COMMERCE BUSINESS DAILY ISSUE OF AUGUST 26,1997 PSA#1917National Institutes Of Health, National Institute Of Diabetes &
Digestive & Kidney 66 -- TWO CHAMBER DELUZ CALORIMETER FOR MICE WITH ACTIVITY MEASUREMENT
SOL NIH-NIDDK-97-294 DUE 091597 POC Marlene T. Mireles, Purchasing
Agent, 301-594-8831 Dorann L. Penney, Contracting Officer,
301-594-7733. The National Institutes of Health, (NIH), National
Institute of Diabetes and Digestive and Kidney Diseases (NIDDK), has a
requirement to purchase a Two Chamber Deluxe Calorimeter for Mice with
Activity Measurement and accessories which are necessary for measuring
energy expenditure of rodents. The following outlines the specifics
for the required acquisition: 1) Calorimeter: Oxymax Main Controller,
2 chamber capacity, Oxygen Sensor (18%-22% range), Carbon Dioxide
Sensor (0%-22% range), System Sample Pump, Oxymax v4.0 Software with
instruction manual; 2) Oxymax Laptop Controller with cable, pentium 100
MHz, 8 Mbyte Hard Disk Drive, 4x CD ROM Drive, 3 1/2" Disk Drive, 11"
Dual Scan Display, Epson FX-870 Printer; 3) Oxymax Fresh Air
Ventilation Pump +Pressure, 4) Oxymax Air Flow Ventilation System (1
LPM); 5) Oxymax Chamber-Mice (7.9" x 4" x5") SS Hardware; 6) Oxymax
Fast Response Chamber for Mice; 7) Opto-Varimax-Mini Model "B"; 8)
Counter Interface to PC/AT 4 Channels; 9) Shipping, Delivery, &
Installation Charges. The equipment needed has specifications that must
be met and are described in the Request for Quotation (RFQ) Package.
All responsible small business sources (which include 8a firms) may
submit a quotation, which if timely received, shall be considered by
the agency. All requests for quotations must be within the Simplified
Acquisition Threshold of $100,000. It is anticipated that the RFQ
package NIH-NIDDK-97-294 will be available (fifteen) 15 days after the
publication date of the synopsis. Receipt of quotations will be due
(ten) 10 days after the release fo the RFQ. The anticipated award date
is September 18, 1997. Requests for copies of the RFQ must be in
writing and must include vendor name, phone number, and fax number and
may be faxed to (301) 480-4226. Quotations must be submitted in
writing to the NIDDK, The Natcher Building, 6AN.32, 45 Center Drive,
MSC 6600, Bethesda, Maryland, 20892-6600. Quotations will only be
accepted if dated and signed by an authorized company representative.