Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF AUGUST 26,1997 PSA#1917

National Institutes Of Health, National Institute Of Diabetes & Digestive & Kidney

66 -- TWO CHAMBER DELUZ CALORIMETER FOR MICE WITH ACTIVITY MEASUREMENT SOL NIH-NIDDK-97-294 DUE 091597 POC Marlene T. Mireles, Purchasing Agent, 301-594-8831 Dorann L. Penney, Contracting Officer, 301-594-7733. The National Institutes of Health, (NIH), National Institute of Diabetes and Digestive and Kidney Diseases (NIDDK), has a requirement to purchase a Two Chamber Deluxe Calorimeter for Mice with Activity Measurement and accessories which are necessary for measuring energy expenditure of rodents. The following outlines the specifics for the required acquisition: 1) Calorimeter: Oxymax Main Controller, 2 chamber capacity, Oxygen Sensor (18%-22% range), Carbon Dioxide Sensor (0%-22% range), System Sample Pump, Oxymax v4.0 Software with instruction manual; 2) Oxymax Laptop Controller with cable, pentium 100 MHz, 8 Mbyte Hard Disk Drive, 4x CD ROM Drive, 3 1/2" Disk Drive, 11" Dual Scan Display, Epson FX-870 Printer; 3) Oxymax Fresh Air Ventilation Pump +Pressure, 4) Oxymax Air Flow Ventilation System (1 LPM); 5) Oxymax Chamber-Mice (7.9" x 4" x5") SS Hardware; 6) Oxymax Fast Response Chamber for Mice; 7) Opto-Varimax-Mini Model "B"; 8) Counter Interface to PC/AT 4 Channels; 9) Shipping, Delivery, & Installation Charges. The equipment needed has specifications that must be met and are described in the Request for Quotation (RFQ) Package. All responsible small business sources (which include 8a firms) may submit a quotation, which if timely received, shall be considered by the agency. All requests for quotations must be within the Simplified Acquisition Threshold of $100,000. It is anticipated that the RFQ package NIH-NIDDK-97-294 will be available (fifteen) 15 days after the publication date of the synopsis. Receipt of quotations will be due (ten) 10 days after the release fo the RFQ. The anticipated award date is September 18, 1997. Requests for copies of the RFQ must be in writing and must include vendor name, phone number, and fax number and may be faxed to (301) 480-4226. Quotations must be submitted in writing to the NIDDK, The Natcher Building, 6AN.32, 45 Center Drive, MSC 6600, Bethesda, Maryland, 20892-6600. Quotations will only be accepted if dated and signed by an authorized company representative. (0233)

Loren Data Corp. http://www.ld.com (SYN# 0320 19970826\66-0002.SOL)


66 - Instruments and Laboratory Equipment Index Page