COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 18,1997 PSA#1933Department of the Navy, NAWCAD Contracts Competency Division, Villa
Road, Bldg. 8110, St. Inigoes, Maryland 20684-0010 54 -- UTILITY TRANSPORT TRAILER SYSTEMS SOL N00421-97-R-1427 DUE
091897 POC Chris Hampel, Contract Specialist (301) 862-8894 or William
Case, Contracting Officer (301) 862-8641 This is amendment#10 to the
combined synopsis/solicitation number N00421-97-R-1427, posted
September 12, 1997. The purpose of this amendment is to (1)answer
questions received concerning the solicitation, (2) clarify a previous
specification and (3) reiterate and clarify the basis for evaluation.
Questions and Answers numbered 1-5 were published in Amendment#8 of
this solicitation on September 8,1997. QUESTION#6:Can you specify a
power input connector that would connect to the shore power; can you
provide a part number for the 3-phase 60 amp wall mount inlet per
MIL-C-22992? ANSWER#6: The Government only requires that the vendor
provide the panel mount connection on the trailer/generator. The mating
cable is not required to be provided under this solicitation; AC input
part number is MS90558C32412P. QUESTION#7: Are the tires included in
the maximum width? Or does the max width describe the trailer bed?
ANSWER#7 Yes, the tires are included in the maximum width. The
following CLARIFICATION#1 is provided: For this solicitation the
standard EEI Model ECU 96269/2 is required; no additional features are
required. The following is REITERATED from Amendment#9 August 26,1997
of this solicitation: Evaluation and source selection will be based on
price competition among proposals that meet the Government's minimum
requirements described in this solicitation and therefore the following
factors will be used to evaluate offers: (1) fully meets requirements
of the salient characteristics identified and (2) Low Cost. The offeror
must provide a quote and sufficient technical documentation to
substantiate their claim of compliance with the salient
characteristics. Technical acceptability will be determined solely on
the content and merit of the information provided in response to this
solicitation. This amendment adds the following CLARIFICATION#2: the
technical documentation must include (a) engine Lister-Petter Model
LPWT4A9 (b) electric generator Marathon Model 282PSLI505 and (c) EEI
ECU Model 96269/2. A technical proposal that offers other than the
brand name and model identified will be considered technically
unacceptable. Therefore, offers proposing "brand name/or equal" models
will be considered technically unacceptable. All other conditions
remain unchanged. For information regarding this amendment contact
Chris Hampel (301) 862-8894 (0259) Loren Data Corp. http://www.ld.com (SYN# 0213 19970918\54-0001.SOL)