COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 17,1997 PSA#1932Fluor Daniel Fernald, P.O. Box 538704, Cincinnati, OH 45253-8704 Y -- DISPOSAL FACILITY SOL FSC614 DUE 110797 POC David Sablosky, (513)
648-5162 -- Fluor Daniel Fernald (FDF), RFP No. FSC 614 is scheduled
to be released in November 1997 for the Southern Waste Units (SWU)
Excavation/ On-Site Disposal Facility (OSDF) Phase II at the Department
of Energy's Fernald Environmental Management Project (FEMP), Hamilton
County, Ohio. The Southern Waste Units Excavation/ On-Site Disposal
Facility Phase II contract will consist of a base year and two option
years. The scope of work for the Southern Waste Units Excavation/
On-Site Disposal Facility Phase II shall include, but not be limited
to: erosion and sediment control, dust control, excavation and
transportation of approximately 340,000 cubic yards of impacted
material and placement of that material into the OSDF, placement of
approximately 115,000 CY of debris into the OSDF, construction of the
composite liner system for two (2) disposal cells including horizontal
wells, installation of High Density Polyethylene (HDPE) pipe and
appurtenances for the leachate collection and detection systems,
placement of approximately 80,000 bank cubic yards of impacted material
(from stockpiles at the site) and construction of support facilities.
The contractor shall provide personnel, supervision, facilities,
equipment, material, supplies and services for performance of this
contract. The successful contractor will be required to comply with the
terms and conditions of the FEMP Site Project Labor Agreement for Union
Construction Labor Forces. The contractor must perform at least 55% of
the Contract Value of this project with its own forces. To be
pre-qualified to submit a proposal for this work, a prospective
contractor must provide a release letter to authorize release of
performance data to FDF and a list of (minimum two, maximum nine -- two
projects that satisfy all criteria or up to nine projects that each
satisfy individual criterion) projects that meet the criteria listed
below. The list shall include: (a) project name, brief description of
actual work performed and year project completed; (b) the locationor
work, name of owner's representative and telephone number for the
project owner; the total dollar value of the project; (d) the contract
value for work performed by the prospective contractor; (e) a listing
of major equipment used by the prospective contractor for the
projects. The following are the criteria: 1. The contractor must be
able to demonstrate a successful record of safe construction
performance by a current workers compensation experience modification
rate (EMR) of less than or equivalent to 1.05 or the trend for the past
three years is downward and none of the past three years has an EMR
greater than 1.25. This criterion shall be met by the prime
contractor(s) (EMR of the total corporation) and all other
subcontractors performing work in the field as part of this contract.
In order to assist FDF in pre-qualifying potential offerors,
contractors shall complete the Safety History Form. Contractors shall
also submit a Safety History Form for each particpating joint venture
firm and/or teaming partner. FDF will review the information and
determine a contractor's eligibility for pre-qualification 2.
Experience in the excavation and transportation of contaminated soil
and debris (radiological, RCRA and/or solid waste) for at least two (2)
projects of 100,000 CY (minimum) of material each over a one year
period or one (1) project of 200,000 CY (minimum) of material over a
two year period. The project(s) must have been completed 1990 to
present. The contractor must have self-performed 55% of the contract
value of each project. 3. Experience with placement in a landfill or
cell of soil, soil-like material and/or debris (debris must include
structural/building debris) for at least two (2) projects of 100,000 CY
(minimum) of material over a one year period or one (1) project of
200,000 CY (minimum) of material over a two year period. The project(s)
must have been completed 1990 to present. The contractor must have
self-performed 55% of the contract value of each project. Experience in
the placement of radiologically contaminated debris is preferred. 4. At
least two (2) projects with a minimum contract value of $5 million each
or one (1) project with a minimum contract value of $10 million. The
project(s) must have been completed 1990 to present. 5. Experience in
processing, moisture conditioning and placement of clay liner for at
least two (2) projects of 50,000 CY (minimum) each or at least one (1)
project of 100,000 CY (minimum). For each of these projects, the
Contractor must have self-performed 55% of the contract value of the
project. 6. Experience in the installation of geosynthetic liner for at
least two (2) projects of 10 acres (minimum) each or at least one (1)
project of 20 acres (minimum). 7. One of the projects that satisfy the
above criterion must have been for a Federal Agency (DOE, DOD, Corps
of Engineers, etc.). 8. At least one (1) of the projects that satisfy
criteria 2 through 4 must include the contractor's work force using
level C personal protective equipment including full face air-purifying
canister-equipped respirators. 9. For each project submitted, the
contractor must be able to demonstrate successful performance based on
quality, cost and schedule. FDF will evaluate the response from the
project owner(s) and/or other contacts relative to the listed criteria
in order to verify successful performance of the project. Firms
interested in this work must meet all of the above defined criteria to
be eligible to submit a proposal. The estimated total cost for the
project, including option years, is $20 million to $30 million. Bid
guarantee required. Pre-Qualification Forms and release letter format
are available at the Fluor Daniel Fernald Home Page,
http://www.fernald.gov. The Pre-Qualification Form and release letter
are to be filled out completely by the interested firms and returned to
Mr. David Sablosky at Fluor Daniel Fernald, P. O. Box 538704, Mail Stop
44, Cincinnati, Ohio 45253-8704 no later than October 10, 1997.
Qualified firms will be notified approximately October 31, 1997. The
Solicitation will be available approximately November 7, 1997 at the
Fluor Daniel Fernald Home Page; http//www.fernald.gov. The exact
closing date will be established by the Solicitation. All pre-qualified
sources may submit a proposal which will be considered; only
pre-qualified contractors and/or pre-qualified teaming partner
arangements will be considered. Contractors with questions may contact
Mr. Sablosky at either (513) 648-5162, or E-mail address
andrew.sablosky@fernald.gov. (0258) Loren Data Corp. http://www.ld.com (SYN# 0144 19970917\Y-0005.SOL)
Y - Construction of Structures and Facilities Index Page
|
|