COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 30,1997 PSA#1941US Army, CECOM Acquisition Center, Ft. Monmouth, New Jersey 07703-5008 61 -- 100/200 KW TACTICAL QUIET GENERATORS (TQG) DUE 102597 POC Point
of Contact -- Mr. Dorin Morar (703) 806-7343, DOD Project Manager --
Mobile Electric Power, Springfield, Virginia 22160-3199. E-MAIL: Mobile
Tactical Quiet Generators, Morar@Belvoir.army.mil. This is a Market
Survey to locate potential sources for commercially available
electrical generator sets meeting the performance requirements stated
below. The firms answering shall supply the following technical data of
their respective hardware: dimensions(Length x Width x Height), dry
weight, wet weight, coolant capacity, oil capacity, fuel tank capacity
and fuel consumption at rated load. The response shall include
information about price, quantity discounts ans scope of commercial
warranty. Also include logistics related information such as
reliability and maintainability performance (mean time between failure,
maintenance ratio, etc), past history of warranty repair, preventative
maintanence requirements, etc. This notice is for planning purposes
only, and shall not be construed as a Request for Quotation (RFQ) or an
obligation on the part of the Government to make any follow-on
acquisition. The Government does not intend to award a contract on the
basis of responses to this notice or otherwise pay for the information
solicited. No entitlement to payment of direct or indirect cost or
changes by the Government will arise as the result of submission of
responses to this notice and Government use of this information.
Performance requirements for 100 kW Electrical Generator Sets: Fuel
Requirement Diesel (DF1, DF2, JP-8) Diesel (DF1, DF2, JP-8) Pwr@Sea
level & 120 deg. F, 4000ft & 95 deg. F: 100kW, O.8 pwr/fctr 100kW,0.8
pwr/fctr Frequency 50/60Hz 400Hz Altitude Degradation(4000-8000 ft):
3.5% per 1000 ft 3.5% per 1000 ft Climatic Conditions -25 deg. F to 120
deg. F -25 deg. F to 120 deg. F Maximum Power: 110% rated power 110%
rated power Voltage Waveform Deviation(max): 5% 5% Single Voltage
Harmonics(max): 2% 2% Voltage Modulation(max): 1% 1% Voltage
Regulation(max): 1% 1% Short-term Voltage Stability(30 sec): 1% plus or
minus 1% p/m Long-term Voltage Stability(4hr): 2% plus or minus 2% p/m
Dip and Rise for Rated Load(max): 15% rated voltage 12% rated voltage
Recovery Time: 0.5 sec 0.5 sec Dip for Low Power Factor Load(max): 30%
no-load voltage 25% no-load voltage Recovery Time: 0.7 sec to 95% of
no-load voltg 0.7 sec to 95% of no-load vltge Voltage Adjustment Range
120/208V Connection: 50Hz 190-213V, 60 Hz 197-240V 197-229V 240/416V
Connection: 50Hz 380-426V, 60 Hz 395-480V 395-458V Frequency
Regulation: 0.25% 0.25% Short-term Frequency Stability(30 sec): 0.5%
plus or minus 0.5% p/m Long-term Frequency Stability(4hr): 1% plus or
minus 1% p/m Frequency Undershoot w/Load Change(max): 4% 1.5% Recovery
Time: 2 sec 1 sec Frequency Overshoot w/Load Change(max): 4% 1.5%
Recovery Time: 2 sec 1 sec Frequency Adjustment Range: 48-52 Hz, 58-62
Hz 390-420 Hz Aural signature Less or equal to 70 dBA @7m Less or
equal to 70 dBA @7m Performance requirements for 200 kW Electrical
Generator Sets: Fuel Requirement Diesel (DF1, DF2, JP-8) Diesel (DF1,
DF2, JP-8) Pwr@Sea level & 120 deg.F, 4000ft & 95 deg. F) 200kW, 0.8
pwr fctr 200kW,0.8 pwr fctr Frequency 50/60Hz 400 Hz Altitude
Degradation(4000-8000 ft): 3.5%per 1000 ft 3.5% per 1000 ft Climatic
conditions -25 deg. F to 120 deg. F -25 deg. to 120 deg. F Maximum
Power: 110% rated power 110% rated power Voltage Waveform
Deviation(max): 5% 5% Single Voltage Harmonics(max): 2% 2% Voltage
Modulation(max): 1% 1% Voltage Regulation(max): 1% 1% Short-term
Voltage Stability(30 sec): 1% plus or minus 1% p/m Long-term Voltage
Stability(4hr): 2% plus or minus 2% p/m Dip and Rise for Rated
Load(max): 15% rated voltage 12% rated voltage Recovery Time: 0.5 sec
0.5 sec Dip for Low Power Factor Load(max) 30% no-load voltage 25%
no-load voltage Rec. Time: 0.7sec to 95% of no-load voltage 0.7sec to
95% of no-load vltg. Voltage Adjustment Range 120/208V Connection: 50
Hz 190-213V, 60 Hz 197-240V 197-229V 240/416V Connection: 50 Hz
380-426V, 60 Hz 395-480V 395-458V Frequency Regulation: 0.25% 0.25%
Short-term Frequency Stability(30 sec): 0.5% plus or minus 0.5% p/m
Long-term Frequency Stability (4 Hr): 1% plus or minus 1% p/m Frequency
Undershoot w/Load Change(max): 4% 1.5% RecoveryTime: 2 sec 1 sec
Frequency Overshoot w/Load Change(max) 4% 1.5% Recovery Time: 2 sec 1
sec Frequency Adjustment Range: 48-52 Hz, 58-62 Hz 390-420 Hz Aural
signature Less or equal to 70 dBA@7m Less or equal to 70 dBA@7m Point
of contact is Mr. D. Morar, DOD Project Manager, Mobile Electric Power
7798 Cissna Road, Suite 200 Springfield, Virginia 22150-3199.
Telephone number area code, (703) 806-7343. Response due NLT date shown
above. (0269) Loren Data Corp. http://www.ld.com (SYN# 0192 19970930\61-0005.SOL)
61 - Electric Wire and Power and Distribution Equipment Index Page
|
|