COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 30,1997 PSA#1941NOAA/Systems Acquisition Office (SAO), 1315 E. W. Highway, Mail Code
SAOX2, Silver Spring, MD 20910 66 -- ALL-WEATHER PRECIPITATION ACCUMULATION GAUGE SOL 52-SPNA-8-00001
DUE 102097 POC Thomas D. Genovese, Jr., Contracting Officer,
(301-713-2110) The NOAA Automated Surface Observing System (ASOS)
program has a need for an All-Weather, Liquid and Frozen Precipitation
Water Equivalent Accumulation Gauge. An alternative to tipping bucket
technology is sought which meets the following performance
requirements: (1) Range (i.e., measuring capacity) greater than or
equal to 40 inches (mandatory), liquid water equivalent, unattended
(without user intervention); (2) Reporting Resolution of 0.01 inch. (3)
The accuracy of the gauge shall be linear over the entire measurement
range of temperature and wind, and shall meet the following
requirements for all precipitation rates (R): Accuracy of plus or minus
4 percent or plus or minus 0.02 inch, comparisons will be made on
hourly accumulations and event accumulations; (4) The gauge shall not
report any change in accumulation in the absence of precipitation. (5)
The gauge shall be fully compliant with accuracy requirements over the
following operational temperature limits: (a) low temperature
operational, minus 60 degrees F; (b) high temperature operational, plus
120 degrees F. Furthermore, the gauge shall survive exposure to the
following temperature extremes with no damage: (c) low temperature
withstanding, minus 80 degrees F; (d) high temperature withstanding,
plus 130 degrees F. (6) The gauge shall be fully compliant with
accuracy requirements over the following operational wind limits: (a)
Operational steady wind, up to 30 knots; (b) Operational wind gust, up
to 46 knots. Furthermore, the gauge shall survive exposure to the
following wind extremes with no damage: (c) Withstanding steady wind,
up to 73 knots; (d) Withstanding wind gust, up to 125 knots. (7)
Reliability, Maintainability, and Availability: (a) Mean Time Between
Failure, greater than or equal to 4,392 hours; (b) Periodic Maintenance
interval, not less than 90 days; (c) Mean Time to Repair, less than or
equal to 30 minutes; (d) Availability greater than or equal to
.9998861. Vendors may request a copy of the complete statement of work
(including design requirements) from the contact person within 2 weeks
of CBD issuance and should respond within 6 weeks of CBD issuance.
(0269) Loren Data Corp. http://www.ld.com (SYN# 0215 19970930\66-0021.SOL)
66 - Instruments and Laboratory Equipment Index Page
|
|