COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 2,1997 PSA#1921Contracting Officer, USCG Integrated Support Command Miami, 909 S.E.
First Ave., Room 512, Miami, FL 33131-3050 34 -- UNIVERSAL IRON WORKER SOL RFQ 97-HB323 DUE 091297 POC Tony
Sigmon, (305) 536-7418, Contracting Officer, Pat Rodriguez, (305)
536-7401. (i) This is a combined synopsis/solicitation for commercial
items prepared in accordance with the format in Subpart 12.6, as
supplemented with additional information included in this notice. This
announcement constitutes the only solicitation; quotes are being
requested and a written RFQ will not be issued. (ii) Solicitation No.
is RFQ 07-M9323, a request for quotation. (iii) The solicitation
document and incorporated provisions are those in effect through
Federal Acquisition Circular FAC 90-46. (iv) This combined/solicitation
is not under any set aside. The Standard Industrial Classification is
3541 size standard 500. (v), (vi), (vii) One Buffalo Model 1-1/2D
Universal Iron Worker basic machine (must be a direct replacement for
existing shield cup; 10 ea #177-890 shielded tip; 10 ea #177-876
extended tip; 11 ea #180-340 extended electrode; 5 ea #177-878 gouging
tip; 3 ea #177-891 gouging shield; 2 ea #172-886 swirl ring; 3 ea
#177-887 drag shield; 5 ea #171-870 electrode; 6 ea #171-871 tip; 5 ea
#171-872 gouging tip; 2 ea #171-873 stand-off guide; 3 ea #171-874
cup; 1 ea #171-875 electrode wrench; 2 units #903-471 XMT 304 CC/CV
power source to include #131-342 XRA control, #137-550 XR 30A feeder
gun, #042-934 universal cart, #355-ARF-580 regulator/flowmeter, #1/4
SPL 1/4 non-conductive hose, AW14A nut gas hoses, AWN nipple gas hose,
KIC ferrule gas hose, #1/0 ground clamp, LPG 300 ground clamp; 1 ea
#042-388 HF 042388 high frequency unit; 5 ea #24-24 RT cylinder truck;
2 ea #043-007 coolmate radiator; 2 ea #CC-8-042-483 cover for air
pack; 3 ea #042-596 cover for 44D welder; 1 ea #151-086 RCH 14 pin
fingertip control; 2 units #903-219 syncroware 351 power source to
include #004-563 #17 running gear, #042-495 coolmate 1A water cooler,
#043-554 RTCS 14 remote foot control, #151-086 RCE 14 fingerfit remote
control, WP-18-25 TIG torch 350 amp 25 ft., 45V11 power cable adaptor,
#920-928V torch cable cover, #355 ARF 580 regulator/flowmeter, 1/4 SPL
1/4 non-conductive hose, AW14 nut water hose, AW14AR nut gas hose, SWN
nipple gas water hose, KK ferrule gas water hose, #1/0 ground cable,
LPG 300 ground clamp, L1020 cable lug; 2 units #1353-0255-ESAB Miniarc
90I wire pkg to include #31758 gas power adaptor, #WP-17V-12-1 TIG
torch with value 12/2 ft, #355-ARF-580 regulator flowmeter, 50'1/4" SPL
1/4" non-conductive hose, AW14S nut gas hose, AW17 nipple gas hose;
quote must include price for delivery, set up of all equipment and
training Coast Guard shop employees in correct and safe use of
equipment. Quote must also include warranty and repair information.
Offers that do not include this item will be considered non-responsive.
Location is Commanding Officer, USCG Integrated Support Command Miami,
100 MacArthur Causeway, Miami Beach, FL 33139, Attn: Industrial, phone
(305) 535-4485. The required delivery date is 90 days after
receipt/acceptance of order. (viii) FAR provision 52.212-1 Contract
Term and Conditions Commercial Items (Oct 95) is incorporated by
reference. The following clauses are incorporated, FAR 52.219-6 Notice
of Total Small Business Set-Aside (APR 1984), FAR 52.233-2 Service of
Protest (Oct 1995), FAR 52.232-15 Progress Payments not included
(April 1984). (ix) FAR provision 52.212-2 Evaluation -- Commercial
Items does not apply, award will be made to the lowest price for all
items, including delivery, setup of equipment and training. (x) Bidders
shall complete FAR 52.212-3 Offerors Representative and Certifications
-- Commercial Items (Jun 1996) and submit it with their bid. (xi) FAR
52.212-4 Contract Terms and Conditions -- Commercial Items hereby
apply to this solicitation. FAR provision 52.214-4 includes an addendum
incorporating additional clause. (xii) FAR clause 52.212-5 Contract
Terms and Conditions Required to implement Statues or Executive Orders
-- Commercial Items hereby applies to this acquisition, FAR 52.203-6
Restriction on Subcontractor Sales to Government -- Alternative I, FAR
52.203-10 Price or Fee Adjustment for Illegal or Improper Activity,
FAR 52.222.26 Equal Opportunity, FAR 52.222-36 Affirmative Action for
Handicapped Workers, FAR 52.222-37 Employment Reports on Special
Disabled Veterans of the Vietnam Era. NOTICE TO OFFERORS: Reference is
made to enclosure (1) of COMDTINST 4200.49 -- It is the policy of the
Coast Guard to issue solicitation and make contract awards in a fair
and timely manner. To further this policy, the Commandant has created
the position of Solicitation Ombudsman who is empowered to investigate
issues raised by prospective offerors and resolve them, where
possible, without expensive and timely consuming litigation. Potential
offerors who believe that a Coast Guard solicitation is unfair or
otherwise defective should first direct their concerns to the cognizant
contracting officer. If the contracting officer is unable to satisfy
the concerns, the offeror should contact the Coast Guard solicitation
Ombudsman at: Commandant (G-CPM-S/3), 2100 Second Street, SW.,
Washington, DC 20593. Telephone (202) 267-2285, FAX (202) 267-4011.
Potential offerors should provide the following information to the
Ombudsman in order to ensure a timely response: solicitation number,
contracting office, contracting officer and solicitation closing date.
SUBMISSION OF QUOTES: All responsible sources may submit a quote,
which will be considered by this agency. Closing date and time for
receipt of quotes is close of business September 12, 1997, Eastern
Standard Time. Facsimile quotes are acceptable and may be faxed to
(305) 536-3092. Mail shall be addressed to Contracting Officer, USCG
Integrated Support Command Miami, 909 S.E. First Avenue, Room 512,
Miami, FL 33131-3050. All quotes shall be clearly marked with the
solicitation number and the offeror's name. See Note 1. (0240) Loren Data Corp. http://www.ld.com (SYN# 0217 19970902\34-0004.SOL)
34 - Metalworking Machinery Index Page
|
|