COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 2,1997 PSA#1921Naval Surface Warfare Center, Carderock Division, 9500 MacArthur Blvd.,
West Bethesda, MD 20817-5700 66 -- PLANE DYNAMOMETER SOL N0016797Q0306 DUE 091897 POC Fran Cooley,
Contract Specialist, 301-227-5669; Joyce Bell, Contracting Officer,
301-227-1113 Naval Surface Warfare Center intends to negotiate on a
sole source basis with Offshore Structure Analysis INC., 191 E. Weller
Drive, Plainfield, IL 60544, under the authority of FAR 6.302-1. This
is for ten (10) plane dynamometers. The dynamometer body is 3.625
inches along the main axis and 0.900 inches in diameter (including
waterproofing and protection from handling). On one end of the
dynamometer is a shaft 0.500+0.000/0.001 inches in diameter and 1.625
inches long with a 5/16-24 tapped hole 0.875 inches deep. On the other
end of the dynamometer is shaft 0.500+0.000/0.001 inches in diameter
and 2.000 inches long. In this end of the shaft there is a .250 inch
hole for the cable to connect to the strain gages. Intersecting this
hole is a 0.250 inch diameter slot 1.250 inches long to allow the cable
to be bent out of the way so that the end of the shaft can be put in a
blind hole 0.750 inch deep. The dynamometer must be completely
waterproof to a depth of 30 feet of water. The dynamometer is to be
able to measure torque around the main axis and 2 forces that are
perpendicular to the main axis and normal to each other. The full scale
ranges are +/- 100 ponds and +/-100 inch-pounds with an accuracy of 1%,
repeatability of 1%, off axis sensitivity of less than 5%,linearity of
1%. The dynamometer will be powered with 5 volts dc and the output
should be between 1 and 5 volts dc after an amplification of 1000. The
cable from the dynamometer will have a vinyl jacket and have a length
of 10 feet +/-0.5 feet. All linear measurements are +/-0.005 unless
otherwise specified. Offerors that have the ability to provide the
above dynamometers are invited to submit information as to their
capabilities and any other pertinent data to the address above, to be
received no later than 15 days after the date of this notice. No
solicitation document exists; therefore, a request for such document
will not be considered. Award will be made under Simplified Acquisition
Procedures. SEE Note 22. (0240) Loren Data Corp. http://www.ld.com (SYN# 0299 19970902\66-0006.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|