COMMERCE BUSINESS DAILY ISSUE OF NOVEMBER 10,1997 PSA#1969US Bureau of Reclamation, Code 7810, PO Box 620, Grand Coulee, WA
99133 61 -- PLANTE CELL BATTERIES AND RACKS SOL 1425-97-SQ-17-14600 DUE
120597 POC Nora E. Jenn (509) 633-9509 E-MAIL: Plante cell batteries,
njenn@pn.usbr.gov. This is a combined synopsis/solicitation for
commercial items prepared in accordance with the format FAR Subpart
12.6, as supplemented with additional information included in this
notice. This announcement constitutes the only solicitation; quotes are
being requested and a written solicitation will not be issued.
Solicitation No. 1425-97-17-14600 is issued as a Request for Quotation
(RFQ) and incorporates provisions and clauses in effect through
Federal Acquisition Circular 90-46. This acquisition is not a
set-aside. The size standard is 500 employees and the standard
industrial classification code is 3691. U S Bureau of Reclamation,
Grand Coulee Washington has a fixed price requirement for the following
items in accordance with the specifications herewith: Requirements for
3PP Battery A in accordance with the following specifications: A.
Plante type cells with cast, solid, pure lead positive. Pasted-plate or
grid type positive plates will not be allowed. The negative platesshall
be the pasted-grid type. B. The cell posts shall be configured such
that the intercell connectors are of the dual independent type. This
post and connector design shall allow for the removal of any one of the
parallel dual intercell connectors for maintenance/replacement while
the battery remains in service. C. The cell jars shall be of a clear,
fire-resistant material such as styrene acrylonitrile (SAN), to
facilitate visual inspection. The jar lids shall be chemically welded
to the jars using a tongue and groove joint. D. The post seals shall be
a tongue and groove rubber system held captive in the lid. This seal
shall allow for the normal elongation of the plates without
deterioration of seal integrity. E. The Plante type cells shall retain
100 percent of rated capacity throughout the life of the battery. The
rated life expectancy of the battery shall be at least 25 years. F.
Each cell shall be fitted with a flame arrector vent cap. The cells
shall be Alcad, Type SGH-31, or equal. The battery must meet the
specifications shown above. CLIN0001 -- Battery, Plante type, station
type, consisting of 58 individually cased lead acid cells, nominally
rated 125 VDC; rated 1,730 amp-hours on the 8-hour rating when
discharged to a minimum of 1.75 volts per cell. The battery shall meet
the specifications shown previously for 3PP Battery A. Alcad Model
SGH-31, or equal. -- 1 lot; CLIN0002 -- Rack, battery, for the
batteries supplied under CLIN0001. The rack shall be in three sections;
two at 15 foot and one at 14 foot respectively. The rack shall be of
the two-step type, seismically rated to meet the requirements of
Uniform Building Code Seismic Zone 4. Two each of Alcad Models
RM2S-15EQ and one each of Alcad Model RM2S-E14EQ, or equal -- 1 lot;
CLIN0003 -- Connector, intercell -- The supplier shall provide all
necessary intercell connectors for the complete installation of
CLIN0001 onto the racks (CLIN0002). The intercell connectors shall be
the dual independent type, such that the battery can remain in service
with one of the dual connectors removed; also, supplier shall furnish
connectors equal to 20 percent of those required above for spare parts
-- 1 lot; CLIN0004 -- Grease, non-oxidizing connection compound for use
in installation of CLIN0001, plus additional grease in the same amount,
to be kept on hand for stock -- 1 lot; CLIN0005 -- Jumpers, typical for
this battery and rack. An additional two jumpers of three foot and six
foot are also required; CLIN0006 -- Provide the Government with a
disposal company with service to the Grand Coulee Dam Washington area
which would provide disposal of the existing 60 cell lead acid station
batteries in accordance with all Federal and Washington state
regulations; and who will furnish certified documentation of the
disposal of the existing batteries in conformance with regulations --
1 each. The successful low bidder will be responsible for the disposal
of the existing batteries. The items must be delivered to U S Bureau
of Reclamation, Warehouse B -- Door 6, Industrial Area, Grand Coulee WA
99133 by February 6, 1998. The following FAR provisions and clauses
apply to this acquisition: 52.212-1 Instructions to Offerors --
Commercial Items (JUN 97), 52.212-3 Offeror Representations and
Certifications -- Commercial Items (JAN 97), 52.212-4 Contract Terms
and Conditions -- Commercial Items (MAY 97), 52.212-5 Contract Terms
and Conditions Required to Implement Statutes or Executive Orders --
Commercial Items (AUG 96), and 52.247-34 F.O.B. Destination (NOV 91).
Clause 52.212-5, paragraph (b) is tailored to incorporate the following
clauses by reference: 52.222-26, 52.222-35, 52.222-36, 52.222-37, and
52.225-18. The Government intends to make a single award to the
responsible bidder whose bid is most advantageous to the Government,
based on items meeting the specification, delivery schedule, and price
and price-related factors considered indescending order of importance
as listed here. The closing date for receipt of offers is December 5,
1997. Offers are to be mailed to the following address: Bureau of
Reclamation, Code 7810, P O Box 620, Grand Coulee WA 99133-0620. All
sources responding to this Request for Quotation shall do so in
writing. All sources responding to this synopsis shall submit
information relating to business status, including identification as to
whether small, large, minority-owned, and/or women-owned. Include
Federal Tax Identification number and DUNS number on your bid. All
responsible sources may submit a bid, which will be considered by this
agency. (0309) Loren Data Corp. http://www.ld.com (SYN# 0216 19971110\61-0001.SOL)
61 - Electric Wire and Power and Distribution Equipment Index Page
|
|