COMMERCE BUSINESS DAILY ISSUE OF OCTOBER 28,1997 PSA#1960SOUTHWESTNAVFACENGCOM, 1220 Pacific Highway, San Diego, CA 92132-5187 Y -- MCON PROJECTS P-030, REPLACE BASILONE ROAD BRIDGE (PROJECT A),
AND MCON P-010, SANTA MARGARITA RIVER FLOOD CONTROL (PROJECT B), AT THE
MARINE CORPS BASE, CAMP PENDLETON, CALIFORNIA SOL N68711-97-R-8338 DUE
121297 POC Contract Specialist -- Mike Valdez (619)
532-1027/Contracting Officer -- Mark R. Schweer/For plans and
specifications call Plan Issue at (619) 532-2084. THIS NOTICE HEREBY
SUPERSEDES PREVIOUS NOTICE DATED SEPTEMBER 03, 1997, SUBMISSION NO.
117771. Sources sought to furnish all labor, approved materials and
equipment required for the following items of work. THE MAJORITY OF THE
WORK IS LOCATED IN AN ENVIRONMENTALLY SENSITIVE AREA. CONSTRUCTION WILL
OCCUR IN LOCATIONS WITH SEASONAL SURFACE WATER OR SHALLOW GROUNDWATER.
MCON P-030 (Project A) -- Work includes (a) demolition of an existing
temporary steel railroad car bridge and construction of a new
cast-in-place prestressed concrete bridge with pile foundations, (b)
construction of new approach roads and bridge abutments, with rock
slope protection and soil-cement revetment, (c) construction of a
remotely controlled traffic signal and relocation of existing airfield
lighting, and incidental related work. MCON P-010 (Project B) -- Work
includes (a) construction of a soil flood protection levee and
cast-in-place concrete floodwall. Specific portions of the levee may be
optionally constructed of reinforced earth with soil-cement revetment.
An existing earth levee shall be demolished and will provide some of
the materials for fill and rock slope protection for the new levee, (b)
construction of rock slope protection toe scour protection along the
levee and floodwall, (c) construction of a stormwater management system
consisting of collection system, earth and concrete ditches, and a pump
station with diesel engine -- and electric motor-driven pumps with an
automated control system, and incidental related work. -- Firm Fixed
Price Contract -- . Contract Duration is approximately 730 calendar
days. -- This project is unrestricted -. The Standard Industrial Code
is 1622 and the annual size standard is $17.0 million. It is
recommended that the subcontracting goals reflect a minimum goal of 5%
for Small Disadvantaged Businesses. This procurement is to be awarded
to the responsible offeror who submits the proposal most advantageous
to the Government considering the following evaluation factors: Price,
Past Performance, and Specialized Experience/Qualifications. The
following evaluation factors and subfactors shall be used to evaluate
the technical quality of the proposals. The factors and subfactors are
listed in order of importance. Elements within subfactors are of equal
importance. Factor 1 -- PRICE; Factor 2 -- PAST PERFORMANCE comprised
of the following subfactors 2.1 Delivering quality work in a timely
manner at a reasonable total cost as evidenced by previously completed
projects of similar scope and magnitude, 2.2 Effectiveness of
management and commitment to customer satisfaction, and 2.3 Degree of
satisfaction expressed by the customer when contacted.; Factor 3 --
SPECIALIZED EXPERIENCE/QUALIFICATIONS comprised of the following
subfactors 3.1 The number and quality of projects completed in the past
ten (10) years, with scope, magnitude, complexity and cost similar to
the requirements in this RFP, 3.2 Specialized experience and
qualifications of key personnel proposed, and 3.3 Capacity to perform
within the required schedule. SITE VISIT IS SCHEDULED ON NOVEMBER 24,
1997, with participants to meet at 9:00 am at the ROICC Office, Bldg.
22101, Marine Corps Base, Camp Pendleton, California. A PRE-PROPOSAL
CONFERENCE IS SCHEDULED ON NOVEMBER 25, 1997, at 9:00 am, with
participants to meet at Southwest Division, Naval Facilities
Engineering Command, 1220 Pacific Highway, San Diego, California. THIS
IS NOT A PUBLIC BID OPENING. The estimated cost is between $10,000,000
and $25,000,000. NOTE -- plans and specifications will NOT be mailed to
firms within a 20 mile radius of the local San Diego area. Requests for
solicitation packages must be in writing stating RFP number
N68711-97-R-8338, with complete name, address, area code and phone
number, and whether bidding as a prime/subcontractor/supplier.
Solicitation packages may be personally acquired from Plan Issue or by
mail. Mail requests to Southwest Division, Naval Facilities
Engineering Command (Plan Issue), 1220 Pacific Highway, Building 132,
San Diego, CA 92132-5187. Telephone requests will NOT be accepted.
Solicitation packages are limited to two (2) sets per prime and one (1)
set per subcontractor/supplier. There will be a charge for plans and
specifications yet to be determined. Contact Plan Issue at (619)
532-1027 to obtain this cost. FEES FOR PLANS AND SPECIFICATIONS ARE NOT
REFUNDABLE. PLANS AND SPECIFICATIONS WILL BE AVAILABLE ON OR ABOUT
NOVEMBER 12, 1997. The only acceptable methods of payment for plans and
specifications are via, mastercard, cashiers checks or money orders
made payable to DEFENSE PRINTING SERVICE. Plan Holders Lists will NOT
be faxed. (0297) Loren Data Corp. http://www.ld.com (SYN# 0095 19971028\Y-0017.SOL)
Y - Construction of Structures and Facilities Index Page
|
|