COMMERCE BUSINESS DAILY ISSUE OF AUGUST 22,1997 PSA#1915U. S. Army Engineer District, Savannah, P.O. Box 889, Savannah, Georgia
31402-0889 C -- ADD /ALTER FAMILY SERVICE CENTER, POPE AFB, NC SOL
DACA21-97-R-0066 DUE 082797 POC ROBERT SMITH, (912) 652-5706 or DAN
LENZ, (912) 652-5585 WEB: Corps of Engineers, Savannah District,
Contracting, http://www.sas.usace.army.mil/. E-MAIL: Sandy Meyers,
Contract Specialist, sandy.meyers@sas02.usace.army.mil/. 1. CONTRACT
INFORMATION: The Savannah District U.S. Army Corps of Engineers
requires the services of an Architect-Engineer firm for Design of
Add/Alter Family Service Center, TMKH003001, Pope AFB, NC. The A-E will
be required to provide site investigation, engineering studies,
preliminary and final design and construction phase services to
completely renovate 2550 sm exiting former NCO club facility into a
Family Service Center. This will be a firm fixed price contract. The
contract is anticipated to be awarded in October 1997 and completed in
July 1998. The estimated construction cost range is $1,000,000 to
$5,000,000. This announcement is open to all firms regardless of size.
For contracting information call Sandy Meyers (912) 652-5324. **** 2.
PROJECT INFORMATION: The selected firm will be required to perform the
following services: site investigation, engineering studies,
preliminary and final design, and construction phase services to
completely renovate 2550 sm exiting former NCO club facility into a
Family Service Center. The center will provide space for family
counseling, mental health counseling, financial assistance,
naturalization classes, cooking classes, airman's attic and household
items loan section. The facility will also provide a chemistry lab for
the education center, a data automation office for the services
squadron, and a Personal Property Processing Office for incoming and
outgoing personnel. **** 3. SELECTION CRITERIA: See Note 24 for general
A-E selection process. The selection criteria are listed below in
descending order of importance (first by major criteria and then by
each sub-criterion). CRITERIA a-f are primary. Criteria g thru i are
secondary and will only be used as "tie-breakers" among technically
equal firms. *** a. Specialized Experience and technical competence in
(1) Design of major building renovation projects. (2) Design of Family
Service Center Facilities. (3) Use of CADD and translation into
Intergraph. (4) Use of MCACES cost estimating. *** b. Past performance
on DoD and other contracts with respect to cost control, quality of
work and compliance with performance schedules. *** c. Capacity to
accomplish the work in the stated contract period and to provide the
following disciplines: architectural, structural, civil, electrical
engineering, mechanical, and a fire protection engineer. Please
disregard the "to be utilized" statement at Block 4 of SF 255 and show
the total strength of each discipline. *** d. Professional
Qualifications of key management and professional staff members. The
design team must include a Registered Fire Protection Engineer whose
principle duties are fire protection engineering or a Registered
Architect or Registered Engineer who is a full member in good standing
of the Society of Fire Protection Engineers (SFPE). *** e. Knowledge
of locality as it pertains in design and construction methods of
projects in the geographic area of this contract. *** f. Demonstrated
success in prescribing the use of recovered materials and achieving
waste reduction and energy efficiency in facility design. SECONDARY
CRITERIA. *** g. Extent of participation of Small Business (SB)
including Women Owned Small Business (WOSB), Small Disadvantaged
Business (SDB), historically black colleges and universities, and
minority institutions in the proposed team, measured as a percentage of
the total estimated effort. *** h. Proximity to the project site. ***
i. Volume of DoD contract awards in the last 12 months as described in
Note 24. **** 4. SUBMISSION REQUIREMENTS: See Note 24 for general
submission requirements. Interested firms must submit ONE (1) copy of
SF 255 (11/92 edition) for prime and ONE (1) copy of SF 254 (11/92) for
prime and all consultants to the following address: US Army Engineer
District, Savannah, ATTN: CESAS-EN-EA, 100 W. Oglethorpe, Savannah, GA
31401-3640, not later than close of business the 30th day after the
date of this announcement. If the 30th day is a Saturday, Sunday, or
Holiday, the deadline is the close of business of the next business
day. NO FAXED SUBMITTALS WILL BE ACCEPTED. FIRMS MUST INCLUDE PRIME's
ACASS NUMBER in BLOCK 3 of SF 255. For ACASS INFORMATION: call
503/326-3459. Cover letters and extraneous materials (Brochures, etc.)
are not desired and will not be considered. The selected firm will be
required to submit a Design Quality Assurance Plan concurrently with
their fee proposal. PHONE CALLS are DISCOURAGED unless ABSOLUTELY
necessary. PERSONAL VISITS for the purpose of discussing this
announcement WILL NOT BE SCHEDULED. This is NOT a REQUEST for a
PROPOSAL. (0232) Loren Data Corp. http://www.ld.com (SYN# 0031 19970822\C-0013.SOL)