|
COMMERCE BUSINESS DAILY ISSUE OF AUGUST 14,1997 PSA#1909USEPA Region I MCP, JFK Federal Building, Boston, MA 02203-2211 66 -- INSTRUMENTS AND LABORATORY EQUIPMENT SOL W7-80005-F1 DUE 090897
POC Kerryanne Diehl, Fran Lewis, Contracting Specialists, (617)
565-4241, FAX, (617) 565-3706. Portable GC/MSD Standard System w/dual
MPV, fixed & removable traps/Membrane/Mass flow meter Cryo cooling/Flat
panel monitor/16MB Ram/Softpack/Hellium Bottle Field Kit w/o libraries.
1/s Dual-stage Turbomolecular, w/Diaphragm Roughing Vacuum Pump/Purge
& Trap Single Sparger & Software/Purge & Trap Single Sparger &
Software/Spectratrak NIST Mass Spectra Library Bundle, (000-411 and
415). 16Mb DRAM installed & tested on SBC (Factory installed only)
Internal Modem & Remote Control Software (28.8KB, V.34) (Factory
installed only). PCMIA Type I-III 3.5" Card socket/Controller. PCMCIA
260MB Removable Hard Drive. Field Operations Maintenance & Supply
Kit/Softpak Instrument Transport case/Softpack Roughing Pump/Accessory
transport case/Instrument Hard Sided Transport case/Roughing
Pump/Accessory Hard Sided Transport case/Custom Commercial Electrical
Generator, 2500 Watts, 110 Volts/Three Day On-Site Installation and
Training (US ONLY) 9 month Warranty Extension following 3 monthwarranty
with upgraded service providing on-site repair service within Zone
B/Custom CTC A200SE GC Autosampler with 100 position rack/Custom
Mounting Hardware, Cabling and Software for CTC A200SE Autosampler,
Custom External Device Interface Kit. Interface Kit for Tekmar 3000
includes injection port and software/Custom Tekmar interfacing. One Day
service engineer time for interfacing SpectraTrak to Tekmar system/HP
Wiley Library of 138,000 Mass Spectra (PBM Format, 84Mb disc
space)/Custom Hard Drive upgrade, 2.1 GB or better/Portable chemstation
(computer) w/remote control software and cable. HP5000 laptop
computer-Pentium based 90 mhz with 16MB RAM, 810 MB Hard Drive, TFT
Color Display and 28.8 Kbaud PCMCIA Modem, or equivalent, Syquest
Transportable Drive w/parallel/VSpectraScan Interface. HP Portable Desk
jet Laser 3 40C. Design Qualifications: The following analysis will be
required: Ambient air toxics-detection level of 1 ppb/v for EPA air
toxics with at least 1L of air sample collected on absorbent. Ambient
air toxics -- Direct injections of 1mL for emergencies and soil gas
analyses. VOA -- Analyze 5mL of water by purge & trap. VOA -- Sparging
capability. BNA -- Spitless injections 1-3 uL of methylene chloride &
hexane extracts. BNA -- autosmapler available. Operating Environment:
Must be capable of operating from field generator for power.
Temperature range-20 to 95F. Humidity up to 100%. Must be rugged to
transported in the back of a truck over a dirt road and not lose
vacuum, tuning, and calibration. Performance (capability): Ambient air
toxics -- Interfacing with a PE or Entch preconcentrator for canister
analysis. VOA -- Interfacing with Tekmar ALS. BNA -- Large volume
injection capability-50uL (thermal concentration). GC: Heated: ambient
to 300C with multiramp programing. C02 capability for sub ambient
cooling. Large enough for a 60m capillary column. Handle 0.2 to 0.5mm
capillary columns with flows 1-5 ml/min. Splitless injector EPC
autosampler capabilities. MS: Range35-600 amu. Sensitivity 5NG of DFTPP
& 5NG of BFB. Must have SIM mode. Scan speed 0.5 to 1 sec for 35-450
amu. Pump down in less than 1 hour to operating condition. Vacuum in
10-5 torr range. Must have an isolation valve. Software: Windows 950S.
Mouse controlled (compatibility with HP Enviroquant is a plus)
Automatic Tune check routines for BFB and DFTPP. Automatic Initial &
Continuous Calibration check routines for %RSD & %D. Automatic TIC
library search routine. Air Toxics: The absorbent tubes must be
transportable to collect the samples apart from the instrument and then
installed for analyses. Desorption temp at least 200 C. IN EMERGENCIES,
MUST BE ABLE TO HAVE FIELD ENGINEER ON SITE WITHIN 24 HR OF INITIAL
CALL. THREE HR TELEPHONE, RESPONSE CALL TO TECHNICAL QUESTIONS 8-5 EST.
MUST HAVE TEST RESULTS (QC) FROM THE MANUFACTURER AS TO THE OPERATIONS
BEFORE SHIPPING. All necessary manuals supplied. Initial start-up
electronic self tests and software validation: Back up copies of
software provided. Required Acceptance tests to confirm the design
qualifications: In House Initial Installation using portable generator:
Tuning (DFTPP & BFG) at 5ng injection -- Must pass EPA's CLP criteria.
Initial Calibration -- Must have less than 20%RDS, CLP criteria for
VOA&BNA. Continuous Calibration & Tuning -- Must have less than 25%
Dover a 10 hr period of operation. QC samples -- Must be within 25% of
the mean accepted value for the VOA and NIST air toxic sample at 1
ppb. Area counts for IS for VOA, air toxics, & BNAs -- 50 to 150 of
mean initial calibration. Field Demonstration for VOA or air toxics.
Instrument must MAINTAIN TUNE OVER A 10 HR PERIOD (DFTPP & BFB)
MAINTAIN INITIAL CALIBRATION OVER A 10 HR PERIOD FOR AIR VOA & BNA
ANALYSES. (0224) Loren Data Corp. http://www.ld.com (SYN# 0511 19970814\66-0012.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|