|
COMMERCE BUSINESS DAILY ISSUE OF SEPTEMBER 30,1997 PSA#1941U. S. Army Engineer District, Savannah, P.O. Box 889, Savannah, Georgia
31402-0889 C -- ALTER KC -135 FLIGHT SIMULATOR FACILITY, ROBINS AFB, GA SOL
DACA21-97-R-0074 POC Tim Corely -- 912/652-5420 WEB: Corps of
Engineers,Savannah District, Contracting,
http://www.sas.usace.army.mil. E-MAIL: Sandra Meyers,
sandra.b.meyers@sas02.usace.army.mil. The Savannah District U.S. Army
Corps of Engineers requires the services of an Architect-Engineer firm
for Design of Alter KC-135 Flight Simulator Facility, Robins AFB, GA.
The A-E will be required to provide site investigation, engineering
studies, concept preliminary and final design and construction phase
services to alter an existing 450 sm. KC-135 flight simulator facility.
This will be a firm fixed price contract. The contract is anticipated
to be awarded in November 1997 and completed in September 1998. The
construction cost range is $1,000,000 to $5,000,000. This announcement
is open to all firms regardless of size. For contracting information
call Sandy Meyers (912) 652-5324. **** 2. PROJECT INFORMATION: The
selected firm will be required to perform the following services: site
investigation, engineering studies, concept, preliminary and final
design, and construction phase services to alter an existing 450 sm.
KC-135 flight simulator facility. The alteration will require all
disciplines to allow the existing facility to accept a new full motion
simulator device. This will entail raising the height of the simulator
bay to accommodate the new simulator equipment. **** 3. SELECTION
CRITERIA: See Note 24 for general A-E selection process. The selection
criteria are listed below in descending order of importance (first by
major criteria and then by each sub-criterion). CRITERIA a-f are
primary. CRITERIA g-i are secondary and will only be used as
"tie-breakers" among technically equal firms. **** a. Specialized
Experience and technical competence in (1) Design of major building
renovation projects. (2) Design of flight simulator facilities (3) Use
of CADD and translation into Intergraph (4) Use of MCACES cost
estimating. **** b. Past performance on DoD and other contracts with
respect to cost control, quality of work and compliance with
performance schedules. **** c. Capacity to accomplish work in the
stated contract period and to provide the following disciplines:
architectural, structural, civil, electrical engineering, mechanical,
fire protection engineer, topographic surveyor and industrial
hygienist. NOTE: These disciplines must be shown in Block 4 of SF 255.
Please disregard the "to be utilized" statement at Block 4 of SF 255
and show the total strength of each discipline. **** d. Professional
Qualifications of key management and professional staff members. The
design team must include a Registered Fire Protection Engineer whose
principle duties are fire protection engineering or a Registered
Architect or Registered Engineer who is a full member in good standing
of the Society of Fire Protection Engineers (SFPE). **** e. Knowledge
of locality as it pertains in design and construction methods of
projects in the geographic area of this contract. **** f. Demonstrated
success in prescribing the use of recovered materials and achieving
waste reduction and energy efficiency in facility design. SECONDARY
CRITERIA. **** g. Extent of participation of Small Business (SB)
including Women Owned Small Business (WOSB), Small Disadvantaged
Business (SDB), historically black colleges and universities, and
minority institutions in the proposed team, measured as a percentage of
the total estimated effort. **** h. Proximity to the project site. ****
i. Volume of DoD contract awards in the last 12 months as described in
Note 24. **** 4. SUBMISSION REQUIREMENTS: See Note 24 for general
submission requirements. Interested firms having capabilities to
perform this work must submit ONE (1) copy of SF 255 (11/92 edition)
for prime and ONE (1) copy of SF 254 (11/92) for prime and all
consultants to the following address: US Army Engineer District,
Savannah, ATTN: CESAS-EN-EA, 100 W. Oglethorpe Avenue, Savannah, GA
31401-3640, not later than close of business the 30th day after the
date of this announcement. If the 30th day is a Saturday, Sunday, or
Holiday, the deadline is the close of business of the next business
day. NO FAXED SUBMITTALS WILL BE ACCEPTED. FIRMS MUST INCLUDE PRIME'S
ACASS NUMBER in BLOCK 3 of SF 255. For ACASS INFORMATION: Call
503/326-3459. Cover letters and extraneous materials (Brochures, etc.)
are not desired and will not be considered. The selected firm will be
required to submit a Design Quality Assurance Plan concurrently with
their fee proposal. PHONE CALLS ARE DISCOURAGED UNLESS ABSOLUTELY
NECESSARY. PERSONAL VISITS for the PURPOSE OF DISCUSSING THIS
announcement WILL NOT be SCHEDULED. This is NOT a REQUEST for a
PROPOSAL (0268) Loren Data Corp. http://www.ld.com (SYN# 0012 19970930\C-0006.SOL)
C - Architect and Engineering Services - Construction Index Page
|
|