US Army ARDEC, AMSTA-AR-PC, Picatinny Arsenal, New Jersey 07806-5000

99 -- DRYING AND COOLING CHAMBER PLUS SPECIALIZED EXPLOSION PROOF ELECTRICAL SOL DAAE30-97-Q-1341 DUE 091897 POC SONYA RAPPOPORT, CONTRACT SPECIALIST, (973) 724-2775 WEB: US ARMY TACOM-ARDEC Procurement Network, http://procnet.pica.army.mil/procacts.htm. E-MAIL: Sonya Rappoport, srappop@pica.army.mil. 44 -- The drying and cooling chamber will have both a high and low temperature requirement plus specialized explosion proof electrical. Drying and Cooling Chamber Specifications: Temperature Range: -40 degree F to 257 degree F: Refrigeration System: Mechanical Refrigeration with CFC free refrigerant gases. The refrigeration system will employ an air cooled condenser. Accessories: 2" diameter accessory port flow meter and controls to purge chamber with 5 scfm of make up air. Safety Features: Class 1, GroupD and Class II, Groups E, F and G interior and exterior. "X" purging as defined in the National Electrical Code. Heater surface temperature not to exceed 300 degrees F. The chamber will have a 12" diameter relief port. The temperature sensor shall be of explosion proof type. Size: 10cu. ft. workspace diemsions 24"x27"x28, exterior dimensions 48"x84"x74". Utilities: Power 208 volt, 1 phase, 60 cycle Compressed air. Approximately 10 scfm at a pressure between 80 and 100 psig. This is a sole sourse buyto Tenny Environmental, Parsippany, New Jersey. Note 22. (0247)