COMMERCE BUSINESS DAILY ISSUE OF DECEMBER 2,1997 PSA#1983Operational Contracting, ESC/PKOP, 104 Barksdale Street, Hanscom AFB,
MA 01731-1806 66 -- ATMOSPHERIC METEOROLOGICAL MEASUREMENTS SYSTEM SOL
F19650-97-Q8116 POC SrA Jerry M. Tanner, Contracting Specialist,
(781)377-3362; Rhonda J. Chavez, Contracting Officer, (781)377-2236
WEB: Electronic Systems Center Business Opportunities Page,
http://www.herbb.hanscom.af.mil. E-MAIL: Buyer's email address,
tannerj@hanscom.af.mil. The Operational Contracting Office, Services
Branch, Hanscom AFB, MA is seeking potential sources for the following
equipment and services for information and planning purposes only.
This synopsis does not constitute a request for proposal, and is not
considered to be a commitment by the government. The meteorological
system will be used to obtain Atmospheric Pressure, Temperature,
Humidity, Wind Speed and Direction from 0 Kilometers to 30 Kilometers
in altitude using a balloon borne meteorological instrument in
conjunction with a ground station to receive and process the data. Five
spare channels will be required for transmission of data from sensors
used for scientific investigation of atmospheric parameters by
scientist at Phillips Laboratory. The spare channels will be required
to convert volts or microamps of current to counts upon reception of
data so that the final data, in engineering units, can be obtained
easily from the users calibration and the channel calibration. Any
drift in channel datado to the large change in atmospheric temperature
should be compensated for. The ground station system will receive,
process and display, in real time, all data from the radiosonde to
include the customers five spare channels of data. A graphics software
computer interface package will be supplied along with the necessary
cables to connect the ground station to an IBM compatible computer as
a Windows 95 application. The software will provide the capability of
down loading ASCII files of all data upon completion of flight. This
system will not include the purchase of a computer. The government will
furnish the computer. The radiosonde used in conjunction with the
ground station is required to be an operational, off the shelf item.
Other features required are as follows: a) Wind measurements are to be
obtained using the Global Positioning System (GPS) satellite
constellation. Winds accurate to 0.2 to 0.5 meters/sec with vertical
resolution of between 30 to 50 meters. b) Measurement Range and
Resolution: Pressure -- 1060 to 3 millibars with 0.1 millibar
resolution Temperature -- +60 to -90 Deg C with 0.1 Deg resolution
Humidity -- 0 to 100% RH with 1% RH resolution Wind Speed -- 0 to 180
m/s with 0.1 m/s resolution Wind Direction- 1 to 360 degrees with 1
degree resolution Wind Vector Accuracy: 0.5 to 0.2 meters/sec GPS
Sampling rates of pressure, temperature, humidity and spare channels
required to be in range of 0.5 to 2.5 sec. c) Frequency range 400 to
406 Mhz Carrier with FM modulation. Antenna to include, local GPS and
UHF lobe switching, directional, solid state antenna. 200 Km minimum
Telemetry Range is required. System will have automatic frequency
search and lock-on as well as automatic direction search of the
received signal. d) Must have graphics software with flexibility in
changing scales and labeling graphs of all data in real time plots. e)
The radiosonde package must be 500 grams or less including wet cell
battery and have dimensions within + or -- 2cm, excluding antenna, as
follows: L=15cm, W=7cm, and H=20cm, to allow proper ascending to 30
kilometers using a 1200 gram balloon. f) The radiosonde must withstand
52 degrees C on the ground and -- 85 Degrees C near the Tropopause
region of the atmosphere. All respondents that can provide the above
listed equipment and services should reply in writing within 20 days of
this publication to SrA Jerry M. Tanner, ESC/PKOP, Operational
Contracting, 104 Barksdale Street, Hanscom AFB, MA 01731-1806. (0332) Loren Data Corp. http://www.ld.com (SYN# 0105 19971202\66-0013.SOL)