Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF AUGUST 21,1997 PSA#1914

Defense Supply Center Columbus, PO Box 16595, DSCC-PBAB, Columbus, OH 43216-6595

66 -- AUTOMATED COMPONENT TEST SYSTEM SOL SP071097R0037 DUE 092297 POC Linda Dodson, 614-692-3430 Potential Sources Sought to provide a "turnkey" Automated Component Test System suitable for electrical testing on electronic components, including resistors, capacitors, inductors, relays, and semiconductor devices. The basic system should be an expandable network of controller workstations and test stations. The system should have ISO9000 traceability and should provide on-site calibration capabilities. The controller workstations shall be Windows 95/NT compatible and include software which shall be used for report/program generation, test sequence entry, report entry, data archiving, and statistical analysis. The system should include a Passive Component Test Station for accurate electrical testing of a wide range of resistors, capacitors and inductors. Guidance for parameter measurement ranges and accuracy can be found in active and inactive military specifications which support Federal Stock Classes (FSCs) 5905, 5910, and 5950, MIL-STD-202, and applicable industry standards. The systems should also include a Semiconductor Test Station, capable of complying with MIL-STD-750, Group A Tests, with a test range of 50 Amps Pulsed and 2000 Volts. This station shall test axial lead devices and up to 4 leaded transistors. Required measurement ranges and accuracy can be found in active and inactive military specifications, MIL-STD-202 and applicable industry standards. FSCs supported include 5961 and 5980. In addition, the system shall include a Relay Test Station for accurate testing of a wide range of relays and transformers. The general required ranges, test parameters, and test methods can be found in active and inactive military specifications which support FSCs 5945 and 5950, as well as in applicable industry standards. Finally, the Automated Component Test System shall include a Meter Calibration Test Station. Sources are requested to submit their responses along with technical specification sheets within 30 days after publication of this notice to the following address: Defense Supply Center Columbus ATTN: DSCC -PSBA/Linda Dodson (614) 692-3430 3990 East Broad Street P.O. Box 16704 Columbus, OH 43216-5000 (0231)

Loren Data Corp. http://www.ld.com (SYN# 0349 19970821\66-0023.SOL)


66 - Instruments and Laboratory Equipment Index Page