COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 15,1997 PSA#1930Department of the Treasury, Bureau of Alcohol, Tobacco and Firearms,
Acquisition Division, Room 3290, 650 Massachusetts Ave., NW,
Washington, DC 20226 66 -- LABORATORY X-RAY EQUIPMENT POC Contact Brian Wilkins,
202/927/7715, Fax: 202/927/8688 The Bureau of Alcohol, Tobacco and
Firearms (ATF) intends to acquire "BRAND NAME OR EQUAL" to the EAGLE
U-Probe Energy Dispersive System, (QTY 1 Each). Specifications are as
follows: Base Spectrometer: Mo Microfocus X-ray tube with enclosure,
300 um Cylindrical Capillary, H-V Generator, 1-40 kV adjustable 1 kV
steps Stability <0.01% 1 to 1000 uA adjustable 10uA steps Stability
<0.01% up to 40 Watts tube power, Sampler Chamber, X-Y-Z Sample
positioning system with 50um precision, Video System with 2 Cameras
(magnification: approx. 10X and 100X) crosshair, Vacuum System with
Vacuum Pump (5m3/h) 11/230V, Vacuum sensor Oil Dust Filter and PC
Controlled Value, Sample Illumination with White Fluorescent Light.
EDXRF Software including: Peak labels and KLM line markers, Automatic
EDS spectral peak is program, Interactive periodic table,
User-selectable display colors, User-definable spectral window, Auto
Analysis-Automatic collection, qualitative and qualitative analysis or
single or multiple samples. Spectral Math-Escape peak subtraction,
addition, subtraction and scaling of spectrum. Quantitative analysis
software with DXCOMB software for interactive selection of element
slope, background correction factors and standards and Lucas-Tooth Pyne
Multi-standard, regression analysis software. Standard Be Window
detector: Standard Beryllium window Si (Li) detector for analysis of
elements from Na to U with detector bias cut-off for protection against
accidental warming. DXCOAT software: Software for X-ray analysis of
coating. The package allows for determination of both coating thickness
and composition. Rhodium anode X-ray tube for general use: In lieu of
the Mo tube. Binocular with Zoom Option. Mapping Software & Hardware.
Trade-in of existing MAX. Delivery shall be F.O.B. Destination to
Atlanta, GA 30345. Awardee must complete a SF-3381 ACH Vendor
Miscellaneous Payment Enrollment form, for payment via electronic funds
transfer. Award will be based on price if all technical specifications
are comply with. All interested parties must submit a quote to include
product literature and specifications within 15 days after date of
publication. Quotes are accepted by mail and/or facsimile at
202-927-8688 ATTN: Brian Wilkins. No solicitation available. No
telephone request or inquires will be accepted. (0254) Loren Data Corp. http://www.ld.com (SYN# 0275 19970915\66-0009.SOL)