COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 18,1997 PSA#1933NCCOSC RDTE Division, Code D214B, 53570 Silvergate Avenue, Bldg. A33,
San Diego, CA 92152-5113 66 -- ELECTRICAL & ELCT MEAS & TEST INSTRUMENT SOL N66001-97-Q-0202
DUE 093097 POC Purchasing Agent, Ms. Angela King, Code D222,
(619)553-5829. Contracting Officer, Ms. Cindy Frison, (619)524-2354.
This is a re-advertisement of RFQ N66001-97-Q-0192, for one (1) each
Portable LLS Analyzer per these specifications: 1. Self contained and
portable unit, 2. Must passively tap, monitor and record activity on
two (2) MIL-STD-1397 type E interfaces (4 cables: 2-input and
2-output), 3. Must verify compliance to MIL-STD-1397 type E, ie.,
over-voltage, non-LLS waveform conditions, 4. Record LLS in real time
without interrupting the system, 5. Provide time tagging of events at
least 60ns or faster, 6. Provide triggering capabilities for the
following frame events: *data information frame events: state 0,1,x of
any NTDS data bit; state 0,1,x of word identifier bit. *data
information transfer type-off, single word, burst, combination, any
transfer state 0,1,x of direction indicator. *data information frame
errors-none, parity, number of bits, sync-bit, any error, don't care.
*control frame events: state 0,1,x of any bit for each direction.
*control frame change of state of any bit for each direction. *control
frame errors-none, number of bits, sync-bit, any error, don't care.
*non-valid frame events: off, under voltage, over voltage, non-NTDS,
combination, noise. 7. Select between internal triggering (as defined
above) and external source. 8. Provide external triggering to another
test device. 9. Built-in display/data entry shall allow to setup the
unit browse through setup and data. 10. Decode all control frame
(SIS/SOS) and information frame values. 11. Provide a buffered port on
each input and output cable to see LLS waveforms on an oscilloscope.
12. Provide port to generate a hard copy of captured events. 13.
Operators Manual. Advise on availability. Delivery to made FOB
Destination to: NCCOSC RDT&E Div., 53605 Hull Street, San Diego, CA
92152-5410. Quotations sent via the U.S. mail should be mailed to:
NCCSOC RDT&E Div., Code D222, Bldg. 33, Rm. 0601, Attn: Angela King,
53605 Hull Street, San Diego, CA 92152-5001. All quotations not sent
through the U.S. mail can be faxed to (619)553-5996. "No RFQ will be
prepared or made available for distribution." Award will be based on
technically acceptable low bids received in response to this CBD
advertisement. Competitive awards may be based on the evaluation
criteria stipulated in the Red, Yellow, Green (RYG) Contractor
Evaluation System. The evaluation criteria is available upon request.
Questions may be directed to Angela King at (619)553-5829. Facsimile
quotations are acceptable and must be received on or before the COB on
the closing date stated above at 1500 PST. Facsimile quotations may be
sent to (619553-5996. The applicable Standard Industrial Code (SIC) and
size standard is: 3825 -- 500 employees. (0259) Loren Data Corp. http://www.ld.com (SYN# 0261 19970918\66-0016.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|