CLIN 0001AC OPTION TO
LEASE AN ADDITIONAL 180 DAYS. CLIN 0001AD TECHNICAL SERVICE/PARTS
MANUAL FOR CLIN 0001. CLIN 0001AE SPARE PARTS KIT FOR USE WITH CLIN
0001. CLIN 0002 GENERATOR SET FOR USE WITH CLIN 0001. CLIN 0002AA LEASE
OF CLIN 0002 FOR 180 DAYS. CLIN 0002AB GENERATOR REPLACEMENT PRICE.
CLIN 0002AC OPTION TO LEASE AN ADDITIONAL 180 DAYS. CLIN 0003
REFRIGERATED ISO CONTAINER 40' ISO FREIGHT RATING CONTAINER DESIGNATION
1CC ISO SIZE/TYPE CODE 4232 CODE 4232 ALUMINUM AND/OR STEEL VOLTAGE
SYSTEM. CLIN 0003AA LEASE OF CLIN 0001 FOR 180 DAYS. CLIN 0003AB
CONTAINER REPLACEMENT PRICE. CLIN 0003AC OPTION TO LEASE AN ADDITIONAL
180 DAYS. CLIN 0003AD TECHNICAL SERVICE/PARTS MANUAL FOR CLIN 0003.
CLIN 0003AE SPARE PARTS KIT FOR USE WITH CLIN 0003. CLIN 0004 GENERATOR
SET FOR USE WITH CLIN 0003. CLIN 0004AA LEASE OF CLIN 0004 FOR 180
DAYS. CLIN 0004AB GENERATOR REPLACEMENT PRICE. CLIN 0004AC OPTION TO
LEASE AN ADDITIONAL 180 DAYS. CLIN 0005 STRAIGHT FRAME OR GOOSENECK 20'
CHASSIS GVWR 50,000LBS AND OVER. CLIN 0005AA LEASE OF CLIN 0005 FOR 180
DAYS. CLIN 0005AB CHASSIS REPLACEMENT PRICE. CLIN 0005AC OPTION TO
LEASE AN ADDITIONAL 180 DAYS. CLIN 0005AD STATE OF CALIFORNIA CHASSIS
PER DIEM CHARGE (IF APPLICABLE). CLIN 0006 STRAIGHT FRAME OR GOOSENECK
40' CHASSIS GVWR 74,000LBS AND OVER. CLIN 0006AA LEASE OF CLIN 0006
FOR 180 DAYS. CLIN 0006AB CHASSIS REPLACEMENT PRICE. CLIN 0006AC OPTION
TO LEASE AN ADDITIONAL 180 DAYS. CLIN 0006AD STATE OF CALIFORNIA
CHASSIS PER DIEM CHARGE (IF APPLICABLE). CLIN 0007 DELIVERY. CLIN
0007AA DELIVERY OF CLIN 0001 AND CLIN 0002. 0007AB DELIVERY OF CLIN
0003 AND CLIN 0004. CLIN 0006AC DELIVERY OF CLIN 0001, 0002, AND 0005
(COMPLETE SETUP). CLIN 0007AD DELIVERY OF CLIN 0003, 0004, AND 0006
(COMPLETE SETUP). CLIN 0008 HANDLING FEE (IF APPLICABLE). CLIN 0009
DEPOT OVERTIME. CLIN 0010 DAMAGES ARE REIMBURSABLE CHARGES CERTIFIED
UPON REDELIVERY OF LEASED UNITS. CLIN 0011 REEFER MECHANIC (HOURLY
RATE). QTY: 6 UNITS AT CLINS 0003, 0004, AND 0006. 2 UNITS AT CLIN
0011. vi) Description of requirements for the items to be leased by the
Government: The JTMO intends to lease Refrigerated containers that are
not more than seven (7) years old. Containers leased in response to
this synopsis/solicitation shall be fully operational and comply with
International Organization for Standardization (ISO). ISO International
Standards 668, 1161, 6346 and sections of International Standard 1496
applicable to the type of container under lease, and all amendments,
supplements and successors thereto. State of Repair. IICL Guide for
Container Equipment Inspection (most recent edition) and all
supplements and technical bulletins pertaining thereto. Dimensions. All
containers shall be 8 feet wide and 8 feet 6 inches high. Floors.
Except for collapsible, tank and refrigerated containers, container
floors shall be laminated or solid hardwood boards or marine laminated
plywood (1 and 1/8 inch minimum thickness) and comply with current
Australian Department of Health Standards. Containers leased under CLIN
0001 and 0003 shall be the length specified, either 20ft or 40ft, steel
and/or aluminum, and possess the following features or characteristics:
1. Forklift pockets. 2. Interior sidewalls lined with corrugated
stainless steel panels. 3. Floors of raised aluminum T-shaped design.
4. Rear end floors reinforced for forklift truck operation or impact.
5. Drain pans with at least two drain holes. 6. Drain pipes
manufactured of polyvinyl chloride (PVC ) of low thermal conductivity.
7. Refrigeration and heating units operated solely by electricity with
dual voltage capacity. 8. Operation with AC 200V, 3 Phase 50/60 Hz, AC
200V 3 Phase 60 Hz, AC 380/400/415V 3 Phase 50 Hz, or AC 440V 3 Phase
60 Hz power supply, as applicable, subject to normal fluctuation. 9
Equipment controlling temperature between -- __ ____ degrees and +__
____ degrees Fahrenheit or equivalent Celsius temperature. 10.
Thirty-one (31) day cycle temperature recording devices capable of
recording temperatures ranging from -20 degrees to +80 degrees
Fahrenheit and equivalent Celsius temperatures. 11. Two (2) power
cables, each a minimum of fifteen (15) meters long, one rates for 220V
and the other rated for 440V to insure dual voltage flexibility. 12.
Electrical plug as specified in each individual delivery. 13. Spare
parts kits CLIN 0001AE and 003AE as specified (to be inventoried during
on-hire and off-hire inspections with government reimbursing the
contractor for the difference between those furnished and those
returned). 14. In a condition meeting or exceeding the recommendations
of the latest edition of the IICL Guide for Refrigerated Container
Inspection and Repair and all supplements and technical bulletins
pertaining thereto. Chassis furnished to the government may be new or
used, but shall meet thefollowing requirements. All chassis shall meet
the following requirements upon delivery to the government; and upon
return of the chassis to the contractor, the government shall either
restore and repair the chassis to meet such requirements or compensate
the contractor for such restoration and repair: State of Repair. All
chassis delivered and returned shall comply with the latest edition of
the IICL Guide for Container Chassis Inspection and all supplements
and technical bulletins pertaining thereto. FHWA. All chassis shall
have been inspected pursuant to the regulations of the FHWA within
three (3) business days of delivery. Customs. Customs Conventions on
Containers and certification of compliance shall be issued by American
Bureau of Shipping or Lloyds Register. Safety. International
Convention for Safe Containers (CSC) 1972 and U.S. regulations
thereunder. All necessary examinations shall be valid and current for
at least thirty (30) months. Connections must be as follows: #3 Hatch
Forward/after end: (17 fwd), (15 aft) connections -- 30amp/3 phase/250
VAC/3W/4 Pole/ (MIPCO) CAT #263001. #4 Hatch after end: (4) POL/30
Amp/500; VAC/50HZ/IP56/(CAT #5650453), (2) 30 amp/480 VAC/30 4 W/4
Pole/ (MIPCO CAT # IBR343417 NM, (10) ORIGINAL EQUIPMENT/WISKA/32
AMP/IP56/4 POLE. (vii) Date and Place of delivery and acceptance and
FOB point: All units shall be delivered to DSO Philadelphia, 3600 S.
Darien Street, Philadelphia PA 19148. CLIN 0011 shall perform service
at destination address and also MOT Bayonne NJ. Inspection and
acceptance shall be made at destination. (viii) FAR 52.212-1
Instructions to Offerors, Commercial, FAR 52.217-5 Evaluation of
Options, 52.217-6 Option for Increased Quantity are incorporated by
reference and are applicable to this solicitation. (ix) FAR 52.212-2,
Evaluation of Commercial Items (OCT 1995) is incorporated by reference
and applies to this acquisition. ADDENDUM 52.212-2 Para (a) The
following factors shall be used to evaluate offers and are of equal
importance: technicalcapability, price and past performance. (x)
Offerors shall include a completed copy of the provision at FAR
52.212-3, Offeror Representations and Certifications -- Commercial
Items (OCT 1995), with its offer. (xi) FAR 52.212-4, Contract Terms and
Conditions -- Commercial Items (OCT 1995) is incorporated by reference
and applies to this acquisition. Contract Type: Firm Fixed Price
(FFP). (xii) FAR 52.212-5 Contracts Terms and Conditions Required to
Implement Statutes (OCT 1995) is incorporated by reference, however,
for paragraph (b) only the following provisions apply to this
acquisition: 52.212-5 (b), 52.2.3-6 Restrictions on Subcontractor Sales
to the Government with ALT I 1995). 52.203-10 Price or Fee Adjustment
for Illegal or Improper Activity (SEPT 1990), (41 USC 423). 52.219-8
Utilization of Small Disadvantaged and Women Owned Small Business
Concerns (OCT 1995), (15 USC 4212). 52.219-9 Small Business, Small
Disadvantaged and Women Owned Small Business Subcontracting Plan (OCT
1995). 52.222-26 Equal Opportunity, 52.222-35 Affirmative Action for
Special Disabled and Vietnam Era Veterans (APRIL 1984), (38 USC 4212).
52.222-36 Affirmative Action for Handicapped Workers (APRIL 1984), (29
USC 793). 52.222-37 Employment Reports on Special Disabled Veterans and
Veterans of the Vietnam Era (JAN 1988), (38 USC 4212). (xiii)
Additional Requirements: Warranty. The Contractor shall extend to the
Government full coverage of any standard commercial warranty normally
offered in a similar commercial lease, provided such warranty is
available at no additional cost to the Government. Acceptance of the
standard commercial warranty does not waive the Government's rights
under the "Inspection Clause" nor does it limit the Government's rights
with regard to the other terms and conditions of this lease. In the
event of a conflict, the terms and conditions of this lease contract
shall take precedence over the standard commercial warranty. The
standard commercial warranty period shall begin upon final acceptance
of the applicable material and/or services listed in the schedule.
DFARS clause 252-225.0007 Trade Agreements Act. (xiv) DPAS Rating: N/A
(xv) CBD number notes: N/A (xvi) One (1) technical and (1) price
proposal are due not later than 1200 hours EST, 3 July 1997 at the
JTMO, Nassif Bldg., 5611 Columbia Pike, Falls Church, VA 22401-5050.
Alternately, offers may be submitted via facsimile to (703) 681-5625 or
7687. Electronic submissions may be received via the internet at
"dawsong@baileys-emh5.army.mil. Offerors must acquaint themselves with
the new regulations concerning commercial items acquisition. contained
at FAR subpart 12 and must ensure that all Certifications and
Representations are executed and returned as called for in this
solicitation. (xvii) If you intend to participate in this procurement
and require copies of the commercial item description concerning this
specific acquisition, contact E. Gregory Dawson at (703) 681-5625.
(0183) Loren Data Corp. http://www.ld.com (SYN# 0258 19970707\81-0001.SOL)
81 - Containers, Packaging and Packing Supplies Index Page
|
|