Loren Data Corp.

'

 
 

COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 12,1997 PSA#1929

U.S. Immigration & Naturalization Service, Administrative Center, Attn: ACLCAP-Contracts, P.O. Box 30080, Laguna Niguel, CA 92607-0080

54 -- PREFABRICATED STRUCTURES SOL ACL-7-B-0085 DUE 092497 POC Contact Point, Judy Morse, 520-670-6871, Ext. 4950; Contracting Officer, H. John Wolfslau IV, 714-360-3180. WEB: Immigration and Naturalization Service, Administrative Center Laguna, http://www.usdoj.gov.ins. E-MAIL: INS, Office of Contracts and Procurement, addwest@Pacbell.net. Provide and deliver, deliver and set up two modular buildings, to the Douglas, Arizona U.S. Border Patrol Station. The buildings will be 24 feet wide by 50 feet in length (24' x 50'). Each building will be manufactured to meet or exceed Commercial Code requirements for the State of Arizona. Minimum design conditions to include: Built to withstand 75 MPH winds, exposure "C" and building type V-n per UBC. STRUCTURAL: Buildings will have outrigger type, minimum 8" all welded steel "I" beam or "C" channel frames, primed and painted. Floors to have 2" x 8", 16" on center joists, placed perpendicular to main runners and securely fastened to the rframes. Underlayment will be 1 1/8" tongue and grooved OSB subfloor securely fastened to joists. Floor coverings will be at minimum 26 oz. Nylon Carpet, Philadelphia Brand (Vocation) or equal. Color light Brown or Tan. Floor bottom to be 4" rubber based by ROPPE or equal. WALLS: Framing to be 6" metal studs 16" on center mechanically fastened to top and bottom plates. Interior finish to be 5/8" sheetrock taped, textured, and painted light beige with matching molding. Exterior finish to be 5/8" LP innerseal with 6" LP innerseal trip, color beige. R19 fiberglass securely fastened to studs. All exterior trim, doors and windows shall be caulked using 20 year caulking. ROOF: Framing -- 8" steel joists, 16" in center. 1'2" OBS Roof Sheathing. 12" overhang on all sides. Finish -- 25 year fiberglass shingle. Support Posts -- None. A steel clear span beam shall be installed at mod lines to support roof, with no interior support columns. Rain gutters will be standard modular type installed above doors and windows. Insulation wil be R30 securely fastened to rafters. EXTERIOR DOORS: All exterior doors shall be 3' x 6'8", 18 gauge hollow metal doors with 16 gauge frames. All doors and frames shall be prepped for entry door locks and dead bolts. Entry lock shall be Schlage Grade 1 lever set style "D" or equal. WINDOWS: Provide 5 windows in Building A (Office Module), and 6 windows in Building B (Classroom Module), as specified in design specification. Windows to be aluminum dual pane, horizontal sliding as made by "Better Bilt" or equal. Window covering shall be horizontal, 1" venetian blinds, color ivory. CEILING: Shall be suspended ceiling with 2' x 4' grid system, 8' finished ceiling height using Armstrong Brand, or equal, ceiling tiles. LIGHTING: Fixtures to be 2' x 4' energy efficient recessed in ceiling with florescent tubes. Approx. 75' candle power at desk height. All fixtures include diffusers, light switching per code, and T8 fixtures with solid state ballast. ELECTRICAL: A separate 120/240 volt AC single phase, three wire panel sized to meet load shall be mounted on each module. Minimum 24 breaker capacity per module. Panels to be located on end of each module adjacent to HVAC. Load center to be NEMA 3R. All wiring is to be Romex, minimum 12AWG. Install electrical outlets as indicated in design specs. GFIC shall be installed in bathrooms per code and industry standards. All electrical boxes to be metal. Install a junction telephone box with cover and a computer junction box with cover for future computer service. Conduit (3/4") to stub out below trailer. No wiring is required. Install hardwired (with battery backup) smoke detectors in each modular, securely fastened to wood/metal block. HVAC: A thermostatically controlled electric heat and air conditioning (heat pump) unit, manufactured by "Bard" or equal, will be installed in each module. Ducting shall be galvanized metal, branch ducting with Insulated Flex duct with 1" insulation installed above ceiling. Air supplied by ceiling mounted registers. Air return to be ceiling mounted and located for maximum efficiency. Thermostats to be "Honeywell" programmable or equal. Centrally located with fax switch for continuous fan air circulation if desired. INTERIOR WALLS: Walls will be finished with 1/4" taped, textured and painted sheetrock, securely fastened to studs. Interior walls shall extend to top. Sheetrock and insulated. Color beige. Interior doors shall be 1 3/4" x 6'8" solid core wood with metal frames by "Timely" or equal. Prefinished and painted Oxford Brown. Insulation shall be R-11. Doors shall have commercial grade standard entry door locks. Rest shall have privacy door locks. RESTROOMS: Each rest room shall include a toilet, sink, mirror, exhaust fan, light switching, and washable interior walls. Accessories in rest rooms shall include: "Bobrick" for toilet tissue dispenser, paper towel holder, mirror, and soap dispenser. Restrooms shall be equipped with standard handicap fixtures. PLUMBING: Each modular shall have a 5 gallon, 110VAC electric water heater installed above ceiling. All water manifolding shall be provided and installed by mobile manufacturer for single point of entry. All supply lines on the exterior of the modular unit shall be adequately wrapped with standard foam insulation to prevent freezing. Actual water hook up to be made by others. All supply lines shall be copper. All waste manifolding shall be provided and installed by mobile manufacturer for single point of exit. Waste lines shall include sewer hook up. Hook up to be made by others. STEPS: Metal steps of normal industry standards shall be furnished for each exit door. DESIGN SPEC: Each building will contain two bathrooms side by side, containing a toilet, sink, and appropriate plumbing and dispensers. Building A (Office Modular) will be open, with no partitions other than the bathroom walls. This building will have 5 windows of not less than 46" x 38" dimensions. Three windows will be equally spaced on the one side of the length of the building. The opposite long side of the building will contain 2 doors with 2 windows equally spaced on the wall between the doors. This building will contain an electrical outlet located every 8 feet along both long walls and will contain 4 electrical outlets (flush to floor) located in the floor of the building at the centerline, lengthwise. Building B (Classroom Modular) will contain a 10' x 24' office at one end with a partitioned wall and door. The other end of the building will contain the 2 bathrooms in a corner, with the rest of the building open without partitions. The building will contain 6 windows, of not less than 46" x 38", 3 located equally spaced along one length of the building, 1 centered on the short outside wall containing the office, 1 on the other short wall to side of the bathrooms, and 1 on the other long wall between 2 doors. The doors shall be placed on the long wall so as not to allow outside entrance to the 10' x 24' office. The building will contain 4 electrical outlets along the walls fo the office and n o less than 12 outlets equally spaced on the walls around the open area. MISCELLANEOUS: Contractor to furnish piers and other related materials for set up. Tires, tongues and axles shall remain the property of the U.S. Government. DELIVERY PLANS: Final delivery shall be within 90 days after the date of award of the contract. Delivery must be coordinated with the Douglas Border Patrol Station.Receiving hours 9:00am to 2:00pm, Monday through Friday. The Government must be notified 72 hours in advance to ensure receiving personnel are on site. Deliver to U.S. Border Patrol Station, 1051 Lawrence Ave., Douglas, AZ 85608. Delivery to include set up, level and installation of modular units. Remove tires, tongue and axles. Tires, tongue and axles to remain property of the U.S. Government. Tires, tongue and axles to be placed under unit prior to installation. Furnish and install LP innerseal skirting to match exterior finish on building, finish by code. This solicitation document and following incorporated provisions and clauses are those in effect through Federall Acquisition Circular 90-46; FAR 52.233-1 Disputes; FAR 52.202-1 Definitions; FAR 52.212-1 Instructions to Offerors-Commercial Items; FAR 52.212-2 Evaluation-Commercial Items, para(a) is filled in as follows: The Immigration and Naturalization Service/ACLCAP will award a contract resulting from this solicitation to the responsible offeror whose offer conforming to solicitation will be most advantageous to the Government, price, and other factors considered; FAR 52.212-3 Offeror Representations and Certifications-offerors must include a completed copy with their offer; FAR 52.212-4 Contract Terms and Conditions-Commercial Items; FAR 52.212-5 Contract Terms Required to Implement Statutes or Executive Orders-Commercial Items, para(b) the following clauses are applicable: FAR 52.203-6 Restricitons on Subcontractor Sales to the Government, with Alternate 1; FAR 52.203-10 Price or Fee Adjustment for Illegal or Improper Activity; FAR 52.219-8 Utilization of Small Business Concerns and Small Disadvantaged Business Concerns; FAR 52.219-9 Small Disadvantaged and Women-Owned Small Business Subcontracting Plan; FAR 52.222-26 Equal Opportunity; FAR 52.222-35 Affirmative Action for Special Disabled and Vietnam Era Veterans; 52.222-36 Affirmative Action for Handicapped Workers; FAR 52.222-37 Employment Reports on Special Disabled Veterans of the Vietnam Era; FAR52.201-1 Officials Not to Benefit; FAR 52.225-3 Buy American Act Supplies; FAR 52.232-33 Mandatory Information for Electronic Funds Transfer of Payment. This CBD notice/solicitation can be viewed and downloaded via the INTERNET. The preferred method of distribution is via the Internet or by E-Mail request from addwest@Pacbell.net. Receipt of this notice/solicitation package through the Internet in its entirety and bears no responsibility for data errors resulting from transmission or conversion processes. Questions and requests for layout sketches should be directed by way of fax transmittal to 520-670-5805, Attn: Judy Morse. Site Visits may be arranged during normal working hours by contacting: Gilbert Estrada, 1051 Lawrence Ave., Douglas, AZ 85608, 520-670-6714. Prices Preferred as FOB Destination: Douglas, AZ. Vendors bidding FOB ORIGIN must include shipping/handling. This solicitation is issued as an Invitaiton for Bid (IFB) and is full and open competition. The SIC code is 5271. Bids are to be submittedto the Immigration and Naturalization Service, Administrative Center Laguna/ACLCAP, 5th Floor, 24000 Avila Rd., Laguna Niguel, CA 92677, Attn: John Wolfslau, NO LATER THAN 2:00pm pdt, 09/24/97. (0253)

Loren Data Corp. http://www.ld.com (SYN# 0250 19970912\54-0003.SOL)


54 - Prefabricated Structures and Scaffolding Index Page